Troubleshooting
en
45
18 Troubleshooting
You can rectify minor faults on your appliance yourself. Read the troubleshoot-
ing information before contacting after-sales service. This will avoid unneces-
sary costs.
WARNING
Risk of electric shock!
Incorrect repairs are dangerous.
▶
Repairs to the appliance should only be carried out by trained specialist
staff.
▶
Only use genuine spare parts when repairing the appliance.
▶
If the power cord of this appliance is damaged, it must be replaced with a
special connection cable, which is available from the manufacturer or his
Customer Service.
Fault
Cause and troubleshooting
E:20-60 lights up al-
ternately.
Appliance has detected calcified heating element.
1.
Descale the appliance.
2.
Operate the appliance with the water softening sys-
tem →
.
1
E:21-30 will light up
alternately.
Intake opening of Zeolith container is covered by
items of tableware.
▶
Re-arrange the tableware in the appliance so the In-
take opening of the Zeolith container →
is
no longer obstructed.
E:30-00 will light up
alternately.
Water protection system is activated.
1.
Turn off the water tap.
2.
Call Customer Service →
E:31-00 will light up
alternately.
Water protection system is activated.
1.
Turn off the water tap.
2.
Call Customer Service →
E:32-00 will light up
alternately or indicator
for water supply lights
up.
Supply hose is kinked.
▶
Install the supply hose without kinks.
Water tap is turned off.
▶
Turn on the water tap.
Water tap is jammed or furred up.
▶
Turn on the water tap.
The flow rate must be at least 10 l/min when the
water supply is open.
1
Depending on the appliance specifications