9. Turn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve OFF. If
leak is at Hose/Regulator connection: tighten connection and perform another leak test.
If bubbles continue appearing should be returned to hose’s place of purchase. If leak is
at Regulator/Cylinder Valve connection: disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several attempts, cylinder valve is defective and
should be returned to cylinder’s place of purchase.
10. Do not transport heater while it’s operating.
11. Do not move the heater after it has been turned off until the temperature has cooled down.
12. Do not paint the radiant screen, control panel or top canopy reflector.
13. Control compartment, burner and circulation air passageways of the heater must be kept
clean.
14. Frequent cleaning may be required as necessary.
15. The LP tank should be turned off when the heater is not in use.
16. Check the heater immediately if any of the following occurs:
• The heater does not reach temperature.
• The burner makes popping noise during use (a slight noise is normal when the burner is
extinguished).
• Smell of gas in conjunction with extreme yellow tipping of the burner flames.
17. The LP regulator/hose assembly must be located out of pathways where people may trip
over it or in area where the hose will not be subject to accidental damage.
18. Any guard or other protective device removed for servicing the heater must be replaced
before operating the heater.
19. Adults and children should stay away from high temperature surface to avoid burns or
clothing ignition.
20. Children should be carefully supervised when they are in the area of the heater.
21. Clothing or other flammable materials should not be hung on the heater or placed on or near
the heater.
22. To change the gas cylinder in a amply ventilated area, away from any ignition source
(candle, cigarettes, other flame producing appliances).
23. To check that the regulator seal is correctly fitted and able to fulfill its function as showed in
the picture on right.
24. To not obstruct the ventilation holes of the cylinder housing.
25. To close the gas supply at the valve of the gas cylinder or the regulator after use.
26. In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall
be shut off and the appliance shall be investigated and rectified before it is used again.
27. To check the hose at least once per month, each time the cylinder is changed or each time
before long time no use. If it shows signs of cracking, splitting or other deterioration it shall
be exchanged for new hose of the same length and of the equivalent quality.
28. Read the instructions before using this appliance. The appliance must be installed in
accordance with the instructions and local regulations.
29. For connection of hose and regulator and connection of regulator and hose, please refer to
photo showed above.
100cm
91cm