G-Tek 7 Series Скачать руководство пользователя страница 4

 

 

3-3 

G-Tek Corporation 

Introduction 

 

3

 

I

NTRODUCTION

 

This manual is written to help the user to familiarize with the installation and operation of the GSM 
Dialer.  The  GSM  Dialer  SMS  &  voice  auto-dialing  system  which can  be  used  to communicate  Alert 
activity  from  an  existing  alarm  system  or  from  sensors  connected  to  its  inputs  as  a  standalone 
communicator.  The  device  supports  remote  Arming,  Disarming,  and  Partial  Disarming  changes  by 
admin. 
Alerts  are  processed  according to  the priority set by user and download  Alert Log details using PC 
application. 

3.1

 

M

ANUAL 

L

AYOUT

 

This manual is divided into a number of sections for quick and easy reference.  

Table 1 Manual Layout 

Section 1 Introduction 

This gives outline of the manual, brief description about the GSM 
Dialer, Optional features available and how to unpack it. 

Section 2 Installation 

This  section  gives  the  details  of  the  LED  display  And  Electrical 
Installation. 

Section 3 Operation 

This section gives the details of the GSM alert report and arming-
Disarming feature. 

Section 4 
GSM Dialer Configuration 

This section gives the details of various parameter that user can set 
for proper monitoring requirement. 

Section  5  Calibration  of  GSM 
signal strength  

This  section  describes  the  calibration  procedure  for  the  GSM 
Dialer. 

Section 6 
Troubleshooting Guide 

This section describes about the most frequently asked questions 
and their solutions about GSM Dialer. 

Section 7 Accessories 

This section describes the standard accessories for the GSM Dialer. 

Section 8 Specification 

It describes the detailed specification of the GSM Dialer. 

Section 9 Ordering Code 

It describe the details of order code and comparing it with the code 
on the GSM Dialer, user can find out the installed options.

 

 

*Features and capabilities may vary depending upon the product purchased.  

3.2

 

GSM

 

D

IALER 

D

ESCRIPTION 

 

GSM Dialer support up to 20 Alert messages and 4 different voice call, user can store up to 20 contact 
numbers and set alert priority using PC Application it process upcoming alert base on it set priority 
and if high priority alert come during low priority process it terminates low priority process and start 
services high priority alert, device support remote arming, disarming and partial disarming request by 
admin only. Alert log details user can download using PC application. 

3.3

 

O

PTIONAL 

F

EATURES

 

Following optional features are available for this GSM Dialer. 

 

Support up to 20 contact number  

 

15 alert messages and 4 different  voice call  

 

Alert process base on set priority  

 

Event log details and Alert log detail using PC Application. 

Содержание 7 Series

Страница 1: ...GSM Alert System Model No 7xx G Tek Corporation Pvt Ltd 3 mahavir estate karelibaug vadodara 390 018 tel 91 265 2461912 email info gtek india com url www gtek india com OPERATING MANUAL...

Страница 2: ...s 5 8 5 1 4 Rechargeable Battery Backup Connection 5 9 5 1 5 USB and Relay connection 5 10 6 Operation 6 11 6 1 Alert message and call based on priority 6 11 6 2 Process Arming Disarming and partial D...

Страница 3: ...llation 5 6 Figure 4 Mains supply connection 5 8 Figure 5 Alert Inputs 5 8 Figure 6 USB Cable and Relay Connection 5 10 Figure 7 Recording and playback 8 15 Figure 8 USB endpoints actually reside on t...

Страница 4: ...GSM signal strength This section describes the calibration procedure for the GSM Dialer Section 6 Troubleshooting Guide This section describes about the most frequently asked questions and their solut...

Страница 5: ...atched in a recyclable environment friendly package specially designed to give adequate protection during transit If the outer box show sign of damage it should be opened immediately and the GSM Diale...

Страница 6: ...4 5 G Tek Corporation System architecture Figure 2 System Architecture 4 SYSTEM ARCHITECTURE GSM Modem Controller Power supply section Voice storage System Indicators Relay Input alerts Antenna SIM...

Страница 7: ...ommendation LED Indication Indicate communications status with two way pager network Battery Sleep mode backup for RTC Recommended battery CR2032 DB9 Telephone Jack Voice recording and listing Antenna...

Страница 8: ...ipment may be impaired All equipment connected to the instrument s terminals must comply with local safety standards IEC 60950 EN601010 1 NOTE In order to ensure maximum GSM Dialer performance proper...

Страница 9: ...aptor connected to mains connector else other option for power supply through 2pin relimate female Ensure that the end of adaptor connector is fully inserted into the mains connector and no loose poor...

Страница 10: ...lp when you are away used to monitor burglar alarm fire alarm motion detection fuel levels temperature changes humidity levels pressure switches Vibration low or high voltage glass breakage control sy...

Страница 11: ...e end of Mini USB cable to the USB port of the GSM dialer as shown in figure 6 And other end to the computer for communicate using USB 12 core wire in stranded form is the minimum requirement for rela...

Страница 12: ...alert priority set by user using PC application Message and voice call sending restriction is possible for particular contact number also one can change the alert message string using PC Application...

Страница 13: ...minutes system get disarm according to time request from admin then automatic arm If any pending alerts remains before acceptation of partial disarm command it automatic starts services pending work...

Страница 14: ...ring false command sent Following are the Errors generated regarding protocol malfunction 1 ERROR 01 Invalid Command Code 2 ERROR 02 Invalid Phone Number 3 ERROR 03 Invalid Syntax 4 ERROR 04 Invalid I...

Страница 15: ...nding Machine Security Pumping Stations Tanks Oil and Water Levels Buildings and Real Estate Weather Stations River Monitoring Flood Control Fridges Freezers Fish Tanks Tropical Tanks Farming Machiner...

Страница 16: ...entries and messages For admin number and other configuration is PC Application base refer GSM view log manual WARNING DO NOT Insert or remove the SIM card while the GSM Dialer is powered 8 2 RECORDIN...

Страница 17: ...cated by MICG LED alongside Phone Jack The message recording will continue until the message pin released or the voice IC will play beep tone to indicate the message record finished or if user want to...

Страница 18: ...Play Operating system software automatically identifies configures and loads the appropriate device driver when a user connects a USB device Expandability Up to 127 different peripheral devices may th...

Страница 19: ...Strength Calibration Sr No Value RSSI dBm Condition And Bars color in PC Application 100 times 1 2 109 Marginal 0 2 3 107 357 3 4 105 714 4 5 103 1071 5 6 101 1428 6 7 99 1785 7 8 97 2142 8 9 95 2499...

Страница 20: ...ble in GSM Dialer Refer to section 3 1 2 7 How and where to Connect USB cable in GSM Dialer Refer to section 3 1 4 8 How to supply power to GSM Dialer It is better to give an independent uninterrupted...

Страница 21: ...re are LED indication given If the Status LED is OFF that means GSM modem is off If the Network LED is blinking at 1 sec means network failure is there The Process LED is turn to RED from GREEN in cas...

Страница 22: ...mat the SIM by deleting all entries in it Set the SIM as per your requirements Start the GSM Dialer If the problem still persist contact support team 2 What are the possible error message that are rec...

Страница 23: ...n as well No Instead the Modem provides with RS232 connection USB and TCP IP 4 Is there any security regarding the entry of Phone number in phone book entry of GSM YES the first number in phone book h...

Страница 24: ...sible that remaining works of terminated low priority services after completion of high priority event No once low priority terminated due to low high priority after completion of high priority it sta...

Страница 25: ...in Specifications Electrical Characteristics Frequency Range MHz 800MHz 960MHz 1880MHz 1930MHz V S W R 2 0 Gain dBi 2 0 Polarization vertical Impedance Ohm 50 Maximum input power w 10 Mechanical Chara...

Страница 26: ...30V DC 1Amp Adaptor Input Voltage 200 240V AC 1Amp Operating Frequency 50 to 60Hz Output voltage 9 30V DC 1Amp 11 3 USB CABLE Figure 11 USB Cable 30cm USB 2 0 Cable 24 AWG copper USB Mini B to USB typ...

Страница 27: ...of all the error condition occurrences 9 Voice Recording Through microphone 10 No of Messages One 11 Arming Disarming User can activate deactivate GSM dialer by sending a SMS from Admin mobile number...

Страница 28: ...ies No Of Alerts GSM Interface Voice Message Power Alarm PC Interface 7 GSM 0 3 0 MSG 0 No ne 0 12V DC 0 None 0 USB 1 5 1 Call Msg 1 1 Voice Msg 1 Battery Backup 1 Buzzer 1 TCP IP 2 10 2 2 Voice Msg 2...

Отзывы: