13
6.1 Technical data
Weight: 41 kg without ventilation duct
Dimensions: 47
3
/
16
´ ´ x 22 ´ ´ / 1198 x 560 mm
Electrical connection
Pay attention to the rating plate data.
The appliance must only be connected by an
authorised specialist
. The specialist is respon-
sible for perfect functioning of the appliance at its
installation location. He must explain the operating
principle of the appliance to the user with
reference to the operating instructions. He must
explain to the user how the appliance can be
isolated from the mains whenever required.
Connection possibilities
It must be possible to isolate all poles of the
appliance from the mains by way of the domestic
fuse, or by means of accessible isolating device
with a contact gap of at least 3 mm.
If the appliance is to be operated
only with the
window open
(to ensure adequate incoming air),
you can use the
window switch
.
A switch (normally open) is fitted on the window.
On the appliance, this switch is connected to the
window switch terminal on the main electronics.
The appliance can now only be operated when the
window is open.
Important: the window switch must only be
connected by an
authorised specialist.
Note: the light function works without restriction.
6. Assembly instructions