17
Technical data (gas)
Burners: Normal
burner
Full burning
7,000 BTU (2 kW)
Low burning
700 BTU (0.175 kW)
Large burner
Full burning
13,500 BTU (4 kW)
Low burning
700 BTU (0.175 kW)
Gas connection:
R 1/2’’ union nut for R 1/2’’
bracket to DIN 1999, conical-cylindrical
Technical data (electrical)
Rated consumption
15 W
Voltage
AC 120 V
Frequency
60 Hz
Technical modifications reserved.
12. Technical Data / Nozzle Table
Nozzle, full burn, outer
1.50
1.05
Nozzle, low burn, outer
0.65
0.45
Nozzle, full burn, inner
0.40
0.29
Nozzle, low burn, inner
0.42
0.28
Air gap adjustm. outer [mm]
0
2
Air gap adjustm. inner [mm]
open, fixed
open, fixed
Countries
US CA
US CA
Gas family
Natural gas
LPG/Prop.
Pressure
6” W.C. (1.5 kPa)
10” W.C. (2.5 kPa)
Total output
20,500 BTU (6 kW)
20,500 BTU (6 kW)
Nozzle table large burner
Nozzle, full burn, outer
0.97
0.68
Nozzle, low burn, outer
0.48
0.34
Nozzle, full burn, inner
0.40
0.29
Nozzle, low burn, inner
0.42
0.28
Air gap adjustm. outer [mm]
0
open at maximum
Air gap adjustm. inner [mm]
open, fixed
open, fixed
Nozzle table small burner