background image

Rev 2/14 

 

S/N: 2094 AND ABOVE  

PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS. 

SAFETY WARNINGS 

PLEASE READ THIS MANUAL BEFORE  

SERVICING OR USING THIS TOOL.  

 

WARNINGS: 

 

MUST BE UNDERSTOOD TO AVOID 

SEVERE PERSONAL INJURY 

CAUTIONS: 

 

SHOW CONDITIONS THAT WILL 

DAMAGE EQUIPMENT OR STRUCTURE 

WARNING

 

Do not pull fastener unless it is placed

 

in an 

assembly, pin will eject forcibly

 

when pintail breaks 

off. Severe

 

personal injury may result. 

WARNING

 

When operating, repairing or overhauling tool, wear 

approved eye protection. Do not look in front of 

nose assembly or rear of tool when installing 

fastener.

 

WARNING

 

Always disconnect tool from power

 

before 

performing any maintenance

 

to any tool or nose 

assembly.

 

Ensure

 

that all connections are proper 

and

 

there are no visible leaks from tool

 

or hoses 

before connecting to power. 

CAUTION

 

Ensure that nose assembly and tip

 

are properly 

matched for the

 

fastener being installed. 

CAUTION

 

Keep Nose Assemblies clean and free

 

of chips and 

debris. 

WARNING

 

Be sure there is adequate clearance for

 

tool and 

operator's hands before

 

proceeding. Keep fingers 

clear of any moving parts. Keep fingers clear from

 

fasteners and installed materials.

 

Severe personal 

injury may result.

 

WARNING

 

Do not use beyond the design intent. 

WARNING

 

Tool must be maintained in a safe working 

condition at all times and examined on a regular 

daily basis for damage or wear.  Any repair should 

be done by qualified personnel trained on Gage Bilt 

procedures. 

WARNING

 

Where prolonged use is foreseen, it is 

recommended a tool balancer be used. Check 

suspension device to ensure that it is secure. 

WARNING

 

Do no use tool in explosive atmosphere. 

WARNING

 

Tool is not to be used as a hammer. 

WARNING

 

Risk of crushing exists if nose assembly is not  

attached. 

WARNING

 

It is recommended tool be operated 50 out of every 

60 minutes, where prolonged use is expected. 

WARNING 

Shock: 

 

It is recommended operator wear a suitable glove 

during operation where prolonged use is expected. 

WARNING 

Air pressure not to exceed 100 psi. (6.9 bar) ,  

except where noted. 

WARNING

 

It is required to use hearing protection. A test was 

carried out in a simulated work environment where 

the background level was 73.2 dB (A). In this 

condition the max level was 81.5 dB (A). Therefore, 

it is required where prolonged use, hearing 

protection be used.

 

Содержание GB51

Страница 1: ...nc 44766 Centre Court 586 226 1500 Clinton Twp MI 48038 586 226 1505 Fax e mail solutions gagebilt com www gagebilt com GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E MAIL US FOR A DISTRIBUTOR NEAR YOU S N 2094 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS ...

Страница 2: ...cription Operation and Maintenance 5 Parts Lists 6 Nose Assembly Selection Chart 7 EU Conformity and Warranty 8 SPECIFICATIONS Hand Held Weight 2 50 lbs 1 13 kg Air pressure req d 90 psi 6 2 bar 100 psi 6 9 bar Air consumption 29 SCF cycle 8 21 L cycle Setting stroke 740 18 8mm Noise level 81 5 dB A Rated pull load 1000 lbs 4 45kN Vibration Tested No hazards found 5 31 2 64 Ø 7 17 ...

Страница 3: ...ands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed materials Severe personal injury may result WARNING Do not use beyond the design intent WARNING Tool must be maintained in a safe working condition at all times and examined on a regular daily basis for damage or wear Any repair should be done by qualified personnel trained on Gage Bilt pr...

Страница 4: ...nto bottom of handle 510322 Only use an air supply set at 90 psi 6 21 bar 100 psi 6 89 bar equipped with a filter regulator to prevent wear 2 Connect air hose with 90 psi 6 21 bar to tool 3 8 minimum diameter air line is mandatory 90 psi 6 21 bar is recommended and cycle tool a few times by depressing and releasing actuator Clean dry air is mandatory WARNING ENSURE AIR HOSE IS SECURELY CONNECTED T...

Страница 5: ...et at 90 psi 6 2 bar 100 psi 6 9 bar equipped with a filter regulator to prevent wear Proper care by operator is necessary in maintaining full productivity and reducing downtime Read all applicable tool manuals and nose assembly data sheets prior to operating tools Keep nose assemblies especially jaws clean and free of chips and debris Lube jaws and collet surfaces that jaws ride on with light mac...

Страница 6: ...Bushing 1 3 S15 Retaining Ring 8 4 400858 O Ring 6 5 400807 O Ring 3 6 510119 Front Seal 1 7 510217 Drawbolt 1 8 510101 Piston 3 9 510104 Sleeve 2 10 510102 Divider 2 11 S17 Connector Bolt 1 12 510114 Cushion 1 13 510118 Back Cap 1 14 510121 Head Assembly 1 15 400782 O Ring 1 16 510105 Seal 1 17 510125 Seat 1 18 510215 Dowel Screw 2 19 510322 Handle 1 20 510107 Actuator 1 21 400772 O Ring 1 22 A 8...

Страница 7: ...ES 715 40OS 5 32 3 5CES 715E 43 5CES 715 54RA 5CES 715 40OS 3 16 3 6CES 715E 43 6CES 715 54RA 6CES 715 40OS 3 32 3C 715B 43 3C 715 54RA 3C 715 40OS 1 8 4C 715B 43 4C 715 54RA 4C 715 40OS 5 32 5C 715B 43 5C 715 54RA 5C 715 40OS 3 16 6C 715B 43 6C 715 54RA 6C 715 40OS 1 8 3C 715B 43 3C 715 54RA 3C 715 40OS 5 32 4C 715B 43 4C 715 54RA 4C 715 40OS 3 16 5C 715B 43 5C 715 54RA 5C 715 40OS 1 RIGHT ANGLE ...

Страница 8: ...or consequential damages or for damages incurred by the buyer or subsequent user in repairing or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Seller is not notified in writing of any rejections or defects within 6 months after the receipt of the material by the customer THIS WARRANTY IS MA...

Отзывы: