Circulating air mode

The activated charcoal filter eliminates kitchen

smells in the circulating air mode. In normal use 
(1 to 2 hours daily), the activated charcoal filter
must be replaced approximately once a year.

If no activated charcoal filter is installed, kitchen
smells will not be eliminated. 

Replacing the activated charcoal filter

remove the stainless steel grease filters. Push in the

clips on the side of the activated charcoal filter and
remove the activated charcoal filter downwardly.
Push the clips to the side and remove the activated
charcoal filter towards the front.

Insert the activated charcoal filter at an angle
(Note: be careful not to damage the light connector
on the left side). Then push the filter upwards, until
the clips on the side lock into place. Re-insert the
stainless steel grease filters. 

Activated charcoal filters (KF 001-010) are available
through your specialist dealer. Only use original
filters.

Activated charcoal filters do not contain any 
dangerous substances. They can be disposed of
through the household refuse collection.1

Cleaning the extractor hood

Clean the exterior of your extractor hood with a soft

cloth and mild detergent solution. Do not use any
strong, caustic or abrasive cleaning agents. Do not
use any abrasive sponges or brushes either.

Clean the stainless-steel extractor hood
(AW 540/AW 542) with stainless steel cleaner.

Cleaning the glass plates

Apply commercially available window cleaning

agent with a soft, moist cloth. To facilitate cleaning,
you can detach the glass plates as follows: 

Detach the grease filters. In the extractor hood, you
will find three openings on the upper side through
which you can lift the glass plates singly with a
blunt object (e.g. handle of a wooden spoon) to
detach them with greater ease.
If they are extremely soiled, the glass plates can be
cleaned in a dishwasher at a maximum temperature
of 55 °C.

Note: 

when putting the glass plates back in place,

make sure that you do not scratch the chimney. 
Replace the glass plates with the printed side 
facing down. Position the glass plates at the
chimney side first.  

Cleaning the aluminium panel

Clean the control panel with a sponge and mild

detergent solution only. Dry with a soft, dry cloth. Do
not use any strong or caustic cleaning agents or
brushes and abrasive cleaner to clean it. Do not use
strongly alkaline cleaning agents (such as oven
spray) because these are aggressive to the 
aluminium surface. Do not use any abrasive 
sponges either.

10

Fig. 15

Содержание AW 543-120

Страница 1: ...Operating and Assembly Instructions AW 540 190 120 AW 541 190 120 AW 542 120 AW 543 120 Extractor Hood...

Страница 2: ......

Страница 3: ...Page 3 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly...

Страница 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Страница 5: ...nce Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operatio...

Страница 6: ...there are accessories in the packaging Keep packaging elements e g plastic foil styrofoam parts out of the reach of children Thoroughly clean the appliance before using it for the first time see chap...

Страница 7: ...4 m LK 011 022 for ceiling heights of 2 64 3 02 m Installation accessories for circulating air mode Stainless steel design ventilation duct LK 010 112 for ceiling heights of 2 36 2 64 m LK 010 122 for...

Страница 8: ...d on or off regardless of whether the wall extractor is in operation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the ligh...

Страница 9: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Страница 10: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Страница 11: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Страница 12: ...soft cloth and mild detergent solution Do not use any strong caustic or abrasive cleaning agents Do not use any abrasive sponges or brushes either Clean the stainless steel extractor hood AW 540 AW 5...

Страница 13: ...tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use...

Страница 14: ...bottom edge of the wall hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the wall hood is 700 mm for gas appliances The hood ca...

Страница 15: ...The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Sta...

Страница 16: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction...

Страница 17: ...ix the two hooks d with the countersunk screws c Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the o...

Страница 18: ...he fastening holes on the side are at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secure it with 2 screws on the ceiling holder Fig...

Страница 19: ...lish the electrical connection Stainless steel chimney only LK 010 112 122 pull the protective film off the chimney s trims Note avoid damaging the sensitive metal surfaces Fit the top chimney duct un...

Страница 20: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 D 81739 M NCHEN Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...

Отзывы: