background image

8

The 

Int

key for the intensive level should be 

pressed when browning and frying in an open pan 
(see Fig. 6).
If you have switched on the hood by selecting the
intensive level, it will be switched off again 
automatically after 5 minutes.

If you press the 

Int

key while the hood is running at

fan level 

1, 2

or 

3

, the electronic control will switch

back automatically to the previously selected fan
level after 5 minutes (see Fig. 7).

If you would like to end the intensive level before
the five minutes have elapsed, press the 

0

key

(“Motor off”) or select a different level (see Fig. 8).
It is possible to switch off the extraction function at
any time by pressing the 

0

key (motor “off”).

Fig. 6

Fig. 8

Fig. 7

Содержание AI200702

Страница 1: ...Operating and Assembly Instructions AI 200 Extractor Hood...

Страница 2: ......

Страница 3: ...For your safety Page 4 1 2 Operating for the first time Page 5 1 3 About use Page 5 2 Features Page 6 3 Operation Page 7 9 4 Cleaning and care Page 10 11 5 Maintenance Page 12 6 Assembly instructions...

Страница 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Страница 5: ...Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Alway...

Страница 6: ...using more than 3 gas operated rings at the same time please operate the extractor hood at level 2 or higher This prevents a build up of heat in the appliance For safety reasons do not place any heavy...

Страница 7: ...f children Thoroughly clean the appliance before using it for the first time see chapter Cleaning and care Before operating the appliance for the first time check that the mains connection is in prope...

Страница 8: ...of 7 4 7 11 AD 011 026 for ceiling heights of 7 11 9 AD 011 036 for ceiling heights of 9 9 9 Installation accessories for circulating air mode Stainless steel design ventilation duct AD 010 126 for ce...

Страница 9: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Страница 10: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Страница 11: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Страница 12: ...out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 130 F 55 C where it should be supported...

Страница 13: ...ilter must be replaced approximately once a year If no activated charcoal filter is installed kitchen smells will not be eliminated The activated charcoal filter KF 001 010 is available through your s...

Страница 14: ...safety of the appliance Unauthorised tampering with the appliance will invalidate any warranty claims Only ever use original spare parts Lamp replacement Caution disconnect the power supply before re...

Страница 15: ...ropriate for the appli cation and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit f NEVER place a switch where it can be reached from a tub or shower WARNING To reduce...

Страница 16: ...chimney that is not in operation During the course of planning a chimney sweep must be consulted if a room air dependent hearth is operated in the same room as the one in which a hood is operated in...

Страница 17: ...air line The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air...

Страница 18: ...20 Note this hood has been approved for installations as low as 30 and as high as 36 above the cooktop Circulating air mode only there are four brackets which fix the circulating air switch module to...

Страница 19: ...screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Fig 22 and 23 Cut the flexible air pipe to the required length and fix it to the...

Страница 20: ...t which has no magnetic strips with 2 screws on the top of the support frame Fig 26 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the fir...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...780 Dedham Street Canton MA 02021 USA Telephone 877 4GAGGENAU Fax 714 901 5360 www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany www gaggenau com 9000232642 EB 8...

Отзывы: