background image

 

 

 

 
 

Installation 

and

 

Operating Manual 

 

 

 

BDA-PS7W/PS8NEPS-37/37-90-C 
BDA-PS7/PS8-37/37-90-C  

Public Safety 700/800 MHz Band Bi-Directional Amplifier  

 

 

Содержание BDA-PS7W/PS8NEPS-37/37-90-C

Страница 1: ...Installation and Operating Manual BDA PS7W PS8NEPS 37 37 90 C BDA PS7 PS8 37 37 90 C Public Safety 700 800 MHz Band Bi Directional Amplifier...

Страница 2: ...NDUSTRY CANADA 4 ELECTRICAL SPECIFICATIONS 6 MECHANICAL SPECIFICATIONS 6 ENVIRONMENTAL CONDITIONS 6 MECHANICAL OUTLINE 8 CONNECTIONS 9 AVAILABLE OPTIONAL FEATURES 10 ALARM CONDITIONS 11 VARIABLE GAIN...

Страница 3: ...ent shouldn t be used if this protection is impaired The supplied power cord must be used along with an uninterrupted external power source HAZARDOUS LINE AND RF VOLTAGES This symbol is marked on the...

Страница 4: ...by an attenuator at the output of the device RF EXPOSURE WARNING FCC The ERP limit as defined by the FCC is 37 dBm In order to comply with the FCC RF exposure requirements the antenna installation mu...

Страница 5: ...attenuator gives 0 30 dB of attenuation in 2 dB steps The use of these controls is covered in the OPERATION section later in this document BLOCK DIAGRAM DESCRIPTION Figure 1 Block Diagram 1 Triplexer...

Страница 6: ...CAL SPECIFICATIONS May vary per unit see spec for more accurate information Size 14 x 6 7 x18 1 RF Connectors N Type Female Weight 37 8 lb ENVIRONMENTAL CONDITIONS The unit is designed for indoor appl...

Страница 7: ...utput Composite Power Typical DC Current Draw 24VDC A Battery Back Up Time Hours Recommend Battery Rated Capacity 20 Hour Rate Amp Hours 37 dBm 3 55 4 17 75 8 35 5 12 53 25 24 106 5 33 dBm 2 47 4 12 3...

Страница 8: ...8 P a g e MECHANICAL OUTLINE Figure 3 Mechanical Outline...

Страница 9: ...tions must be made through cables with characteristic impedance of 50 ohms The BDA AC power is accepted through a standard 3 wire male plug IEC 320 with phase neutral and ground leads The AC power is...

Страница 10: ...to a building s alarm system Dry contact will provide alarms for ALC and amplifier failure Local Alarming via dry contact 26 Pin Connector 026 A 26 Pin dry contact will be provided to hard wire into a...

Страница 11: ...individual from accidentally pulling AC cord from unit as well as providing additional protection against direct water ALARM CONDITIONS The alarm monitors the current of both the uplink and downlink...

Страница 12: ...lluminates when the UL amplifier fails External DC LED optional Illuminates when the BDA is operating from a DC source Oscillation detection LED optional Illuminates when oscillation is detected Donor...

Страница 13: ...than the BDA gain will give rise to oscillations which will saturate the amplifiers and possibly cause damage to the BDA 3 Connect the cable from the donor antenna to the BDA connector labeled BASE a...

Страница 14: ...ction is located in each power amplifier A red LED indicator located inside the BDA enclosure see figure 5 illuminates when output power meets or exceeds the ALC preset point To establish proper opera...

Страница 15: ...en those antennas is 15db above the system gain The amount of isolation that can be achieved between antennas depends on several factors such as the physical vertical and horizontal separation distanc...

Страница 16: ...nect G Way s special Donor Short Simulator Please note if you intend to use other components i e Lightning Protector between the base port and donor antenna make sure they have an open short N Type Fe...

Страница 17: ...17 P a g e APPENDIX 1 O26 Alarm Block Diagram...

Страница 18: ...tween horizontally separated transmitter and receiver antennas dh m the horizontal distance from the centre of interferer antenna to that of the interfered with receiver antenna dv m the vertical dist...