Output fault
Output short circuit or off
9.2 Troubleshooting
9.2.1
Parameter configuration fault
Reconfigure the working parameters of the radar through the upper computer and transmit them to the
machine
。
9.2.2
Front lens cover fault
The front mirror cover is an important part of LSD1xxA. If the front mirror cover is polluted,
the measurement light will be affected, and the measurement error will be large if it is serious.
Therefore, the front mirror cover must be kept clean. When the front mirror cover is found dirty,
please use a soft cloth dipped with neutral detergent to wipe in the same direction. When there are
particles on the front mirror cover, blow them off with gas first, and then wipe them to avoid
scratching the mirror cover.
9.2.3
Measurement reference fault
The measurement reference is to verify whether the measurement data is valid. If there is a fault,
it means that the measurement data of the machine is not accurate and cannot be used any more. It
needs to be returned to the factory for maintenance
.
9.2.4
Motor fault
Failure of the motor will cause the machine to fail to scan for measurement or result in
inaccurate response time. Need to return to factory for maintenance
。
9.2.5
Communication fault
Check the communication cable or machine failure
9.2.6
Output fault
Check the wiring or machine failure