13
6.2 Electrical connection
Rated power consumption: 3.0 kW
Note:
if there is a need for an intermediate cupboard wall
under the hob, cut out the recess so that the trough
of the hob does not lie on the cupboard side wall
and so that a distance of
20 mm (
13
/
16
”)
from the
intermediate cupboard wall is guaranteed.
Please note that a distance of
10 mm (
13
/
32
”)
from
the base cabinet must be observed for safety
reasons. (see figure)
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
Plug must be rated not less than type 6-20 P
(2-pole 3-wire grounding).
Only a qualified electrician should install this
appliance.
The mains connecting cable must at least
correspond to the type SJTO 3x16 AWG 105°C.
You are advised to install a socket outlet earthed in
accordance with regulations approximately 70 cm
(27
1
/
2
”) above the floor behind the appliance. This
must still be accessible after installation.
The mains connecting cable must only be
purchased through and connected by an
authorised specialist.
The appliance must be properly grounded. Pay
attention to the information on the rating plate
on the unit.
Note:
when installing a shelf, observe a distance of at
least
20 mm (
13
/
16
”)
from the bottom edge of the
housing trough to the shelf or the next combustible
item of furnishing.
VC 230-612
FD xxx
xxxxxxxxx
AC 208/220-240 V
60 Hz
2500/3000 W
13 A