WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

a.) Use this unit only in the manner intended by the

manufacturer. If you have questions, contact 
the manufacturer.

b.) Before servicing or cleaning unit, switch power

off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.

CAUTION:

FOR GENERAL VENTILATION USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.

WARNING - TO REDUCE THE RISK OF A
RANGE TOP GREASE FIRE. 

a.) Never leave surface units unattended at high

settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low
or medium settings.

b.) Always turn hood ON when cooking at high heat

or when cooking flaming foods.

c.) Clean ventilating fans frequently. Grease should

not be allowed to accumulate on fan or filter.

d.) Use proper pan size. Always use cookware

appropriate for the size of the surface element.

WARNING - TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE
FOLLOWING:

a.) SMOTHER FLAMES with a close-fitting lid,

cookie sheet, or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.

b.) NEVER PICK UP A FLAMING PAN - You may be

burned.

c.) DO NOT USE WATER, including wet dishcloth or

towels - a violent steam explosion will result.

d.) Use an extinguisher ONLY if:

1. You know you have Class ABC extinguisher, 

and you already know how to operate it.

2. The fire is small and contained in the area 

where it started.

3. The fire department is being called.

4. You can fight the fire with your back to an exit.

Safety notes

3

Read And Save These Instructions.

All manuals and user guides at all-guides.com

Содержание VL040-707

Страница 1: ...Operating and assembly instructions VL 040 041 707 Hob ventilator 0 1 2 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...r your safety Page 4 1 2 Operating for the first time Page 5 2 Structure and operating principle Page 6 2 1 Structure of the appliance Page 6 2 2 Accessories Page 6 3 Operation Page 7 4 Cleaning and c...

Страница 3: ...nstructions contain important notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your per...

Страница 4: ...en cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropri...

Страница 5: ...this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be deenergised by means of the domestic installation fuse In the event of malfunctio...

Страница 6: ...as your operating and assembly instructions You need the rating plate for possible damage and warranty cases Remove the packaging from the appliance and dispose of it properly Pay attention to the fac...

Страница 7: ...tion extraction connection Special accessories AS 070 000 connection piece for extension during assembly fig 4 VV 200 000 connecting trim RV 050 150 bifurcated pipe for joining 2 x DN 125 into DN 150...

Страница 8: ...hob ventilators That is to say if you set the control knob to level 1 both hob ventilators are operated at level 1 Switching on Turn the control knob to the right to the position you require 0 2 Swit...

Страница 9: ...tilation grille Turn up the two retaining wires and detach the grease filter from the appliance Insert in the reverse order The appliance must be disconnected from the power supply during all repair w...

Страница 10: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning ASHRAE and the local code authorities c...

Страница 11: ...es not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall...

Страница 12: ...nward Proceed as follows to establish a blow out opening at the side Undo all 5 screws on the connection piece and detach the connection piece Undo the screws of the side cover Screw the connection pi...

Страница 13: ...in the screw Connect the hob ventilator to the fan module by means of the 4 pole plug Pay particular attention to ensuring that the exhaust air ducts are kept as short as possible the pipes are not l...

Страница 14: ...3 6027 93ind02 en 03 03 SK 13 All manuals and user guides at all guides com...

Страница 15: ...TINGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau usa com GAGGENAU HAUSGER TE GMBH P O BOX 10 02 50 80076 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 All manuals and user...

Отзывы: