142_58300000122107_ara_en_b.doc – 02.02.09
Seite 15 von 16
7.2
Plastic hose is twisting
Fault description:
¾
The swivel arm can no longer be extended. (mechanically
blocked)
Cause of fault:
¾
The plastic hose has become so twisted that the swivel arm
is blocked.
Troubleshooting:
¾
Remove the appliance, loosen the pipe clip and fit plastic hose
without twisting it.
7.3
Too little air power
Complaint:
¾
Extraction is too weak or the fumes go past the extraction arm.
Cause:
¾
Units VL 051 and GB 031 have a free-blowing air power
of 350 m³/h. (See performance characteristic)
Additional pipelines reduce the power further. Flat ducts are
unsatisfactory as regards air flow and should not be used.
¾
The intake area of the swivel arm is very small in comparison
with a hood. Depending on the position of the hob, not all fumes
are detected.
Rectification:
¾
Check direction of rotation of the fan.
Viewing the intake connection
from above, the fan impeller must
rotate in a clockwise direction.
¾
Check pipe installation. If pipelines are long or flat ducting is
used, the air power is reduced considerably.
Содержание VL 051-107
Страница 4: ...142_58300000122107_ara_en_b doc 02 02 09 Seite 4 von 16 2 1 1 Installing retaining clamp...
Страница 5: ...142_58300000122107_ara_en_b doc 02 02 09 Seite 5 von 16 2 2 Installation position 1...
Страница 6: ...142_58300000122107_ara_en_b doc 02 02 09 Seite 6 von 16 2 3 Installation position 2...
Страница 7: ...142_58300000122107_ara_en_b doc 02 02 09 Seite 7 von 16 2 4 Installation position 3...
Страница 13: ...142_58300000122107_ara_en_b doc 02 02 09 Seite 13 von 16 5 FUNCTIONS 6 REPAIR There are no error messages...