Electrical connection
Check that the appliance has the same voltage and frequency
as the electrical installation system.
The hob is delivered with a mains cable, with or without plug,
depending on model.
Only connect the appliance to sockets which have been fitted
and earthed according to regulations.
The appliance corresponds to type Y: the mains connection
cable must only be replaced by the after-sales service. Check
the cable type and minimum cross section.
Technical data / nozzle table
Total connected load town gas 3.3 kW / 2.2 kW
Total connected load LPG 2.8 kW / 1.9 kW
Total connected load electric 0.8 VA
Nozzle table
Conversion to another type of gas
This gas hob corresponds to the categories specified on the
rating plate. It is possible to convert the appliance to any of the
gases listed on the plate by changing the nozzles. The
modification kit can be ordered via our after-sales service.
Depending on the model the parts required may beincluded in
the scope of delivery.
The conversion must be carried out by a licensed and trained
technician.
Before carrying out the conversion, turn off the electricity and
gas supply.
Changing the low burn nozzle – fig. 5:
1.
Remove the cover from the underside of the appliance under
the gas valves. The low burn nozzle is located in the gas valve
and is screwed in from below.
2.
Unscrew the nozzle and insert the new nozzle as specified in
the low-setting nozzle table. The nozzle must be screwed in
fully.
3.
Fit the cover cap again.
Changing the full burn nozzle – fig. 6:
1.
Remove the pan supports and burner lids.
2.
Change the nozzles. A suitable spanner can be obtained via
our after-sales service (ordering code 00424699). Care should
be taken to ensure that the nozzles do not break off when
screwed in or out.
3.
Screw the new nozzles in as far as they will go to achieve a
good seal.
4.
Replace the pan supports and burner lids, checking that they
are correctly positioned.
If it should be necessary to correct the low-setting nozzle as the
result of deviating gas types and pressure, the flow rate can be
increased by turning to the left.
These burners do not require the primary air to be adjusted.
Checking functions after the conversion:
The flames are adjusted correctly if no yellow tips are visible
and if they do not go out when switching over swiftly from the
high to the low setting.
Note:
stick the adhesive label included with the nozzle set over
the rating plate of the appliance to document the changeover to
a different gas type.
Gas
Town Gas [HK SG]
LPG [HK SG]
Pressure
10 mbar
29 mbar
A-burner full burn
205
68
A-burner low burn
47 gap*
30
B-burner full burn
270
85
B-burner low burn
55 gap*
36
Total connected load 3.3 kW / 2.2 kW
2.8 kW / 1.9 kW
Total consumption
1.18 m³/h
358 g/h
* ½ turn