FY-TECH FY-9000 Скачать руководство пользователя страница 3

P a g e . 1

Safety Precautions Symbols

Protect yourself and others from injury,
read and follow these precautions before 
installation and operation

.

E x p l o d i n g p a r t s c an i njure

.

Always w ear a f a c e 

s h i e l d a nd l ong s l e e ves

St a tic can damage PC boards
1

P u t on grounded wrist strap before

     handing boards or parts

2

U se prope r static-proof bags and boxes to

     store

move

 

or ship PC boar ds

1

Wea r ap p rov ed fa ce shiel d or safety goggles 

      with side shields

2

We a r pr ope r bod y protec tio n to protect skin

Do not weld in the  height

Rea d in s tru ction s

.

1

Re a d ow ner

'

s Manual be fore using or servicing 

   uni t

2

U se only manu fac turer ’ s su pplie d re p l a c e m e n t

Fly i ng meta l can in jure eyes

1)W e ar safet y glasse s with side shields or face 
  sh iel d

1

Mag n etic fi elds can affe ct pacemakers

.

     Pace m aker we arers keep away

.

2

Wea r ers shou ld consu lt their doctor before

     go i ng near plasma arc cutting operations

O v e r u s e c a n c ause o v erheating
A l l o w c ool i n g p eriod , follow r a ted d u t y c yc l e
b e f o r e s ta r t i n g

 

to w e l d a g a i n .

Electric shock can kill

:

1、

Do not touch live electrical parts

2、

Wear dry,hole-free insulating gloves and 

   body protection

.

3、

Do not wrap electrical cable around

 

your 

   body

.

4

Ground the workpiece with a good electr-

   ical ground

Eye protection for welding

:

Current level in amperage   Minimum shade
 Number
30-150A--------

--------------------  

#8

150-300A-------

-------------------- 

#10

300-500A----

--------------------

---

 

#12

Never cut

 

on pressurized cylinder

.

Maintenance regularly

Factory safety

Fire or explosion hazard

.

Do not locate unit on,over,or near combustibe 
surfaces.Do not install unit near flammables

.

Remove all flammables of the welding area

.

Falling unit can cause injury

.

The heat from the workpiece can cause serious

burns

Fumes and gas es can be ha zar d ous
welding produces fu mes an d gase s

.

 Br ea th in g

these fumes and ga se s ca n be haza r dou s 
to your he alt h 

.

If inside,ventilate the are a

.

Do not we l d in a co nf in ed sp ace only if it
 is well vent i lat e d

.

P ro te ct yourself

Warn others

Содержание FY-9000

Страница 1: ...Owner s Manual FY 9000 The equipment is approved by a number of car manufacturers...

Страница 2: ...4 Selecting a Location 5 Connecting Input Power 5 Operation 1 Controls 2 Welding Gun and Adaptors 3 Various Operations a Spot Welding b Washer Welding c Triangle Washer Welding d Carbon Rod Heating e...

Страница 3: ...near plasma arc cutting operations Overuse can cause overheating Allow cooling period follow rated duty cycle before starting to weld again Electric shock can kill 1 Do not touch live electrical parts...

Страница 4: ...res Volts IP X I1max I1eff 1 Rated maximum supply current Maximum effective supply current Degree of protection Single phase Duty cycle Direct current Constant crrent Temperature V S I O Suitable for...

Страница 5: ...tic vacuum cupule NO F001 Claw puller NO F004 Carbon Cod NO F007 Stud NO F016 Manual cupule NO F019 Back wheel NO F022 Spot welding electrode tip NO F008 Washer adaptor NO F011 Front part of puller NO...

Страница 6: ...ting AC6V 10V washer welding AC1V 12V double side welding AC1V 13V 57A 1 specifications Output voltage Input power Input current Operation way Time regulation system Operation place Vacuum cupule devi...

Страница 7: ...verheating Page 5 Overheating Stop working Wait fifteen minutes for unit to cool Reduce amperage or reduce duty cycle Weld again 0 15 A The welder is equipped with over hert protection On exceeding th...

Страница 8: ...ck the supplied of accessories according to packing list that attached to this manual 3 Properly install this equipment as following diagram Inspect the unit for any problems If so contact your local...

Страница 9: ...unit 2 Determine input power cord length according to its actual operation requirement Make sure that the supply cable is at 2 least 6mm indiameter 3 Do not move or operate unit where it could tip 4 U...

Страница 10: ...s Installation must meet all National and Local Codes have only qualified persons make this installation Disconnect and lockout tagount input power before connecting input conductors from unit Select...

Страница 11: ...9 10 6 7 1 LCD Display 2 Time adjustment Increase 3 Time adjustment Decrease 4 Current adjustment Increase 5 Current adjustment Decrease 6 Left 7 Up 8 Enter return 9 Right 10 Down 11 Power switch 12 N...

Страница 12: ...wire into the welded washers 1 Weld 2 washers on metal workpiece as close to welding area as possible 3 Located the holder on the welded washers 1 Electrode holder 2 Trigger Carbo Rod Shrinking OT Was...

Страница 13: ...ng can cause workpiece surface vehicle body damage Please weld other workpieces for practice before actual operations 2 Setting correct amperage and time according to the workpiece thickness 3 Continu...

Страница 14: ...ntinuing another operation is available after this procedure finished if not please shut off the main power supply and switch off the unit F017 F011 F020 b Washer Welding Set correct time Set correct...

Страница 15: ...workpiece surface vehicle body damage Please weld other workpieces for practice before actual operations 2 Setting correct amperage and time according to the workpiece thickness 3 Triangle washer wel...

Страница 16: ...correct time Remark 1 Setting amperage too high or time too long can cause workpiece surface vehicle body damage Please weld other workpieces for practice before actual operations 2 Setting correct a...

Страница 17: ...to the workpiece thickness 3 Continuing another operation is available after this procedure finished If not please shut off the main power supply and switch off the unit Wriggle Form Wire Welding Con...

Страница 18: ...in to lock the cupule on the dent 3 Slide the hammer to opposite direction to pull the dent out Pneumatic vacuum cupule 1 Connect gas air supply with the adaptor of cupule 2 Open the valve sticking cu...

Страница 19: ...oded view Page 17 Resistor Circuit board Main power switch Silicon control Control transformer Main transformer Left side view Resistor Control transformer Main transformer Right side view Capacitor a...

Страница 20: ...ot meet the requirement 4 Ground clamp bad contact 1 Increase amperage setting 2 Increase time setting 3 Replace input power cord 4 Change ground clamp location Piercing workpiece 1 output amperage to...

Страница 21: ...Page 19 23 0V...