background image

Extractor hood
AI 280120
AI 281120

Gaggenau Operating and installation instruction

Содержание AI280120

Страница 1: ...Extractor hood AI 280120 AI 281120 Gaggenau Operating and installation instruction ...

Страница 2: ...2 Fig 1 GAS Abb 1 ELECTRIC ...

Страница 3: ...cedure 8 Intensive setting 9 Special functions 9 Filters and maintenance 10 Grease filters 10 Saturation indicator F 10 Activated carbon filter 11 Cleaning and care 12 Replacing the light bulbsn 13 Installation Instructions Important information 15 Prior to installation 16 Exhaust air mode 16 Circulating air mode 17 Preparing the wall 18 Electrical connection 19 Installation 20 Table of Contents ...

Страница 4: ... measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into considerat...

Страница 5: ...tracted particularly well at the front of the cooking field The Coanda effect may allow you to operate the extractor hood at a lower quieter level than you were previously accustomed to The Coanda air flow exits the top of the extractor hood s front panel Do not place any objects on the extractor hood these may disrupt the Coanda effect 5 ...

Страница 6: ...nic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU If an F appears in the display See Filters and maintenance Section If is not possible to operate the extractor hood Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box Wait for approx 1...

Страница 7: ...r or his customer service or a similarly qualified person in order to prevent serious injury to the user The appliance may be connected to the mains by a qualified technician only Dispose of packaging materials properly see Installation instructions Never allow children to play with the appliance Do not let adults or children operate the appliance unsupervised if they are mentally or physically un...

Страница 8: ...Light Fan follow on Intensive setting The most effective method of removing vapours produced during cooking is to Switch the ventilator ON as soon as you begin cooking Switch the ventilator OFF a few minutes after you have finished cooking Fam settings ...

Страница 9: ...ltaneously pressing the Int key and the 1 2 or 3 key and you can store this setting When delivered the appliance is set to five minutes i e the combination of the Int key and the key 2 Fan follow on Delayed shut off is possible at any level First press the required key 1 2 3 or Int and then press the key The delayed shut off time for all levels is ten minu tes After these ten minutes the ventilati...

Страница 10: ... has not started to flash Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dishwasher It is however possible that they will become slightly discoloured The filter must be placed loosely and NOT wedged in the dishwasher Important Metal filters that are saturated with grease should not be wash...

Страница 11: ...emoving and inserting the metal mesh grease filters 2 Insert the activated carbon filter 3 Insert the metal grease filters see Removing and inserting the metal grease filters Replacing the activated carbon filter During normal operation 1 to 2 hours per day the activated carbon filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see opt...

Страница 12: ... prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency 몇 Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cleaner to clean the operating buttons Stainless steel surfaces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polish...

Страница 13: ...l a risk of being burnt 2 Remove the metal mesh filters see Removing and inserting the metal mesh grease filters 3 Loosen the screws for the mounting rails 4 Carefully remove the glass panes 5 Remove the sockets for the fluorescent light bulbs 6 Replace the fluorescent light bulbs with new ones available commercially 36 W 840 Cool White socket 2 G 11 몇 Risk of breakage Replacing the light bulbs ...

Страница 14: ... 9 Tighten the screws for the mounting rails 10 Insert the metal grease filters see Removing and inserting the metal grease filters 11 Restore the power by inserting the mains plug or switching on the fuse Note If the light does not function check that the bulbs have been inserted correctly ...

Страница 15: ...1 The extractor hood must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are observed The smaller the gap between the extractor hood and hotplates the greater the likelihood that droplets will form on the underside of the extractor hood Additional information concerning gas coo...

Страница 16: ...ntinuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and ...

Страница 17: ...pipework Round pipes We recommend Internal diameter 150 mm Flat ducts must have an internal cross section that equates to that of round pipes There should be no sharp bends l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Connecting a l 150 mm exhaust air pipe Mount the pipe directly onto the ai...

Страница 18: ...e to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be con nected to an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly behind the chimney panelling The earthed socket should be connected via its own circuit If the earthed ...

Страница 19: ...iance after removal of the filter frame 몇 Before undertaking any repairs always disconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m This extractor hood corresponds to EC regulations concerning RF interference suppression 19 ...

Страница 20: ...Ø 8 mm for the wall plugs Push the plugs flush with the ceiling 3 Turn two screws to a 10 mm gap Both screws are placed in a position in which at a later stage of the installation the key holes of the supporting frame are found namely back left and front right from the control panel of the hood 4 Adjust the support frame to the desired height and secure with 8 screws 12 screws for the longer venti...

Страница 21: ...and attach it with all 4 screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Cut the flexible air pipe to the required length and fix it to the extractor hood 6 Remove the cover plate from the rear of the support frame ...

Страница 22: ...p chimney duct unit which has no magnetic strips with 2 screws on the top of the support frame 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the first chimney duct easily Adjust leave no gap and fix with 2 screws to the top of the support frame 15 Place the bottom chimney duct unit which has no magnetic strips on the extractor hood The...

Страница 23: ...KF001 010 23 ...

Страница 24: ...Gaggenau Hausgeräte GmbH Carl Wery Straße 34 D 81739 München www gaggenau com 9000260298 EB 8710 en ...

Отзывы: