11
GENERAL SETTINGS:
ECOMBI general operation settings can be modified.
By pressing the
key at the same time we connect the device with the mains switch located at the right side panel, we
enter to the general settings menu. This is:
P1
Starting time of reduced (off peak) rate electric period.
P2
Ending time of reduced rate electric period.
P3
Starting time of the second reduced rate electric period (if not available set up 00.00).
P4
Ending time of the second reduced rate period (if not available set up 00.00)
P5
Temperature sensor correction (values from -5ºC to +5ºC)
P6
Deferred charge ON: charge ends at the same time than reduce rate period.
OFF: charge stars at the same time than reduce rate period...
P7
Weekly programming ON/OFF.
P8
Limit factor of emitter operation mode to increase or reduce the charge
(Possible values 0.05 - 0.10 - 0.15 - 0.20 - 0.25 - 0.30 - 0.35 - 0.40)
P9
Percentage of automatic charge regulation (values: 05-10-20-25)
PA
Excess of temperature protection during the charge. Degrees higher than the set up
temperature when the charge is interrupted. (Values 1 - 2 - 3 - 4 - 5)
Advance with the keys
and
, push the
key to enter in a parameter. Use same keys to modify it.
To save the new values it is necessary to pass through all of them to the last one (PA).
DEFAULT SETTINGS:
By pushing the Clock key of the device connected to the mains. Software resets to the default settings. Four horizontal blinking
segments will appear in the screen to confirm it.
4.- MAINTENANCE
ECOMBI does not need any special maintenance.
Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.
Do not use any solvent or abrasive product for cleaning.
When the Heating season is finished, please disconnect the device by the mains switch located at the right back lateral of the
unit.
ECOMBI has been manufactured under a fully assured quality system and using environment friendly processes.
Once its useful life is finished please take the device to a clean point so that its components can be recycled in an adequate way.
5.- TROUBLESHOOTING
ECOMBI does not heat.
Please check it is connected and switched on.
Make sure the device is not covered or the lower air inlets are not obstructed. May be the LR limit
thermostat is activated; in this case it is necessary to rearm it manually.
ECOMBI does not reach set up
temperature
Make sure that adequate temperature is selected.
Make sure room heat looses fit the power of the device.
ERR 1 in display
Temperature sensor trouble, please do contact to the technical assistance.
Key board does not respond
If display shows [ - - ] display is blocked. Press at the same time “+” and “-” key during some seconds
to unblock it..