OVERVIEW 

The BDA assembly enhances the coverage area of radio communications in buildings and RF 
shielded environments. 
The BDA has dual RF paths (Down-Link / Up-Link) to improve coverage in two distinct 
frequency bands.    
The unit features low noise figure and wide dynamic range. It is based on a dual duplexed 
path configuration with sharp out of band attenuation allowing improved isolation between the 
receiving and transmitting paths. 
BDA-PS8NEPS-37/37-90-AB provides up to 37 dBm composite power and has up to 92 db 
gain. 

 
FCC NOTE 

The product has been tested and found to comply with the Booster requirements per FCC 
Part 20.  

 
IC NOTE 

The product has been tested and found to comply with the Industry Canada (IC) RF Exposure 
Requirements, pursuant to IC RSS-131. 

 
NOTE 

The Manufacturer’s rated output power of this equipment is for single carrier operation. For 
situations when multiple carrier signals are present, the rating would have to be reduced by 
3.5 dB, especially where the output signal is re-radiated and can cause interference to 
adjacent band users. This power reduction is to be by means of input power or gain reduction 
and not by an attenuator at the output of the device. 

RF EXPOSURE WARNING- FCC 

The ERP limit, as defined by the FCC is +37 dBm. In order to comply with the FCC RF 
exposure requirements, the antenna installation must comply with the following: 
The Omni directional antenna (or leaky cable) must be installed so as to provide a 

minimum 

separation distance of at least 29.9 cm (~11.8  inches) between the antenna connected to the 
RF booster and the human user’s body within the area. (This assumes an antenna with gain 

of 0 dBi, VSWR ≤ 2:1, Zo= 50 ohms and a cable attenuation less then 1dB).

 

Should user choose to utilize a higher gain antenna (greater than 0 dBi) with the system, 
attenuation of the BDA’s gain will be required to meet FCC ERP limit of +37 dBm. 
 

RF EXPOSURE WARNING- INDUSTRY CANADA 

In order to comply with the IC RF exposure requirements, the antenna installation must 
comply with the following: 
For 0 dBi gain antenna: The antenna must be installed so as to provide a 

minimum 

separation distance of at least 39.5 cm (~15.6inches)  between the antenna connected to the 

RF booster and the human user’s body within the area. (VSWR ≤ 2:1, Zo= 50 ohms and a 

cable attenuation less then 1dB). 
For 10 dBi gain antenna: The antenna must be installed so as to provide a 

minimum 

separation distance of at least 124.9 cm (~49.2 inches)  between the antenna connected to 

the RF booster and the human user’s body within the area. (VSWR ≤ 2:1, Zo= 50 ohms an

d a 

cable attenuation less then 1dB). 

Содержание BDA-SMR/N-37

Страница 1: ...Installation and Operating Manual BDA SMR N 37 37 90 AB SMR N Bi Directional Amplifier ...

Страница 2: ...ARNING INDUSTRY CANADA 4 ELECTRICAL SPECIFICATIONS 6 MECHANICAL SPECIFICATIONS 6 ENVIRONMENTAL CONDITIONS 6 MECHANICAL OUTLINE 8 CONNECTIONS 9 AVAILABLE OPTIONAL FEATURES 11 ALARM CONDITIONS 12 VARIABLE GAIN ADJUSTMENT AND LED INDICATORS 13 INSTALLATION 14 OPERATION 15 DIAGNOSTICS GUIDE 16 ANTENNA SEPERATION 16 APPENDIX 1 17 APPENDIX 2 19 ...

Страница 3: ...ment shouldn t be used if this protection is impaired The supplied power cord must be used along with an uninterrupted external power source HAZARDOUS LINE AND RF VOLTAGES This symbol is marked on the equipment where dangerous voltages are present Use extreme caution Both RF input and output connectors should be terminated prior to the application of the external AC source Otherwise contact with t...

Страница 4: ... EXPOSURE WARNING FCC The ERP limit as defined by the FCC is 37 dBm In order to comply with the FCC RF exposure requirements the antenna installation must comply with the following The Omni directional antenna or leaky cable must be installed so as to provide a minimum separation distance of at least 29 9 cm 11 8 inches between the antenna connected to the RF booster and the human user s body with...

Страница 5: ...enuator gives 0 30 dB of attenuation in 2 dB steps The use of these controls is covered in the OPERATION section later in this document BLOCK DIAGRAM DESCRIPTION Figure 1 Block Diagram 1 Diplexer Separates Combines UL and DL pass bands provides needed isolation and selectivity to support system gain 2 Downlink Low noise amplifier and driver Exhibits low noise figure and high linearity 3 Downlink F...

Страница 6: ...CIFICATIONS Size 16 4 x8 x15 3 RF Connectors N Type Female Weight 37 8 Lb ENVIRONMENTAL CONDITIONS The unit is designed for indoor applications Operating temperature 30 C to 55 C Storage temperature 40 C to 85 C Composite Output Power 25 dBm 27 dBm 33 dBm 37 dBm Gain Flatness dB 1 5 2 0 1 5 1 5 Noise Figure dB 5 0 Max 4 5 Typ 5 0 Max 4 5 Typ 5 0 Max 4 5 Typ 5 5 Max 5 0 Typ Output Power ALC Set dBm...

Страница 7: ...tion OutputComposite Power Typical DC Current Draw 24VDC A Battery Back Up Time Hours Recommend Battery Rated Capacity 20 Hour Rate Amp Hours 37 dBm 3 55 4 17 75 8 35 5 12 53 25 24 106 5 33 dBm 2 47 4 12 35 8 24 7 12 37 05 24 74 1 31 dBm 2 35 4 11 75 8 23 5 12 35 25 24 70 5 27 dBm 2 1 4 10 5 8 21 12 31 5 24 63 Note We do not guarantee specifications under Battery Back Up power ...

Страница 8: ...8 P a g e MECHANICAL OUTLINE Figure 3 Mechanical Outline ...

Страница 9: ...ctions must be made through cables with characteristic impedance of 50 ohms The BDA AC power is accepted through a standard 3 wire male plug IEC 320 with phase neutral and ground leads The AC power is wired to a high efficiency DC switching power supply which is CE and UL approved The power supply runs the amplifiers and the LED indicators The metal enclosure of the BDA is connected to ground Addi...

Страница 10: ...10 P a g e CONNECTIONS Cont Figure 4b Back Panel Connections ...

Страница 11: ...er failure Local Alarming via dry contact 9 Pin Connector RM9 A 9 Pin dry contact will be provided to hard wire into a building s alarm system Dry contact will provide alarms for ALC and amplifier failure Local Alarming via dry contact 26 Pin Connector 026 A 26 Pin dry contact will be provided to hard wire into a building s alarm system Dry contact will provide alarms for ALC amplifier failure don...

Страница 12: ...arm monitors the current of both the uplink and downlink amplifiers An alarm condition will occur if either the uplink or downlink amplifiers are over or under its current tolerance Additionaly each failure alarm indicator from the available features can be monitored via an alarm monitoring connector 3 contacts per each alarm The following diagram shows a Non Alarm condition If an alarm occurs the...

Страница 13: ...LC set UL Alarm Illuminates when the UL amplifier fails External DC LED optional Illuminates when the BDA is operating from a DC source Oscillation detection LED optional Illuminates when oscillation is detected Donor antenna alarm LED optional Illuminates when Donor Antenna is disconnected Mobile antenna alarm LED optional Illuminates when the mobile port is disconnected DL Manual Gain Attenuator...

Страница 14: ...s than the BDA gain will give rise to oscillations which will saturate the amplifiers and possibly cause damage to the BDA 3 Connect the cable from the donor antenna to the BDA connector labeled BASE and the cable from the service antennas to the BDA connector labeled MOBILE 4 See main Panel of the BDA and verify that both of the Uplink and Downlink attenuation is set to 30 dB via dial Attenuator ...

Страница 15: ...ification ALC function is located in each power amplifier A red LED indicator located on the Front main panel see figure 5 illuminates when output power meets or exceeds the ALC preset point To establish proper operating gain on the Uplink and Downlink sides start with the Downlink Observe the red LED indicator on the Downlink amplifier Units are shipping with maximum attenuation Decrease attenuat...

Страница 16: ...een those antennas is 15db above the system gain The amount of isolation that can be achieved between antennas depends on several factors such as the physical vertical and horizontal separation distance between the antennas polarization radiation pattern of the antennas the medium between the antennas antenna gain etc Antenna isolation can most accurately be determined through on site measurements...

Страница 17: ...ctors Figure 7a If the donor antenna does not short please connect G Way s special Donor Short Simulator Please note if you intend to use other components i e Lightning Protector between the base port and donor antenna make sure they have an open short N Type Female Female Donor Short Simulator N Type Male Female Donor Short Simulator Figure 7b Conditions for DC Backup Alarm The alarm monitors the...

Страница 18: ...18 P a g e Alarm Block Diagram ...

Страница 19: ...etween horizontally separated transmitter and receiver antennas dh m the horizontal distance from the centre of interferer antenna to that of the interfered with receiver antenna dv m the vertical distance from the interferer antenna to the interfered with receiver antenna measured from radiation centre to radiation centre f Hz the wavelength of the interfered with system frequency band GTx dBi ga...

Отзывы: