12
ECO INTERVAL PERIOD WITH REDUCED TEMPERATURE
It is possible to set up a reduced temperature to a daily time period. During this ECO TEMPERATURE time period the set up
temperature will be reduced by 3ºC.
Using the PC and PD settings under GENERAL SETTINGS it is possible to program the ECO TEMPERATURE time period. See
the “General Settings” section to modify them.
PC sets up the starting time of the ECO TEMPERATURE period.
PD sets up the ending time of the ECO TEMPERATURE period.
For example, if we have a set up temperature of 21.5ºC and introduce a PC time of 13:00h and a PD time of 17:00h, we will
have an ECO TEMPERATURE period from 13:00h to 17:00h with a set up temperature of 18.5ºC. For the rest of the day the
set up temperature will be 21.5ºC
Once the ECO TEMPERATURE time period has been programmed, it will be repeated every day.
If WEEKLY PROGRAMMING is activated it is possible to override the ECO TEMPERATURE time period on Saturday and/or
Sunday.
Under clock settings and only for days number 6 and 7 (Saturday and Sunday) we can programme the following options:
-
FROST PROTECTION MODE will be represented by one small vertical bar.
-
SELECTED MODE will be represented by two vertical bars. In this option we will maintain the last mode selected
(out of the five modes available) WITH ECO TEMPERATURE time period.
-
SELECTED MODE, WITHOUT ECO TEMPERATURE time period, it will be represented with two bars and a small
red dot beside.
To cancel the ECO TEMPERATURE time period set up the same hour in PC and PD settings.
In this example, Ecombi will be operating in normal
mode from Monday (day 1) to Friday WITH ECO
TEMPERATURE time period, and it will be operating in
normal mode WITHOUT ECO TEMPERATURE time
period on Saturday and Sunday.