Technical data (gas)

Burners: 

Normal burner

Full burning

6500 BTU (1.90 kW)

Low burning

< 1400 BTU (0.41 kW)

High-intensity burner

Full burning

9500 BTU (2.8 kW) 

Low burning

< 1900 BTU (0.56 kW) 

Gas connection:

R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical

Settings table, gas

Technical data (electrical)

Rated consumption 

0.8 W

Voltage

AC 120 V

Frequency 

60 Hz

Technical modifications reserved.

12

6. Technical data / Settings table

Countries

USUS

CA

CA

Gas family

Natural gas

Propane gas

Gas type

A

E

Pressure

6” W.C. (1.5 kPa)

10” W.C. (2.5 kPa)

A burner, full burning

0.94

0.74

A burner, low burning

0.49

0.36

B burner, full burning

1.28

0.87

B burner, low burning

0.58

0.42

∑ Power

16 000 BTU (4.7 kW)

16 000 BTU (4.7 kW)

∑ Consumption

0.45 m

3

/h

340 g/h

Содержание VG 232 CA

Страница 1: ...Operating and assembly instructions VG 232 CA Gas cooker...

Страница 2: ...age 5 1 3 About use Page 6 2 Structure and operating principle Page 7 8 2 1 Structure Page 7 2 2 Special accessories Page 7 2 3 Operating principle Page 8 3 Operation Page 9 4 Cleaning and care Page 1...

Страница 3: ...r any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a n...

Страница 4: ...any parts in counter top wood plastic or other non heat resistant materials Never leave oil or hot fat unattended Note To avoid jeopardising the electrical safety of the appliance it is forbidden to...

Страница 5: ...and assembly instructions conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance You will find notes on pa...

Страница 6: ...uring every maintenance operation To do this remove the mains plug or actuate the corresponding fuse Close the gas supply Repairs must be carried out by authorised specia lists thus ensuring electrica...

Страница 7: ...k of burns when working next to naked flames you also save gas and reduce pollution Whenever the gas hob is fitted under a vapour extractor hood always cover the rings with pots or pans Otherwise part...

Страница 8: ...nob for the rear cooking position 6 Burner cover 7 Burner head 8 Spark plug for automatic ignition 9 Thermal sensor for flame monitor You can order the following special accessories VV 200 000 Connect...

Страница 9: ...16000 BTU 4 7 kW referred to Hs gross calorific value 14300 BTU 4 2 kW referred to Hi calorific value The specified rated load is defined by installation of the fixed nozzles The gas hob is converted...

Страница 10: ...conds turn the control knob further to the left to the low position and then back to the high position after ignition It is often faster to ignite in the low position because the various gases have a...

Страница 11: ...moist cloth Soak burnt in remainders in a little water and detergent This loosens even the most stubborn of soiling Do not use any abrasive agents and abrasive sponges As the result of heat developme...

Страница 12: ...horised technicians in order to guarantee the safety of the appliance Unauthorised tampering with the appliance will invalidate any warranty claims Only ever use original spare parts 11 5 Maintenance...

Страница 13: ...s table gas Technical data electrical Rated consumption 0 8 W Voltage AC 120 V Frequency 60 Hz Technical modifications reserved 12 6 Technical data Settings table Countries US US CA CA Gas family Natu...

Страница 14: ...551 McFADDEN AVENUE HUNTINGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau usa com GAGGENAU HAUSGER TE GMBH P O BOX 10 02 50 80076 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 4...

Отзывы: