- 2 -

SYMBOLS

 

The following symbols are used in this instruction manual, or 

appear on the device, accessories and packaging.

To assure correct use of the device, basic safety measures should 

always be followed including the warnings and cautions listed in 

this instruction manual.

DO NOT use this device on newborns, infants, children, 

toddlers or persons who cannot express their intentions.  The 

device is designed for use on adults only.

DO NOT self-diagnosis from the measurement results and 

start treatment by yourself.

DO NOT adjust medication based on the measurement results.

Consult your physician for specific information about your 

blood pressure.

The Irregular Heartbeat detection function may help to detect 

potential cardiac arrhythmia at an early stage but it is not 

intended to replace cardiac examination.

The “WHO Blood Pressure Classification” chart is a guide for 

reference and is not intended to replace medical diagnosis.

Use the device only as intended.  Do not use the device for 

any other purpose.

Do not apply the device on an arm with an unhealed wound or 

under medical treatment.

Do not take measurements more than necessary. High 

measurement repetition rates may cause pain, numbness, 

temporary red marks or bruising to the arm due to blood flow 

interference.

IMPORTANT NOTES

    Symbols 

Function / Meaning

 

WARNING / ATTENTION

 

Indicates a potentially hazardous situation which, if 

                         not avoided, could result in death or serious injury.

 

PRECAUTION / IMPORTANT INFORMATION

        SN 

Serial Number

 Manufacturer

 

Type BF: Device, cuff and tubing are designed to 

                          provide special protection against electrical shocks.

       SYS 

Systolic Blood Pressure in mmHg

       DIA 

Diastolic Blood Pressure in mmHg

       PUL Pulse

 

    EC Directive Medical Device Label

 

    WEEE Label

 

    Refer to instruction manual / booklet

 

    Keep dry

Содержание MD1100

Страница 1: ...E OPTIONAL AC ADAPTER 8 SETTING DATE AND TIME 9 BEFORE TAKING A MEASUREMENT 10 APPLYING ARM CUFF 10 PERFORMING BLOOD PRESSURE MEASUREMENT 11 RECALL AVERAGE AND PREVIOUS MEASUREMENT DATA 12 DELETE MEAS...

Страница 2: ...complies with EN ISO 81060 standard relating to non invasive sphygmomanom eters Part 1 Requirements and test methods for non automated measurement types and EN 1060 standard relating to non invasive...

Страница 3: ...lace cardiac examination The WHO Blood Pressure Classification chart is a guide for reference and is not intended to replace medical diagnosis Use the device only as intended Do not use the device for...

Страница 4: ...ay shorten the life of the part Dispose used equipment parts batteries and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution IMPORTANT...

Страница 5: ...nto any openings or hoses This may damage the unit Do not press the buttons with excessive force or with pointed objects IMPORTANT NOTES Do not wrap the cuff around body parts other than your upper le...

Страница 6: ...5 DEVICE DESCRIPTION Air Plug Air Tube Air Jack Battery Cover DC Jack Clock Key User 2 Key User 1 Key Main Unit Display Arm Cuff...

Страница 7: ...Indicator Pulse Rate Diastolic Pressure Systolic Pressure Irregular Heartbeat Indicator Date Time Severe Hypertension Moderate Hypertension Mild Hypertension High Normal Normal Optimal Pressure Bar Av...

Страница 8: ...use a choking hazard to children Store the batteries out of the reach of children In case battery fluid leaks do not touch the battery fluid Avoid skin contact e g put on protective gloves and clean t...

Страница 9: ...n the AC adapter is in use the main unit does not draw power from batteries 8 USE THE OPTIONAL AC ADAPTER The AC Adapter 6VDC 600mA is an optional accessory and is sold separately A Connecting the AC...

Страница 10: ...ey to confirm and then HOUR will start to blink 8 Press or key to set the current Hour 9 Press key to confirm and then MINUTE will start to blink 10 Press or key to set the current Minute 11 Press key...

Страница 11: ...lly tired or exhausted Remain still and do not talk during the measurement Position the cuff at heart level throughout the measurement Relax and sit comfortably on a chair Lay your feet flat on the fl...

Страница 12: ...ill deflate 5 The monitor automatically determines your ideal inflation level and will stop inflation automatically When inflation completes deflation will start automatically The device is measuring...

Страница 13: ...same user key to view previous measurement data Corresponding memory record number and time of measurement appear on the display 3 Press the same user key again to display the measurement data from m...

Страница 14: ...a snapshot of your blood pressure classification based on your measurements This will help you to understand what your blood pressure values mean Each segment of the bar indicator corresponds to the W...

Страница 15: ...nst the walls of the arteries Systolic pressure occurs when the heart contracts Diastolic pressure occurs when the heart expands Blood pressure is measured in millimeters of mercury mmHg One s natural...

Страница 16: ...ERROR code 3 E3 appears No pressure is detected The cuff may not fasten properly or too loose Reapply the cuff and fasten the cuff correctly ERROR code 5 E5 appears The cuff is over inflated Blood pr...

Страница 17: ...7 x 4 1 x 2 145 x 105 x 50mm Cuff Size Arm Circumference Range Standard 9 13 22cm 32cm Large 13 17 32cm 44cm Full Range 9 17 22cm 44cm Operating Temperature 41 F to 104 F 5 C to 40 C Operating Humidi...

Страница 18: ...The Sphygmomanometer MD1100 MD1120 MD1130 MD1150 MD1180 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby el...

Страница 19: ...intended for use in the electromagnetic environment specified below The customer of the user of Sphygmomanometer MD1100 MD1120 MD1130 MD1150 MD1180 should assure that it is used in such an environment...

Страница 20: ...00 MD1120 MD1130 MD1150 MD1180 should assure that it is used in such an environment Portable and mobile RF communications equipment should be used no closer to any part of the Sphygmomanometer MD1100...

Страница 21: ...be considered If the measured field strength in the location in which the Sphygmomanometer MD1100 MD1120 MD1130 MD1150 MD1180 is used exceeds the applicable RF compliance level above the Sphygmomanom...

Страница 22: ...ment in which radiated RF disturbances are controlled The customer or the user of the Sphygmomanometer MD1100 MD1120 MD1130 MD1150 MD1180 can help prevent electromagnetic interference by maintaining a...

Страница 23: ...22...

Страница 24: ...ning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betw...

Страница 25: ...ability to five 5 years from the original date of purchase at retail This warranty extends only to the original retail purchaser and is not transferable G LAB s sole liability from this warranty is li...

Отзывы: