Gaggenau VG 231 AU Скачать руководство пользователя страница 15

8.1 Important notes  

Please observe the 

safety notes

and the

important notes

(Chapter 1).

The installer

is responsible for perfect functioning

of the appliance at its installation location.
He must explain the operating principle to the user
with reference to the operating instructions and
must show how to switch of the electricity and gas
whenever required.

Caution:

Before connecting the appliance, please check
whether the

local connection conditions 

such as

the gas type, gas pressure and mains voltage and
the appliance settings are correct. Refer to the
adhesive label on the gas connection or the

rating

plate

for the necessary information. This gas hob

conforms to the categories that are specified on 
the rating plate. The rating plate can be found on
the appliance and additionally on the enclosed
addendum sheet. By replacing nozzles, it is
possible to set the appliance to any gas listed on
the rating plate. If the data should not agree, the
appliance must be set to the required gas type and
the available pressure.
As this gas hob is not intended for connection to an
exhaust gas system, pay attention to the applicable
installation conditions.

Note on ventilation:

To ensure good combustion, the room in which this
appliance is installed must have a minimum volume
of 10 m

3

and a door that opens out to outdoors or a

window that can be opened.

Warning:

This appliance shall only be installed by an
authorized person.

The appliance shall be installed in accordance with
the manufacturer’s Installation Instructions, local
Gas Fitting Regulations, Municipal Building Codes,
the A.G. A. Installation Code for Gas Burning
Appliances, the S.A. A. Wiring Code, local Electric
Authority Regulations and any other statutory
regulations.

The appliance 

may be installed in kitchen

combinations made of wood or similar combustible
materials without taking additional measures.  

A minimum clearance of 260 mm 

from the

periphery of the burner to a rear or side horizontal
combustible surface must be observed. 

If clearance is less than 260 mm 

then that

surface must be protected in accordance with
clause 5.12.1.2 of AG601-98.

Overhead clearances

Rangehoods and exhaust fans shall be installed in
accordance with the manufacturers instructions.
However, in no case shall the clearance between
the highest part of the burner and the underside of
the rangehood be less than

600 mm 

or for a

overhead exhaust fan,

750 mm

.

After unpacking, check the appliance for any
transportation damage and report this immediately
to the transportation company.

Technical modifications reserved.

15

8. Assembly instructions

Содержание VG 231 AU

Страница 1: ...le Page 8 3 Operation Page 9 4 Cleaning and care Page 10 5 Maintenance Page 11 5 1 General Page 11 5 2 Remedying slight malfunctions yourself Page 11 6 Technical data Table Page 12 7 Practical tips Pa...

Страница 2: ...this appliance Do not spray aerosols in the vicinity of this appliance while it is in operation WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not...

Страница 3: ...connected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 3 5 kPa 1 2 psig The appliance must be isolated from the gas supply piping system b...

Страница 4: ...and assembly instructions conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance You will find notes on pa...

Страница 5: ...circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or isolate the corresponding fuse Close the gas supply Repairs must be carried out by...

Страница 6: ...ing whenever you remove pots or pans briefly thus saving gas and reducing pollution Whenever the gas hob is fitted under a vapour extractor hood always cover the rings with pots or pans Otherwise part...

Страница 7: ...l sensor for flame monitor 4 Pot support 5 Control knob for the cooking position 6 Burner cover 7 Burner ring 8 Burner head recess 9 Burner head You can order the following special accessories VV 200...

Страница 8: ...to a different gas type by nozzle replacement full and low burning nozzles see nozzle table The symbols on the control panel mean 0 Off High position of outer and inner flame rings Low position of ou...

Страница 9: ...er to the left to the low position and then back to the high position after ignition It is often faster to ignite in the low position because the various gases have a differing ignition response Once...

Страница 10: ...water and detergent This loosens even the most stubborn of soiling Do not use any abrasive agents and abrasive sponges As the result of heat development slight dis coloration can appear on the stainl...

Страница 11: ...operation is indicated In that case call Sampford Staff Pty Ltd 421 Smith Street Fitzroy Vic 3065 Tel 03 9418 5888 Service Centres in other States Melbourne Y 03 9418 5888 Sydney Y 02 9331 8888 Adelai...

Страница 12: ...Technical data gas Technical data electrical Rated consumption 0 8 W Voltage 220 240 V Frequency 50 60 Hz Technical modifications reserved 6 Technical data Table Countries AU AU Gas family Natural gas...

Страница 13: ...cooked as briefly as possible under strong heat and constant stirring In the large round pan everything can be stirred and turned faster and with greater ease than in a conventional frying pan Thanks...

Страница 14: ...same time Briefly roast the garlic and ginger and add the meat cubes Reduce the heat Add the Tongku and oyster mushrooms spring onions oyster and fish sauce and the sugar and allow to cook for about...

Страница 15: ...ustion the room in which this appliance is installed must have a minimum volume of 10 m3 and a door that opens out to outdoors or a window that can be opened Warning This appliance shall only be insta...

Страница 16: ...ot permitted Electrical connection The appliance is connected to the mains 240 V AC by means of the connecting lead with the earthed plug It must be plugged into an earthed socket which remains access...

Страница 17: ...er head If the appliance is connected rigidly to a gas main it must be disconnected from the gas network If it is connected via a gas safety hose the appliance only needs to be pushed out of its mount...

Страница 18: ...gas leaks on the installed main nozzle According to the new gas type stick the included adhesive label over the data specified on the gas connection Adjust the air gap according to the table entitled...

Страница 19: ...e flames burn stably and with low noise Yellow tips must not be visible in the flames The flame must not go off when you switch swiftly from the high to the low setting Firmly screw in the screw 2 aga...

Страница 20: ...rking on the worktop Fig 19 Lower the appliance into the worktop Make sure that the engaging lugs on the appliance lie exactly on the clamping springs Press the appliance firmly into the worktop The e...

Страница 21: ...Operating and assembly instructions VG 231 AU Built in gas hob wok...

Отзывы: