INSTALLATION 

 
 
DO NOT APPLY A.C. POWER TO THE UNIT  UNTIL CABLES ARE 
CONNECTED TO BOTH PORTS OF THE BDA AND THE ANTENNAS.  

 
 
1. 

Set the BDA on the floor or mount on a wall (where applicable). Using appropriate screws 

and anchors, attach the BDA to the wall at the four mounting holes on the side flanges. 
(Special version not shown in this manual).

 

 

2. Ensure that the isolation between the base station antenna and the mobile antenna 
should be at least 12 dB higher than the BDA gain  (Use the higher of the Uplink and 
Downlink gains reported on the BDA test data sheet).

 

 Isolation less than this value can cause gain ripple across the band. Isolation equal to 
or less than the BDA gain will give rise to oscillations which will saturate the amplifiers 
and possibly cause damage to the BDA.  

 

3. Connect the cable from the donor antenna to the BDA connector labeled “BASE” and the 
cable from the service antennas to the BDA connector labeled “MOBILE”. 
 
4. See main Panel of the BDA and verify that both of the Uplink and Downlink attenuation is 
set to 30 dB via dial Attenuator.   
 
5.  Connect the AC power cord to the BDA and then to the power source. Verify that the 
“Power ON” lamp is illuminated.  
 
Installation of the BDA is now complete. To adjust the gain controls to suit the specific signal 
environment, refer to the next section of the manual. 

 

Note:

 

For repeat installations of existing equipment, make sure the attenuation is 

positioned to its maximum setting (30 dB). After verification attenuation, follow the 
above steps starting with step 1. 

 
 

Содержание BDA-PS9-37/37-90-C

Страница 1: ...Installation and Operating Manual BDA PS9 37 37 90 C 900MHz Band Bi Directional Amplifier...

Страница 2: ...ADA 5 GENERAL DESCRIPTION 5 ELECTRICAL SPECIFICATIONS 6 MECHANICAL SPECIFICATIONS 6 ENVIRONMENTAL CONDITIONS 6 MECHANICAL OUTLINE 8 CONNECTIONS 9 AVAILABLE OPTIONAL FEATURES 10 ALARM CONDITIONS 11 VAR...

Страница 3: ...ent shouldn t be used if this protection is impaired The supplied power cord must be used along with an uninterrupted external power source HAZARDOUS LINE AND RF VOLTAGES This symbol is marked on the...

Страница 4: ...terference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L expl...

Страница 5: ...GENERAL DESCRIPTION The downlink path of BDA receives RF signals from the base station amplifies the signal and transmits the signal without changing the frequency into a Distributed Antenna System at...

Страница 6: ...see spec for more accurate information Size 14 x 6 7 x18 1 RF Connectors N Type Female Weight 37 8 lb ENVIRONMENTAL CONDITIONS The unit is designed for indoor applications Operating temperature 30 C t...

Страница 7: ...al Battery Back Up Configuration Output Composite Power Typical DC Current Draw 24VDC A Battery Back Up Time Hours Recommend Battery Rated Capacity 20 Hour Rate Amp Hours 37 dBm 3 55 4 17 75 8 35 5 12...

Страница 8: ...8 P a g e Note We do not guarantee specifications under Battery Back Up power MECHANICAL OUTLINE...

Страница 9: ...The RF connections must be made through cables with characteristic impedance of 50 ohms The BDA AC power is accepted through a standard 3 wire male plug IEC 320 with phase neutral and ground leads Th...

Страница 10: ...to a building s alarm system Dry contact will provide alarms for ALC and amplifier failure Local Alarming via dry contact 26 Pin Connector 026 A 26 Pin dry contact will be provided to hard wire into a...

Страница 11: ...ector prohibits an individual from accidentally pulling AC cord from unit as well as providing additional protection against direct water ALARM CONDITIONS The alarm monitors the current of both the up...

Страница 12: ...the ALC set UL Alarm Illuminates when the UL amplifier fails External DC LED optional Illuminates when the BDA is operating from a DC source Oscillation detection LED optional Illuminates when oscilla...

Страница 13: ...he band Isolation equal to or less than the BDA gain will give rise to oscillations which will saturate the amplifiers and possibly cause damage to the BDA 3 Connect the cable from the donor antenna t...

Страница 14: ...s located in each power amplifier A red LED indicator located inside the BDA enclosure see figure 5 illuminates when output power meets or exceeds the ALC preset point To establish proper operating ga...

Страница 15: ...en those antennas is 15db above the system gain The amount of isolation that can be achieved between antennas depends on several factors such as the physical vertical and horizontal separation distanc...

Страница 16: ...nect G Way s special Donor Short Simulator Please note if you intend to use other components i e Lightning Protector between the base port and donor antenna make sure they have an open short N Type Fe...

Страница 17: ...17 P a g e APPENDIX 1 O26 Alarm Block Diagram...

Страница 18: ...tween horizontally separated transmitter and receiver antennas dh m the horizontal distance from the centre of interferer antenna to that of the interfered with receiver antenna dv m the vertical dist...

Отзывы: