Fault
Cause and troubleshooting
Appliance door opens
too wide at the end of
the programme.
▶
Use size 4X30 bolts to adjust the door gap.
The bolts are included in the scope of supply.
If you use bolts that are too long, this can deactiv-
ate the function of automatic door opening.
E:20-60 lights up al-
ternately.
Appliance has detected calcified heating element.
1.
Descale the appliance.
2.
Operate the appliance with the water softening sys-
tem →
.
1
E:21-30 will light up
alternately.
Intake opening of Zeolith container is covered by
items of tableware.
▶
Re-arrange the tableware in the appliance so the In-
take opening of the Zeolith container →
is
no longer obstructed.
E:30-00 will light up
alternately.
Water protection system is activated.
1.
Turn off the water tap.
2.
Call Customer Service →
E:31-00 will light up
alternately.
Water protection system is activated.
1.
Turn off the water tap.
2.
Call Customer Service →
E:32-00 will light up
alternately or indicator
for water supply lights
up.
Supply hose is kinked.
▶
Install the supply hose without kinks.
Water tap is turned off.
▶
Turn on the water tap.
Water tap is jammed or furred up.
▶
Turn on the water tap.
The flow rate must be at least 10 l/min when the
water supply is open.
The filters in the water connection of the supply or
AquaStop hose are blocked.
1.
Switch off the appliance.
2.
Pull out the mains plug.
3.
Turn off the water tap.
4.
Unscrew the water connection.
1
Depending on the appliance specifications