P a g e

 

 

 

 

 

 

 

 

SAFETY OPERATION INSTRUCTIONS

 

 

BEFORE USE

 

Review  this  manual and  insure  that  all conditions  are  compatible  with 
the amplifier's  specifications.  Safe  operation  may be impaired  if  this 
equipment is not used as intended. 

 

GENERAL DESCRIPTION

 

This  symbol  is  marked  in  the  manual  and denotes  important  safety 
operation instructions. Please read carefully before continuing. 
This  equipment  is  suitable  for  a  wide  variety  of  scientific,  industrial, 
laboratory  and  communication  applications  where  high  levels  of 
electromagnetic  Radio Frequency 

(RF) 

energy 

are 

required. 

Therefore,  the  output  of  the  amplifier  must  be  terminated  to  an 
appropriate  load,  such as  a  high  power  attenuator, dummy  load,  a 
communication  or  radiation  antenna.  User  must  insure  that  radiated 
energy do not violate regulatory levels of electromagnetic interference. 

 

PROTECTIVE GROUND

 

This symbol is marked on the equipment and denotes protective ground 
terminal. 
This  amplifier  includes protective  ground  terminal.  The  equipment 
shouldn't be used if this protection is impaired. The supplied power cord 
must be used along with an uninterrupted external power source. 

 

HAZARDOUS LINE AND RF VOLTAGES

 

This symbol is marked on the equipment where dangerous voltages are 
present. Use extreme caution. 
Both RF input and  output connectors should be terminated prior to the 
application  of  the  external  AC  source.  Otherwise,  contact  with  the 
RF  output  center  pin  can  be  dangerous.  Place  the  amplifier  in  the 
OFF  position  prior  to connecting and disconnecting RF output load. 

 

ELECTROSTATIC DISCHARGE (ESD)

 

This symbol is marked on the equipment where ESD sensitive devices 
are present. Do not handle without the proper protection. 

 

MAINTENANCE

 

Maintenance,  repair  and  calibration  must  be  performed by qualified 
personnel only. Contact with the internal amplifier components maybe 
dangerous even when the equipment is in the OFF position. 

 

CAUTION

          This  denotes  a  condition  that  may cause  damage  to  the  Amplifier  if 

procedure  is  not  correctly performed.  Do  not  proceed  until  the 
indicated conditions are met.

 

 

FORCED AIR COOLING

 

Do not block the inlet and outlet of the internal cooling blowers. 
Otherwise damage may result to the amplifier. 

Содержание BDA-PS7W-37/37-90-R

Страница 1: ...Installation and Operating Manual BDA PS7W 37 37 90 R PS700 Band Bi Directional Amplifier ...

Страница 2: ...ARNING INDUSTRY CANADA 4 ELECTRICAL SPECIFICATIONS 6 MECHANICAL SPECIFICATIONS 6 ENVIRONMENTAL CONDITIONS 6 MECHANICAL OUTLINE 8 CONNECTIONS 9 AVAILABLE OPTIONAL FEATURES 10 ALARM CONDITIONS 11 VARIABLE GAIN ADJUSTMENT AND LED INDICATORS 12 INSTALLATION 13 OPERATION 14 DIAGNOSTICS GUIDE 15 ANTENNA SEPERATION 15 APPENDIX 1 16 APPENDIX 2 18 ...

Страница 3: ...ment shouldn t be used if this protection is impaired The supplied power cord must be used along with an uninterrupted external power source HAZARDOUS LINE AND RF VOLTAGES This symbol is marked on the equipment where dangerous voltages are present Use extreme caution Both RF input and output connectors should be terminated prior to the application of the external AC source Otherwise contact with t...

Страница 4: ...e device RF EXPOSURE WARNING FCC The ERP limit as defined by the FCC is 37 dBm In order to comply with the FCC RF exposure requirements the antenna installation must comply with the following The Omni directional antenna or leaky cable must be installed so as to provide a minimum separation distance of at least 30 8 cm 12 2 inches between the antenna connected to the RF booster and the human user ...

Страница 5: ...ttenuator gives 0 30 dB of attenuation in 2 dB steps The use of these controls is covered in the OPERATION section later in this document BLOCK DIAGRAM DESCRIPTION Figure 1 Block Diagram 1 Diplexer Separates Combines UL and DL pass bands provides needed isolation and selectivity to support system gain 2 Downlink Low noise amplifier and driver Exhibits low noise figure and high linearity 3 Downlink...

Страница 6: ...Amps 50 to 60 Hz MECHANICAL SPECIFICATIONS Size 15 x19 x5 2 RF Connectors N Type Female Weight 35 Lb ENVIRONMENTAL CONDITIONS The unit is designed for indoor applications Operating temperature 30 C to 55 C Storage temperature 40 C to 85 C Composite Output Power 25 dBm 27 dBm 33 dBm 37 dBm Gain Flatness dB 1 5 2 0 1 5 1 5 Noise Figure dB 5 0 Max 4 5 Typ 5 0 Max 4 5 Typ 5 0 Max 4 5 Typ 5 5 Max 5 0 T...

Страница 7: ...tion Output Composite Power Typical DC Current Draw 24VDC A Battery Back Up Time Hours Recommend Battery Rated Capacity 20 Hour Rate Amp Hours 37 dBm 3 55 4 17 75 8 35 5 12 53 25 24 106 5 33 dBm 2 47 4 12 35 8 24 7 12 37 05 24 74 1 31 dBm 2 35 4 11 75 8 23 5 12 35 25 24 70 5 27 dBm 2 1 4 10 5 8 21 12 31 5 24 63 Note We do not guarantee specifications under Battery Back Up power ...

Страница 8: ...8 P a g e MECHANICAL OUTLINE Figure 3 Mechanical Outline ...

Страница 9: ...ections must be made through cables with characteristic impedance of 50 ohms The BDA AC power is accepted through a standard 3 wire male plug IEC 320 with phase neutral and ground leads The AC power is wired to a high efficiency DC switching power supply which is CE and UL approved The power supply runs the amplifiers and the LED indicators The metal enclosure of the BDA is connected to ground Add...

Страница 10: ...er failure Local Alarming via dry contact 9 Pin Connector RM9 A 9 Pin dry contact will be provided to hard wire into a building s alarm system Dry contact will provide alarms for ALC and amplifier failure Local Alarming via dry contact 26 Pin Connector 026 A 26 Pin dry contact will be provided to hard wire into a building s alarm system Dry contact will provide alarms for ALC amplifier failure don...

Страница 11: ...arm monitors the current of both the uplink and downlink amplifiers An alarm condition will occur if either the uplink or downlink amplifiers are over or under its current tolerance Additionaly each failure alarm indicator from the available features can be monitored via an alarm monitoring connector 3 contacts per each alarm The following diagram shows a Non Alarm condition If an alarm occurs the...

Страница 12: ...when the UL amplifier fails External DC LED optional Illuminates when the BDA is operating from a DC source Oscillation detection LED optional Illuminates when oscillation is detected Donor antenna alarm LED optional Illuminates when Donor Antenna is disconnected Mobile antenna alarm LED optional Illuminates when the mobile port is disconnected DL Manual Gain Attenuator Is a switch used for DL gai...

Страница 13: ... gain will give rise to oscillations which will saturate the amplifiers and possibly cause damage to the BDA 3 Connect the cable from the donor antenna to the BDA connector labeled BASE and the cable from the service antennas to the BDA connector labeled MOBILE 4 See main Panel of the BDA and verify that both of the Uplink and Downlink attenuation is set to 30 dB via dial Attenuator 5 Connect the ...

Страница 14: ...C function is located in each power amplifier A red LED indicator located on the Front main panel see figure 5 illuminates when output power meets or exceeds the ALC preset point To establish proper operating gain on the Uplink and Downlink sides start with the Downlink Observe the red LED indicator on the Downlink amplifier Units are shipping with maximum attenuation Decrease attenuation one step...

Страница 15: ...een those antennas is 15db above the system gain The amount of isolation that can be achieved between antennas depends on several factors such as the physical vertical and horizontal separation distance between the antennas polarization radiation pattern of the antennas the medium between the antennas antenna gain etc Antenna isolation can most accurately be determined through on site measurements...

Страница 16: ...ctors Figure 7a If the donor antenna does not short please connect G Way s special Donor Short Simulator Please note if you intend to use other components i e Lightning Protector between the base port and donor antenna make sure they have an open short N Type Female Female Donor Short Simulator N Type Male Female Donor Short Simulator Figure 7b Conditions for DC Backup Alarm The alarm monitors the...

Страница 17: ...17 P a g e Alarm Block Diagram ...

Страница 18: ...etween horizontally separated transmitter and receiver antennas dh m the horizontal distance from the centre of interferer antenna to that of the interfered with receiver antenna dv m the vertical distance from the interferer antenna to the interfered with receiver antenna measured from radiation centre to radiation centre f Hz the wavelength of the interfered with system frequency band GTx dBi ga...

Отзывы: