First Flight Version 1.0
Printed: 1/26/2008
Fatal Error Status Codes
Break Wire Error
The unit is configured for a breakwire launch but the break wire is not connected.
1.
Short warble.
2.
A 1 second pause, and then the sequence repeats.
Warning: If you hear this sequence, you will not be able fly your rocket until the error is
corrected. Follow these instructions to correct the problem.
To Correct the Setup, If You Want a Breakwire Flight
1.
Power your unit off.
2.
Connect your break wire.
3.
Power your unit on to continue.
To Correct the Setup, If the Breakwire Mode was Configured by Mistake
1.
Power your unit off.
2.
Attach a wire between the two Breakwire terminals (TB2 pins 3/4).
3.
Connect your flight computer to FlightView.
4.
Go into the Configuration screen.
5.
Uncheck the Breakwire Launch Detect checkbox.
6.
Disconnect from FlightView.
7.
Power-cycle your flight computer to continue.
Power-On Self-Test Failure (POST Failure)
1.
Long warble.
2.
Half second delay.
3.
1 – 7 high pitch beeps giving a failure code.
o
For 1 to 4 beeps see the Hardware Error chart.
o
For 5 beeps, there will be an additional set of lower pitched beeps. Count these beeps
and see the Initialization Error chart.
o
For 6 beeps, there will be an additional set of lower pitched beeps. Count these beeps
and see the File Creation Error chart.
o
For 7 beeps, the SD card is full.
4.
A 1 second pause, and then the sequence repeats.
Page 36