When pressed, all function selection keys are
backlit in green, except 

0

(“Motor off”).

Ventilation

Three fan speeds and one intensive speed are
available. You set the fan speed required for each
respective cooking process by pressing the
function selector keys 

1, 2, 3

or 

Int

.

Intensive Mode

The 

Int

key for the intensive level should be pressed

when browning and frying in an open pan. If you
have switched on the ventilator by selecting the
intensive level, it will be switched off again
automatically after 5 minutes.

If you press the 

Int

key while the ventilator is

running at fan level 

1, 2

or 

3

, the electronic control

will switch back automatically to the previously
selected fan level after 5 minutes.

If you would like to end the intensive level before
the 5 minutes have elapsed, press the 

0

key

(“Motor off”) or select a different level. It is
possible to switch off the fan at any time by
pressing the 

0

key (“Motor off”).

Light

The lighting can be switched on or off, regardless
of whether the backsplash ventilation is in
operation, by pressing the 

key.

Operation

Содержание AT 400-730

Страница 1: ...Backsplash Ventilation AT 400 700 730 Gaggenau Use and Care Manual...

Страница 2: ......

Страница 3: ...ories 8 Special Accessories 8 Accessories for Installation 8 Operating Principle 9 Operation 10 Ventilation 10 Intensive Mode 10 Light 10 Special Functions 11 Setting the Intensive Mode Duration 11 De...

Страница 4: ...RNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREF...

Страница 5: ...lash ventilation the AA 409 200 230 glass cover special accessory to be ordered separately must be placed on top of the backsplash CAUTION The housing of the backsplash ventilation and the lamp cover...

Страница 6: ...ed The frying basket holder cannot be used when operating the deep fryer VF 411 in front of the backsplash ventilation If the appliance does not function correctly check the household fuses first If t...

Страница 7: ...io 400 series appliances Features of your New Appliance Control Panel cover light air inlet control panel grease filter saturation display light delay shut off intensive mode ventilation level 3 venti...

Страница 8: ...llation AA 409 400 Furniture support 33 7 8 86 cm for AT 400 700 AA 409 430 Furniture support 45 11 16 116 cm for AT 400 730 Recommended as bearer for the countertop instead of a cabinet frame or to s...

Страница 9: ...extracted air The grease is collected in the trays The grease fine filter absorbs any remaining grease particles The activated carbon filter in the fan housing traps odors the exhaust outlet for the c...

Страница 10: ...cting the intensive level it will be switched off again automatically after 5 minutes If you press the Int key while the ventilator is running at fan level 1 2 or 3 the electronic control will switch...

Страница 11: ...shutoff time for all levels is ten minutes After these ten minutes the fan switches off but the lighting stays on Interval Ventilation Interval ventilation is a special feature of this appliance which...

Страница 12: ...re agent with a soft cloth Do not use aggressive abrasive or caustic cleaning agents Do not use cleaning agents that contain sand or chloride Do not use scouring pads or brushes Use glass cleaner and...

Страница 13: ...to the front 3 Remove the centrifugal grease filters one by one from right to left 4 Remove the grease collecting trays from right to left and empty You can clean the centrifugal grease filters and t...

Страница 14: ...r lid by pulling the bottom edge 3 Remove activated carbon filter Insert new activated carbon filter The filter mat must lie flat 4 Refit the ventilator lid Activated carbon filters do not contain any...

Страница 15: ...3 Lift off cover 4 First turn florescent lamp in the socket then lift off fluorescent lamp 5 Only replace defective fluorescent lamp by lamp of the same type 6 Insert the new fluorescent lamp into the...

Страница 16: ...Gaggenau 780 Dedham Street Canton MA 02021 Telephone 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany www gaggenau com 9000176721 EB 8702 enUS...

Отзывы: