22
Electrical Connection
Electrical connection (AC 110-127 V) is established
by means of a connecting cable with a grounding
contact plug connected to a grounded socket,
which must also be accessible after installation of
the gas hob.
If, after installation of the gas hob, not all poles can
be isolated from the power by removing the plug,
an isolating device with a contact gap of at least
3 mm must be permanently installed. When estab-
lishing connections, make sure that the connecting
lead cannot come into contact with hot parts of the
gas hob or other hot parts.
Warning:
this appliance is equipped with a three prong
grounding plug for your protection against shock
hazard and should be plugged directly into a pro-
perly grounded receptacle. Do not cut or remove
the grounding prong from this plug.
The mains connecting cable must at least
correspond to type SJT 3x18 AWG/UL/CSA or it
must be correspondingly heat-resistant (at least
105 °C).
The mains connecting cable must only be
purchased through and connected by an
authorised specialist.
G
floor
8-12” (200-300 mm)
24” (610 mm)
max 8”
(210 mm)