6.6 Solenoid pilot
Brew
group
drain valve
Drain
Brew group valve
(3 - 5 bars)
Needle
Solenoid pilot function:
1.
Brew group drain:
before the group is lowered, the solenoid pilot opens briefly creating a depression
that in turn opens the valve in the opposite direction from dispensing, allowing any
water left in the group to be drained and keeping the pad dry.
2.
Coffee ready after steam:
when a coffee or water are selected, the solenoid pilot opens the drain valve
to lower pressure in the heater.
3.
Prime heater:
after a period in standby or when the appliance has not been used for an extended period
(1st coffee), the pump loads briefly during grinding to get rid of any water between the
heater pin and heater, and to pre-heat the elements.
4.
Fill circuit:
the solenoid pilot discharges and recharges automatically. The discharge occurs via the drain
pipe and not via the valve.
5
.
Relief valve:
the solenoid pilot also serves as a relief valve (not present on pump), opening in the event
of pressure in excess of 16-19 bars.
6.
Lower pressure:
pressure is lowered by the circuit being discharged for 10 seconds after water or steam
have been dispensed (see variables A and B).
A)
Configuration with dual-sensor valve card (water/steam position Milk Island posi-
tion sensor):
After water has been dispensed - > the solenoid pilot opens to the discharge side as soon as the sensor is
disengaged.
Immediately after steam has been dispensed - > the solenoid pilot opens to the discharge side as soon as
the sensor is disengaged.
Water dispensed after steam has been dispensed -> the solenoid pilot opens to the discharge side as soon
as the sensor is disengaged.
- After each beverage has been dispensed -> the solenoid pilot opens to the discharge side.
- Each time the appliance is switched on and the temperature is reached -> the solenoid pilot opens to the
discharge side.
- When the temperature is reached -> the solenoid pilot opens to the discharge side.
B)
Configuration with three-sensor valve card (water/steam closed position
milk island position sensor):
In addition to the functions described in configuration A, the following also occur:
Each time the closed position central sensor is disengaged -> always open the solenoid pilot towards the
discharge side.
Turbine
Steam tube
Silicon tube
TANK
Silicon tube
Pump
Silicon tube
Reinforced silicon hose
Reinforced silicon hose
Reinforced silicon hose
Reinforced silicon hose
Reinforced silicon hose
STEAM/WATER
DISPENSE
1300W heater
WATER DRAINED
TO DRIP TRAY
Water drain connector
Water/steam valve
Water drain connector
WATER DRAINED
TO TANK
COFFEE
DISPENSE
SBS valve
Connector with 3 bar relief valve
MILK ISLAND STEAM
DISPENSE
Brew unit
Brew unit pin
Coffee dispense valve (3-5 bars)
Drain valve
Relief valve (16-19 bars)
Содержание PLATINUM EVENT
Страница 1: ...Emissione Luglio 2007 REV 00 TECHNICAL SERVICE MANUAL ...
Страница 3: ...SECTION 1 INTRODUCTION REV 00 TALEA Section 01 REV00 August 06 ...
Страница 6: ...EVENT S B S Rapid Steam TALEA ODEA Cap 01 REV00 Luglio 07 3 3 ...
Страница 7: ...SECTION 2 TECHNICAL DATA REV 00 TALEA Section 02 REV00 August 06 ...
Страница 10: ...Ideas with Passion SECTION 3 BRIEF INSTRUCTIONS REV 00 TALEA Section 03 REV00 August 06 ...
Страница 14: ...Ideas with Passion SECTION 4 DIAGRAMS REV 00 TALEA Section 04 REV00 August 06 ...
Страница 37: ...SECTION 6 OPERATING LOGIC REV 00 TALEA Section 06 REV00 August 06 ...
Страница 45: ...Ideas with Passion SECTION 7 COMPONENT ASSEMBLY AND DISASSEMBLY REV 00 TALEA Section 07 REV00 August 06 ...
Страница 58: ...Ideas with Passion SECTION 8 SERVICE SCHEDULE REV 00 TALEA Section 08 REV00 August 06 ...