Page 18
Parameter 8
Kid’s Transmitter Delay
Buttons won’t work for X seconds after performing a function. Reduces the noise and annoyance factor when
small children that just keep pressing the buttons.
Parameter 9
Out 3/4 Transmitter Key Configuration
Outputs 3 and 4 can be configured to operate from either the left side of the TX, under the Whistle and Bell keys,
or on the right side, under the Faster and Slower keys. We’ve found that using the left side for these functions
may avoid inadvertent speed changes. This option also allows for backwards compatibility with older transmitters,
labeled for the right side.
Parameter 10
Bell Configuration
This can be set for a momentary output to trigger a fixed length bell sequence, or a latched output which will tog-
gle the bell on or off with each key press.
Parameter 11/12
Out 3/4 Terminal Configurations
Output 3 and 4 can be configured for 4 different functions: Momentary Sound triggers (Terminal 7,8), Latching
Lights on/off (Terminals 7,8 - 250 ma max), Latching Lights on/off (Terminals 9,10 - 750 ma max), or Phoenix Un-
Couplers (Terminals 9,10). Out 3 activates both terminal 7 and 9. Out 4 activates both terminal 8 and 10. In most
cases you will only make one wiring connection to for Out 3, and one for Out 4.
Parameter 11 configures terminals 7 and 8 for either momentary sound trigger operation, or latching lights opera-
tion. Parameter 12 configures terminals 9 and 10 for either momentary Phoenix Un-Coupler operation, or latching
lights.
Warning:
If you have a Phoenix Un-Coupler connected to terminals 9 or 10, and you select Parameter 12 Latch-
ing, you will instantly destroy the Un-Coupler. Use Momentary only for Phoenix Un-Couplers (the default option).
Us
er
Programming / DIP Switch Programming Procedure
User configurable parameters can be programmed using the 4-position DIP switch, the on-board push-button next
to the DIP switch, and on-board LED.
Enter Programming Mode
Hold the button (next to the DIP switch) down on the RailBoss board until the LED goes out. Release the button.
The LED will begin flashing the option code of the selected parameter.
Select Parameter
Select the parameter you wish to view or program using the DIP switch. (the white square indicates position of the
switch; e.g. for parameter 0, all switches are in the down or off position.
View Current Option Code
The LED will repeatedly flash the option code for the currently selected parameter; e.g. two flashes followed by a
pause indicate option 2.
Change the Option Code
Momentarily press the push-button during the pause to advance the option to the next higher number, until you
get the desired number of flashes.
Save the Option Code
During the pause between code flashes, press and hold down the push-button for about 4 seconds until the LED
goes off. Upon release, the LED should stay on solid. This saves the option code and exits User Programming.
The new option will now be active.
Exit Programming Mode
To exit programming mode without saving any changes, turn off RailBoss power.