background image

 

10

 

 

8/16 REV 4/23

 

 

GB206

-

500/ GB206

-

500A INSTALLATION TOOL

 

DAILY MAINTENANCE

 

 

WARNING

Tool must be maintained in a safe working condition at all times and examined on a daily basis for damage or 

 

wear. Any repair must be done by qualified personnel trained on Gage Bilt procedures.

 

 

WARNING

Excessive contact with hydraulic oil and lubricants should be avoided. 

 

 

WARNING:

 

Maintenance personnel 

MUST

 

read and understand all warnings and cautions.

 

 

WARNING

:

 

Disconnect tool from its power source before performing maintenance, cleaning or when replacing worn or 

 

 damaged components. Severe personal injury may occur if power source is not disconnected. 

 

 

WARNING: 

Read material Safety Data Sheet documents for all applicable materials

 

Note: 

 

• 

Dispose of hydraulic oil in accordance with manufacture safety datasheet.

 

• 

All tool materials are recyclable except rubber o

rings, seals and wipers.

 

 

The performance of any tool depends upon good maintenance practices. Following these minimal requirements daily will extend the 

life of your tool.

 

 

  * Only use a clean dry air supply set at 90 

-

 100 p.s.i. (6.2 

-

 6.9 bar) Max. equipped with a filter

-

regulator to prevent wear.

 

 

 

 * Check tool and nose assembly for damage. (Replace/Repair if necessary). See Overhaul pg. 12 for tool repair.

 

 

  * Inspect all hoses and couplings for wear, damage and leaks. Replace/Repair if necessary. (

See hydraulic thread preparation below)

.

 

 

  * Verify that hydraulic hose fittings and couplings, air and electrical connections are secure. Tighten, Replace or Repair if necessary

 

     (

See hydraulic thread preparation below)

.

 

 

  * Cycle the tool several times to assure there are no leaks during use.

 

 

  *

 

 Only use a hydraulic power source equipped with relief valves and pressures set within specific limits (See required max pressure 

 

 for pull and return).

 

 

  * Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor.

 

 

  * Do not use as a hammer to force fasteners into holes or otherwise abuse tool.

 

 

  * Proper care by operators is necessary in maintaining full productivity and reducing downtime.

 

 

 

  

* Keep nose assemblies, especially jaws, clean and free of chips and debris. Lube jaws and collet surfaces that jaws ride on with 

light machine oil on a daily basis.

 

 

* All Screwed End Caps, Base Covers, Air Fittings, Air Actuators, Screws and Nose Assemblies are to be examined at the end of 

each working shift to check that they are secure.

 

 

SEE TROUBLESHOOTING (PG. 11) AND OVERHAUL (PGS. 12) FOR FURTHER GUIDANCE.

 

CLEANING AND LUBRICATING PROCEDURE

 

Daily cleaning of nose assembly will greatly reduce downtime and increase life of components.

 

 

 

 

HYDRAULIC THREAD PREPARATION

 

IMPORTANT:

 

Be sure to use thread sealant on all hydraulic fittings, Loctite® 545 or equivalent or a non

-

hardening Teflon® thread 

compound such as Slic

-

tite®. Tighten until fitting feels snug and then continue to tighten 1/2 to 1 full turn. 

CAUTION:

 Over tightening 

can easily distort the threads. DO NOT USE TEFLON® TAPE.

 

CAUTION:

 

Teflon® tape is an excellent thread sealer, however, if it is not 

properly applied, pieces of Teflon® may enter the hydraulic system and cause a malfunction or damage. 

 

CLEANING 

 

 

Clean nose assembly daily or as often as needed.

 

 

1.

 

Dip nose assembly into mineral spirits or similar solvent 

to clean jaws and wash away metal chips and debris. 

DO NOT allow jaws to come in contact with other solvents. 

DO NOT let jaws soak. Dry jaws immediately.

 

 

2.  Disassemble nose assembly and use a sharp 

pick

” 

to 

 

     remove embedded particles from grooves of jaws.

 

Содержание GB206-500

Страница 1: ...MAIL US FOR A DISTRIBUTOR NEAR YOU 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www gagebilt com GB206 500 GB206 500 A INSTALLATION TOOL OR...

Страница 2: ...Technical Specifications 4 Description of Functions 5 Warnings 6 Principle of Operation 7 How to set up the GB206 500 GB206 500A 8 How to use the GB206 500 GB206 500A 9 Maintenance 10 Troubleshooting...

Страница 3: ...epairing or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Seller is not notified in writing...

Страница 4: ...y weigh just over 3 lbs 1 36kg and can be operated in any position They have a 500 12 7mm fastener setting stroke and a rated pull load of 5 825 lbs 25 9 kN The GB206 500 electric actuated installatio...

Страница 5: ...5 8 16 REV 4 23 GB206 500 GB206 500A INSTALLATION TOOL DESCRIPTION OF FUNCTIONS Hydraulic Hose Pull Hydraulic Hose Return Cylinder Assembly Optional Hydraulic Hose Return and Hydraulic Hose Pull Inlet...

Страница 6: ...tool weight it is recommended safety shoes be worn during operation 11 It is recommended tool be operated not more than 50 out of every 60 minutes where prolonged use is expected REPETITIVE MOTIONS H...

Страница 7: ...er The anvil is forced over the collar swaging it into locking grooves of the fastener Further force breaks the pintail off approximately flush with the collar When the piston nears the end of its str...

Страница 8: ...into piston assembly and tighten using hex key S H C S 206101 STOP 206102 WARNING Only qualified and trained operators shall install adjust or use the assembly power tool for non threaded mechanical...

Страница 9: ...this equipment WARNING The users or the user s employer must assess specific risks that could be present before each use based on their application Ensure there is adequate clearance for tool and ope...

Страница 10: ...y use a hydraulic power source equipped with relief valves and pressures set within specific limits See required max pressure for pull and return Keep hydraulic system free of dirt Avoid letting coupl...

Страница 11: ...OIL OVERHEATS a Powerunit motor rotation reversed Electrical connections reversed See powerunit instruction manual b Restrictions in either hydraulic lines hoses or couplings Check and tighten clean...

Страница 12: ...performing poorly or leaking a complete overhaul may be necessary Perform overhaul in a clean well lit area using care not to scratch or nick any smooth surface that comes in contact with an o ring Us...

Страница 13: ...stroke limiter must be ordered Sold separately 1 To re assemble or disassemble stroke limiter 206112 relief valve 206110 see overhaul instructions 1 thru 7 on pg 12 2 To decrease stroke to 375 9 5 mm...

Страница 14: ...14 8 16 REV 4 23 GB206 500 GB206 500A INSTALLATION TOOL GB206 500 GB206 500A PARTS LIST...

Страница 15: ...3 MBC04 206H 37OS 3 5 32 MBC05 206H 27OS 3 MBC05 206H 37OS 3 3 16 MBC06 206H 27OS 3 MBC06 206H 37OS 3 13 64 GS8 206H 32OS GS8 206H 42OS 17 64 GS10 206H 32OS GS10 206H 42OS NOTE THE LAST 2 DIGITS OF TH...

Страница 16: ...ion gages to certify correct swage installation Sold Separately Stroke Limiter 206112 Required with 206110 relief valve to reduce stroke to 375 9 5 mm Sold Separately Grip Gage GB105093 For NAS LOCKBO...

Страница 17: ...Powerunit is available separately or in kits including hydraulic quick disconnect couplers air connectors air lines and hydraulic hoses in various lengths GB910 12 GB910 and pt 910701 12 ft Hose Kit...

Страница 18: ...INSTALLATION TOOL Alternative Styles Sold Separately GB731OS 206 Stroke 500 12 7 mm Hand held weight 5 75 lbs 2 60 kg Pull load 4 800 21 4 kN GB745 206 500 SERIES Stroke 500 12 7 mm Hand held weight...

Страница 19: ...19 8 16 REV 4 23 GB206 500 GB206 500A INSTALLATION TOOL This page intentionally left blank...

Страница 20: ...TRADEMARK OF E I DUPONT DE NEMOURS CO LUBRIPLATE IS A REGISTERED TRADE MARK OF FISKE BROTHERS REFINING CO SLIC TITE IS A REGISTERED TRADEMARK OF LA CO INDUSTRIES INC Riveter Kits Available Sold Separa...