background image

Note: 

• If you want to adjust the intensity during a massage session, simply  

  press the “Intensity” button to select your desires intensity level.

• If you want to change the program during a massage session, you will 

  need to stop the current session by pressing the “Start/Stop” button. 

  Press the "Program" button to select new program mode, then press the 

  "Start/Stop" button to start the new session.

Applying the leg cuff :

Use the Ankle Indicator as alignment reference

Note :

• Switch off the device before wrapping the leg cuff around your leg.

• Do not apply or remove cuff when the chambers are inflated as it may 

  cause damage to the product.

• Application of leg cuff is the same for both legs

Ankle Indicator

Ankle Indicator

START MASSAGE PROGRAM

1. Slide the Safety Lock towards the [     ] unlock position to enable all 

    buttons. 

2. Press the “ON/OFF” button to start the device and the Power/Charge 

    Indicator LED will turn BLUE. Both the Program Indicator LED “P1” and 

    the Intensity Indicator LED “gentle” will be blinking. 

3. Press the “Program” button to select the desired program mode.

4. Press the “Intensity” button for intensity level selection.

5. Press the “Start/Stop” button again to start the massage session.

 

After the massage session has been completed, the user may press the 

“Start/Stop” button to repeat the same massage program, or press the 

“Program” or “Intensity” buttons to change the settings.

Once the device is shut off and is switched on again, all settings will be 

reset. Refer to steps 2 to 5 to change the settings.

Power Off :

The unit will shut off automatically about 5 minutes after the session is 

complete.

The user may also press and hold the “ON/OFF” button to shut off the 

device manually if necessary. The Power/Charge Indicator LED will be 

turned off.

OPERATING INSTRUCTIONS

Wrap the leg cuff around the calf according to the diagrams below

Note: 

• When the chamber is inflating, it is normal to hear a humming noise and 

  feel a tightening sensation around your leg.

• In the event of a pressure error or the chambers' pressure is unstable, all 

  the LEDs on the device will be turned on. Wait until all the chambers are 

  fully deflated before pressing any button.

P1: Rejuvenate Program (Wave Compression)

Sustained pressure for relief of tired legs after 

mild activity.

P2 : Relax Program (Massage) 

Gentle compressions, suitable for 

daily massage.

P3 : Recharge Program (Sequential Compression)

Enhances pressure with prolonged compressions 

for extremely tired legs.

Note:

• Please apply equal number of treatment sessions on both legs. 

• Do not go through more than two sessions continuously on one leg.

Dimensions :    

Controller : 102 x 134 x 35mm / 4” x 5.3” x 1.4” 

  Leg Cuff : 650 x 360mm / 25.6” x 14”

Weight :  

 

427 g

AC/DC Adaptor :  

AC input : 100-240V, 0.3A, 50/60Hz

  DC output : 5V 2A

Cuff size : 

 

27 to 50cm / 10.6” x 19.7”

Cuff Pressure :  

3 intensity levels (100 / 200 / 300 mmHg)

Massage Session Period : 

Approx. 10 minutes per session

Battery charging time : 

Approx. 2 hours

Operating time :  

Approx. 8 to 14 sessions per charge

Operating conditions :  

+5°C to 40°C

 

 

15-93 % relative humidity (non-condensing)

Storage conditions : 

-25°C to 70°C

  0-93 % relative humidity (non-condensing)

Symbol for the marking of electrical and electronics devices according to Directive 

2002/96/EC.

The device, accessories and the packaging have to be disposed of waste correctly at the 

end of the usage. Please follow Local Ordinances or Regulations for disposal.

MADE IN CHINA

P/N: 83-A0100-XXXXX-R

SELECTING MASSAGE PROGRAM

STORAGE AND MAINTENANCE

TECHNICAL SPECIFICATION

Cleaning :

• Switch off and disconnect the power adaptor before cleaning.

• The controller casing can be cleaned using a soft damp cloth and a mild 

  detergent. Do not use volatile liquids to clean the unit.

• Do not wash the leg cuff or immerse it in water. Do not use harsh 

  chemicals to clean the leg cuff to avoid damaging it.

About the battery :

• Do not open, disassemble, or service the battery pack. 

• Do not crush, puncture, short external contacts, or dispose of in fire or 

  water. 

• If the device will not be in use for an extended period of time, the battery 

  should be maintained by recharging regularly.

Safety lock :

When carrying or transporting the leg massager, you may disable all 

buttons by sliding the Safety Lock to [    ] lock position.

Alignment

Example: