1. Do not allow the flame to extend beyond the

edge of the cooking utensil. This instruction is
based on safety considerations.

2.  Do not forget that the unit becomes hot when in

use. Common sense is important. Just because
the flame is out, it does not mean parts still
cannot be hot.

3.  This appliance shall not be used for space

heating. This instruction is based on safety
considerations.

4.  Be sure to disconnect the electrical supply

before disassembly of the appliance.

5.  Keep the appliance area clear and free from

combustible materials, gasoline and other
flammable vapors and liquids.

6.  Do not obstruct the flow of combustion and

ventilation air.

7.  Cabinets installed above the gas cooktop must

have a minimum distance of 600 mm (24 ´ ´ ).

8.  The gas pressure regulator supplied with the

appliance must be installed in line with the gas
pipe.

9.  The appliance and its individual shutoff valve

must be disconnected from the gas supply
piping system during any pressure testing of the
system at test pressures in excess of 3.5 kPa 
(1/2 psig). The appliance must be isolated from
the gas supply piping system by closing its
individual manual shutoff valve during any
pressure testing of the gas supply piping system
at test pressures equal to or less than 3.5 kPa 
(1/2 psig).

10.

Important:

When using a very large pot, keep a distance of
at least 50 mm (2") to avoid damaging any parts
in counter top wood, plastic or other non-heat-
resistant materials. Never leave oil or hot fat
unattended.

Note:

To avoid jeopardising the electrical safety of

the appliance, it is forbidden to use high-pressure
or steam jet cleaning devices.

Note:

The name plate is attached to the bottom of

the unit and to the inside of the housing.

Only for Installation in USA:

This installation must conform with local codes or, in
absence of local codes, with the National Fuel Gas
Code, ANSI Z 223.1 Current Issue. 

The installer must leave these instructions with the
appliance, and the consumer should keep them for
future reference. If an external electrical source is
utilized, the appliance must be electrically
grounded in accordance with local codes, with the
National Electrical Code ANSI/NFPA 70 Current
Issue.

For Massachusetts Installations:

1.  Installation must be performed by a qualified or

licensed contractor, plumber or gas fitter
qualified or licensed by the state, province or
region where this appliance is being installed.

2.  Shut-off valve must be a “T" handle gas cock.
3.  Flexible gas connector must not be longer than

36 inches.

Only for Installation in Canada:

In Canada, installation must be in accordance with
the CAN 1-B149.1 and .2 – Installation Codes for
Gas Burning Appliances and/or local codes. The
installer must leave these Instructions with the
appliance and the Consumer should retain them for
future reference. 

This appliance when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the current CSA
Standard C 22.1-Canadian Electrical Code, Part I. 

For mobile Housing and Recreational Vehicle
installation must conform  with the following:

CAN/CSA Z240 MH
CAN/CSA Z240 RV

Installation Requirement For Gas Burning
Appliances And Equipment In Mobile Homes CSA
Standard C 22:1 - Canadian Electrical Code Part 1
and /or local Codes.

Warnings

3

Содержание KG 260 CA

Страница 1: ...Operating and assembly instructions KG 260 CA Gas cooker ...

Страница 2: ... 2 2 Special accessories Page 7 2 3 Operating principle Page 8 3 Operation Page 9 4 Cleaning and care Page 10 5 Maintenance Page 11 5 1 General Page 11 5 2 Remedying slight malfunctions yourself Page 11 6 Technical data Settings table Page 12 7 Assembly instructions Page 13 18 7 1 Important notes Page 13 7 2 Electrical connection gas connection Page 14 15 7 3 Nozzle replacement Page 16 17 7 4 Inst...

Страница 3: ... vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified insta...

Страница 4: ...liance it is forbidden to use high pressure or steam jet cleaning devices Note The name plate is attached to the bottom of the unit and to the inside of the housing Only for Installation in USA This installation must conform with local codes or in absence of local codes with the National Fuel Gas Code ANSI Z 223 1 Current Issue The installer must leave these instructions with the appliance and the...

Страница 5: ... and assembly instructions conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance You will find notes on page 5 that you ought to observe before operating the appliance for the first time The chapters entitled Structure and operating principle and Operation tell you all the things your cooker is capable o...

Страница 6: ...during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse Close the gas supply Repairs must be carried out by authorised specia lists thus ensuring electrical safety No warranty claims can be lodged for any damage resulting from failure to observe these instructions Observe caution with oils and fats They may overheat and burn easily Foodstuffs that are ...

Страница 7: ...sk of burns when working next to naked flames you also save gas and reduce pollution Whenever the gas hob is fitted under a vapour extractor hood always cover the rings with pots or pans Otherwise parts of the vapour extractor hood may become damaged by the extreme heat development or grease residues in the filter may ignite Ensure an adequate supply of air when using a vapour extractor operating ...

Страница 8: ...right cooking position 7 Control knob for the front right cooking position 8 Burner head cover 9 Burner head 10 Spark plug for automatic ignition 11 Thermal sensor to safeguard the flame You can order the following special accessories VV 200 000 Connecting strip VD 201 010 Appliance cover If an appliance cover is fitted the pot support must be removed when closing 7 2 Structure and operating princ...

Страница 9: ...4 kW referred to Hs gross calorific value 28 600 BTU 8 4 kW referred to Hi calorific value The specified rated load is defined by installation of the fixed nozzles The gas hob is converted to a different gas type by nozzle replacement full and low burning nozzles see nozzle table on page 12 The symbols on the control panel mean 0 Off High setting Low setting The flame is infinitely variable betwee...

Страница 10: ... seconds turn the control knob further to the left to the low position and then back to the high position after ignition It is often faster to ignite in the low position because the various gases have a differing ignition response After igniting keep the control knob pressed for around 5 8 seconds more because the heat sensor that opens the gas channel has to warm up first Repeat the operation if ...

Страница 11: ...a moist cloth Soak burnt in remainders in a little water and detergent This loosens even the most stubborn of soiling Do not use any abrasive agents and abrasive sponges As the result of heat development slight dis coloration can appear on the stainless steel surface Do not attempt to scrape away such discoloration This damages the surface Distribute stainless steel care agents uniformly and thinl...

Страница 12: ...thorised technicians in order to guarantee the safety of the appliance Unauthorised tampering with the appliance will invalidate any warranty claims Only ever use original spare parts 11 5 Maintenance Fault Remedy The burner does not ignite after several attempts Check whether the burner is correctly assembled the gas shut off facility is open the burner is clean and dry the domestic fuse has trip...

Страница 13: ...hnical data gas Technical data electrical Rated consumption 0 8 W Voltage AC 120 V Frequency 60 Hz Technical modifications reserved 6 Technical data Settings table Countries US US CA CA Gas family Natural gas Propane gas Gas type A E Pressure 6 W C 1 5 kPa 10 W C 2 5 kPa A burner full burning 0 94 0 74 A burner low burning 0 49 0 36 B burner full burning 1 28 0 87 B burner low burning 0 58 0 42 Po...

Страница 14: ...s hob is not intended for connection to an exhaust gas system pay attention to the applicable installation conditions Note on ventilation To ensure good combustion the room in which this appliance is installed must have a minimum volume of 20 m3 and a door that opens out to outdoors or a window that can be opened The appliance may be installed in kitchen combinations made of wood or similar combus...

Страница 15: ...estab lishing connections make sure that the connecting lead cannot come into contact with hot parts of the gas hob or other hot parts Warning this appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a pro perly grounded receptacle Do not cut or remove the grounding prong from this plug The mains connecting cable must...

Страница 16: ...its into the threaded nut on the hob The longer tapered U S A thread is for the incoming gas supply Vent the gas line check for leaks The gas pressure regulator is supplied with the unit and comes set for natural gas To convert regulator to LP propane gas Make Essex Model SX 229 NA 602 1 2 PSIG 1 Remove the aluminum cap from the top of the regulator 2 Turn the cap over It will have LP 10 stamped i...

Страница 17: ... in fully at the works and so the lowest quantity is set Replacing the low setting nozzle 1 Proceed as follows Disconnect the appliance from the power supply Remove the cover from the underside of the appliance under the gas valves The low setting nozzle 1 is located in the gas valve and is screwed in from below see Fig 10 Unscrew the nozzle and insert the new nozzle as specified in the low settin...

Страница 18: ...k the new adhesive label included with the nozzle set over the old adhesive label on the gas connection thus documenting the changeover to a different gas type Checking functions The flames are adjusted correctly if no yellow tips are visible and if they do not go out when switching over swiftly from the high to the low setting Adjusting the primary air The primary air setting for different gases ...

Страница 19: ...e into the worktop Make sure that the engaging lugs on the appliance lie exactly on the clamping springs Press the appliance firmly into the worktop The engaging lugs on the appliance snap into the clamping springs Fig 14 Note When installing the appliance in granite or marble worktops have the holes produced by a specialist or stick on the securing rails with a temperature resistant 2 component a...

Страница 20: ...51 McFADDEN AVENUE HUNTINGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau usa com GAGGENAU HAUSGERÄTE GMBH CARL WERY STR 34 81739 MÜNCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 EN ...

Отзывы: