3. Fire safety

When cutting or engraving materials, the equipment uses a high density laser beam to illuminate 
the material, so that the surface of the material produces high temperature, the purpose is to vapor

-

ize the material without burning it. But most materials are inherently flammable and can ignite and 
form an open flame, which can burn down the device (even if the fuselage is made of flame-retar

-

dant material) and its surroundings. Research shown that vector cutting with lasers is most likely to 
produce flames.

          

Carefully read the warnings and advice:

    Children, minors and people without self-protection awareness are strictly prohibited from han

-

dling the product.
    When the laser device is working, do not look at the laser with naked eyes. Wear laser goggles.
    When the laser is working, ensure that the working environment is well ventilated. Other radia

-

tion, harmful gas, poisonous gas, or odor-smelling gas may be generated due to the different 
objects that the laser directly targets.
    When the laser is working, place a fire extinguisher nearby. Do not stack inflammable and explo

-

sive materials around the workbench and the device to prevent accidental fire caused by the laser.
    When the laser is working, keep a proper distance from the device and wear protective equip

-

ment, such as safety goggles and protective covers.
Do not leave the laser equipment unattended when working.

4. Electrical safety

         Carefully read the warnings and advice:

    When the device is connected to the power supply, do not remove any parts of the laser to avoid 
accidental power shock.
    When the device is connected to the power supply, do not touch the electronic area with hands or 
other tools.

Содержание G1

Страница 1: ......

Страница 2: ...Table Of Contents 01 List of product accessories standard optional 02 Key indicator description 03 Quick Installation Instructions 04 Product speci cation 05 Use safety guidelines 06 Precautions 01...

Страница 3: ...01 List of product accessories Beam E Transmission shaft F Front Frame A Left Frame B Right Frame C Rear Frame D 02...

Страница 4: ...Tray Safety shield Risers Power Adapter and Power Cord G Optional H Countersunk screws M4 8 Countersunk screws M3 8 Countersunk screws M4 25 Circlip Plier Round screws M4 10 Fixed Focus Block Safety g...

Страница 5: ...02 Keys and Indicators Instructions Laser souce Indicator light Focus lever Air nozzle adapter Smoke exhaust hole Power interface Emergency stop button USB interface Power switch Extended shaft interf...

Страница 6: ...ick Installation Instructions 3 1 Assembling GWEIKE G1 Blu ray platform Assemble the four side baf es together and align the power switch power port and USB port with the openings on the baf e A A B B...

Страница 7: ...ame and back frame as shown in the gure Install 8 M3 8 screws on the upper and lower sides of the front frame and 2 M3 8 screws on the back frame with a hex wrench and then install 6 M4 8 screws and 2...

Страница 8: ...07 Use M4 25 screws to secure the synchronous belt wheel M4 25 Screws are used to adjust the tightness of the belt Please do not tight en them too much to prevent breaking 2...

Страница 9: ...install risers Take out the four groups of risers unscrew the bottom risers remove the rubber plug on the risers install the four risers on the machine with four M4X10 screws and then install the rubb...

Страница 10: ...he conveyor belt Note that the conveyor belt needs to be covered on the idler wheel of the optical shaft Note If the optical shaft cannot pass through the belt during installation it may be because th...

Страница 11: ...ote When the coupling slides to the intersection of the optical shaft and the motor shaft do not cling to the motor leaving a little space between the motor and the coupling otherwise the rotation of...

Страница 12: ...11 Tighten the two screws on the coupling...

Страница 13: ...to install the four M4 8 screws on the left and right sides of the beam and install one M4 25 adjusting screw Note M4 25 Screws are used to adjust the tightness of the belt Please do not tighten them...

Страница 14: ...lide from top to bottom Slide the laser head down to the appro priate position and then tighten the screws on the right hand Insert the power supply cable connec tor of the laser head into the laser t...

Страница 15: ...14 Complete the connection Insert the connectors of the laser motor and limit switch cables into the cor responding interfaces of the motherboard according to the corresponding colors of the terminals...

Страница 16: ...15 Use cable ties to secure the cables...

Страница 17: ...The machine can be raised by hand twisting the plastic foot pad set The roller rotary optional can be connected to the rotating shaft terminal of the machine board card blue through the connecting wi...

Страница 18: ...belt tightness Adjust conveyor belt tightness Tips Please try to keep the tightness of the left and right baf e conveyor belts consistent to ensure proper cutting and engraving Tighten the screw cloc...

Страница 19: ...n the other side and slide the laser up and down so that the focus block is attached to the laser on the top and the cutting material on the bottom After determining the position tighten Tighten the s...

Страница 20: ...connection 3 Connect the USB cable to the computer and connect the other end of the USB to the machine 2 Settings in Lightburn 1 Open Lightburn If this is the rst time you have opened Lightburn use t...

Страница 21: ...20 2 Manually add devices 3 Select Smoothieware controller from the list and click next...

Страница 22: ...21 4 Select the USB connection mode and click next 5 Change the name of the device and set the size of the working area to the X axis length of 400mmy axis length of 330mm Click next...

Страница 23: ...he rear right if the laser does not need to be automatically reset each time it is started then the laser needs to be automatically reset and turned off Click next 7 Con rm the setting of the device a...

Страница 24: ...23 8 Select the device from the drop down menu at the lower right corner of the page to complete the setting 9 After selecting the device is completed Select Current Position from Start From...

Страница 25: ...preference and set the work area size to 400mm x axis length and 330mm y axis length then select next step 5 Select the right rear as the laser origin if you do not need the laser to automat ically r...

Страница 26: ...25 Supported le format 2 Set processing layer style line ll ll line offset ll processing priority pro cessing parameters...

Страница 27: ...26 3 Go border determine processing position start start processing...

Страница 28: ...27 Please clean the laser when the hood is dirty or the laser cannot cut through the materials 1 Disconnect the power of device and remove the laser from the machine Laser Cleaning...

Страница 29: ...ad 3 Clean the inside and outside of the protective cover with a cleaning tissue or dust free cloth moistened with alcohol and clean the laser prism with cotton swab moistened with alcohol Nozzle Air...

Страница 30: ...ms Output Voltage Input Power Working Temperature Ambient temperature Connecting Interfaces Overall Machine Size Machine Weight Package weight File Type s 120W 10w 450nm 0 08x0 06mm 0 01mm 400mm s 400...

Страница 31: ...y The laser is usually wrapped in a shell a mask to work Even if you already have a mask that blocks part of the laser light protect your eyes with the included goggles Please follow the operating pri...

Страница 32: ...naked eyes Wear laser goggles When the laser is working ensure that the working environment is well ventilated Other radia tion harmful gas poisonous gas or odor smelling gas may be generated due to...

Страница 33: ...wiring plug backwards 3 If the problem is still not solved plug the laser terminal plug and check whether the wire is damaged 3 Why can t the laser move during work after the machine is assembled Pos...

Страница 34: ...eam 1 Loosen screw 1 rst and then adjust screw 2 2 When adjusting screw 2 tighten it clockwise Loosen counterclockwise 3 After adjusting the tightness of the conveyor belt tighten the screw 1 Tighten...

Страница 35: ...s During the maintenance cycle if dirt and impurities occur it is necessary to clean the surface of the optical shaft immediately to ensure that the optical shaft is clean and apply grease Maintenance...

Страница 36: ...d service quality so it reserves the right to change any product or software program described in this manual and the content of this manual at any time without notice This manual is intended to help...

Отзывы: