GAGGIA CADORNA
01 INTRODUCTION
1/6
1.1. Specific tools and equipment
As well as the standard equipment, the following is required:
12NC
Description
Notes
-
Flathead screwdriver
# 0, # 2
-
Torx screwdriver
(T10,T20)
-
Cutter
-
Cable tie tightening tool
-
Pliers for Oetiker clamps
-
Digital Thermometer
Type K (accuracy for temperature of 0,05 % or ± 0,3°C)
-
Temperature probe
80PK-22 (80AK-A Thermocouple adapter required)
-
Scale
KERN EMB 500-1 or comparable device with a base
accuracy of 0,05 % or ± 0,5 g
-
Power meter
Voltcraft EnergyCheck 3000 or comparable device with
a base accuracy of 1 % or ± 5W
-
Stopwatch
Basic model
996530009845 Serkit
Tool needed for programming with our service tool
1.2. Maintenance Products
12NC Code
Material
Description
-
Thermal paste
Heat resistance > 200°C
996530067222 Descaler
“ACC SAE DECALCIFIER 5 L 1 UNIT”
132253695601 Jar of Grease
“PARALIQ GB 363”
996530045784 Silicone grease
“ACC TUBE FIN FOOD GREASE 2 400 ML”
1.3. Safety warnings
Please, read the Service manual of the machine before starting any maintenance.
Operation, maintenance and/or repair of this device has to be carried out only by qualified persons, trained
for work at or with electric devices.
During the machine disassembly the operator has to pay attention to hot and under pressure parts.
All parts involved can be find in the hydraulic circuit below schema.
The machine hydraulic circuit can reach maximum pressure of 16/18 bar.
When the machine arrives at the Service Center in descaling mode interrupted, or making Descaling , take
EXTREME CARE to avoid any unintentional contacts with the descaler.
After the product has been repaired, it should function properly and has to meet the safety requirements and
legal regulations as officially laid down at this moment.
The technicians to operate under safety conditions, needs to:
1. Use personal safety devices;
2. Disconnect the appliance from the power mains before repairing;
3. Before and after repair, it is recommended to perform dielectric strength tests (This domestic
appliance is rated as insulation class 1).
Содержание SUP 049EU
Страница 4: ...GAGGIA CADORNA CHAPTER 1 INTRODUCTION...
Страница 7: ...GAGGIA CADORNA 01 INTRODUCTION 3 6 1 5 Electrical diagram...
Страница 11: ...GAGGIA CADORNA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Страница 16: ...GAGGIA CADORNA CHAPTER 3 OPERATING LOGIC...
Страница 23: ...GAGGIA CADORNA CHAPTER 4 TEST MODE AND STEAM OUT...
Страница 29: ...GAGGIA CADORNA CHAPTER 5 ESPRESSO PHILIPS SERVICE CENTER...
Страница 31: ...GAGGIA CADORNA CHAPTER 6 MACHINE REPAIR FLOW...
Страница 33: ...GAGGIA CADORNA CHAPTER 7 DISASSEMBLY...