![Gacell CT-15000 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/gacell/ct-15000/ct-15000_user-manual_3137185006.webp)
5
(Hold Mode
button for 3
seconds to
enter)
requires a higher than normal charging
voltage (Blue LED)
12V LITHIUM
(Hold & Press)
50-400
Charging 12V lithium-ion batteries only,
including LiFePO4 (White LED)
REPAIR
(Hold & Press)
50-400
An advanced battery recovery mode for
repairing old, idle, stratified or sulfated
batteries. REPAIR Yellow LED + 12V/24
mode LEDs
13.6V SUPPLY
(When the
charger is not
connected
with battery,
Hold & Press)
–––
Converting to a DC power supply for
powering 12V DC device or as a memory
retainer when replacing a battery (Yellow
LED)
12V JUMP
CHARGE
(Press)
50-400
Delivering 15A for five (5) minutes to jump
charge your battery (RED LED)
These
“
Hold or / and Press
”
modes are advanced charging modes that
require your full attention before selecting.
Using 12V AGM+ (Hold)
This mode is designed for 12V advanced AGM batteries only. Advanced
AGM batteries are typically found in startstop micro-hybrid vehicles.
These batteries accept a higher than normal charging voltage. 12V
AGM+ charge mode is NOT suitable for traditional AGM batteries.
Consult the battery manufacturer before using this mode.
Using 12V LITHIUM (Hold & Press)
This mode is designed for 12V lithium-ion batteries only, including
LiFePO4. Some lithium-ion batteries may be unstable and unsuitable for
charging. Consult the lithium battery manufacturer before charging and
ask for recommended charging voltage and current.
Using REPAIR (Hold & Press)
This mode is for LEAD-ACID batteries only. It is an advanced battery