FWE ASU-9 AIR SUPREMACY AIR SCREEN 

DELIVERY INSPECTIONS & ELECTRICAL REQUIREMENTS

PACKAGING:

Your Air Screen Refrigerator is shipped from the factory on a wooden pallet and packaged in a durable 
cardboard container. The carton is attached to the wooden skid with the use of large staples. These should
first be removed to avoid scratching the unit when lifting off the crate. Remove the wooden pallet and 
strapping material, and the unit should be rolled off the skid. Avoid laying the unit on its front, side or back 
for removal of the pallet.

NOTE: FWE does not recommend laying the unit down on its front, side or back. However, 
if you must, please be certain to allow the unit to remain in an upright position afterwards for 
48 hours before plugging the unit in or attempting to place the unit in to service, to assure 
that the compressor oils and refrigerant may settle.

FWE’S POLICY ON DAMAGED GOODS:

There are two types of damaged merchandise: VISIBLE DAMAGE AND CONCEALED DAMAGE.

A. CRATE HAS VISIBLE DAMAGE:
1. The product / crate being received is visibly damaged.
2. The receiver should 

refuse the damaged merchandise.

3. Receiver should 

sign the bill of lading indicating which merchandise 

is being "refused due to damage".

B. CONCEALED DAMAGE:
1. Merchandise is damaged and could not be externally detected.

Your receiving operation should inspect for this type of damage.

2.

Save all packing material

.

3. Contact FWE Customer Service 815-459-7500 and alert them to the situation.
4. Receiver must call the carrier to schedule an inspection of the damaged merchandise within

15 days

.

A. Check SERIAL PLATE to be sure the unit is installed on the proper NEMA plug 6-20P (on standard unit) 

electrical supply.

B. WARNING: This unit is provided with a three-pronged grounding plug. Be sure that the unit is plugged 

into a properly grounded outlet to avoid the possibility of electrical shock.

CORD & PLUG:

Your Air Screen Refrigerator is supplied with a cord & plug attached. It is shipped coiled at the bottom of 
the cabinet, secured by a nylon strip. For your safety and protection, all units supplied with a cord and plug
include a special three-prong grounding plug on the service cord. Select only a dedicated electrical outlet 
with grounding plug for power source. NOTE: Do not under any circumstances, cut or remove the round
grounding prong from the plug, or use an extension cord.

POWER SUPPLY:

The supply voltage should be checked prior to connection to be certain that proper voltage for the cabinet
wiring is available (refer to the serial tag to determine correct unit voltage). Make connections in accordance
with local electrical codes. Use qualified electricians. Use of a separate, dedicated 20 amp circuit is required.
Size wiring to handle indicated load and provide necessary overcurrent protector in circuit (see amperage
requirements on the unit’s serial tag).

WIRING DIAGRAM:

Refer to the wiring diagram for any service work performed on the unit. Should you require service, 
please contact FWE and provide the model and serial number of the unit involved.

-5-

ELECTRICAL

Содержание Air Supremacy Air Screen ASU-9

Страница 1: ...h door closed minimum of one 1 hour Load cabinet with only PRE CHILLED FOOD of 40 F 4 4 C or colder After loading chilled product close door to allow inside temperature to stabilize Unload cabinet close door and press Defrost Icon on the control panel Allow 30 minutes Place trays all the way to the back of unit OPEN DOOR ALARM Close door for 5 minutes and defrost will activate automatically In thi...

Страница 2: ...ly uncrate your unit and check for any possible damage Read this operating manual and instructions Return your Warranty Manufacturer Registration Card Your Manufacturer Registration Card must be returned within 30 days after initial delivery to put warranty into effect Review installation instructions and have your unit s properly installed Make sure all operators understand the contents of this m...

Страница 3: ...LECTRICAL 5 INSTALLATION 6 PERFORMANCE 7 INTENDED USE 7 CABINET FEATURES 7 ELECTRONIC CONTROLS 8 TRANSPORTING 10 OPEN DOOR OPERATION 10 GENERAL CLEANING AND MAINTENANCE 11 SERVICE INFORMATION 12 TROUBLESHOOTING GUIDE 13 REPLACEMENT PARTS 16 WIRING DIAGRAM 18 WARRANTY 19 SERVICE RECORD 20 3 ...

Страница 4: ...eturned to FWE without an RGA Return Goods Authorization Number If damage is discovered call your dealer trucking company FWE Customer Service Department at 815 459 7500 IMPORTANT This merchandise has been thoroughly inspected and carefully packed before leaving our plant Responsibility for its safe delivery was assumed by the carrier at the time of shipment Claims for loss or damage to the conten...

Страница 5: ...15 459 7500 and alert them to the situation 4 Receiver must call the carrier to schedule an inspection of the damaged merchandise within 15 days A Check SERIAL PLATE to be sure the unit is installed on the proper NEMA plug 6 20P on standard unit electrical supply B WARNING This unit is provided with a three pronged grounding plug Be sure that the unit is plugged into a properly grounded outlet to ...

Страница 6: ...PS A The outside carton has already been removed and inspected for damage Remove all packing and strapping material from the exterior and interior of the unit Note Packing material should be saved should there be any damage to unit B Remove the FWE Air Screen from the shipping skid This is done by tilting the unit and rolling it off the skid Do not lay the cabinet down D Tray slides have tabs form...

Страница 7: ...OPERATING PARAMETERS The SCREEN of air is capable of maintaining 40 F 4 4 C temperature or below for an extended period of time up to 180 minutes conditional HOWEVER actual time your ASU 9 will run in this temperature zone depends on many factors such as Room ambient temperature Humidity levels Air disruption such as a hood vent or air return Amount of time unit was allowed to precondition the foo...

Страница 8: ... display G DEFROSTING THE EVAPORATOR COIL Your FWE ASU 9 AIR SCREEN unit offers you four defrost options First is a smart auto defrosting option Smart defrost is the factory default option and requires you to do nothing the defrost cycle is automatic Sensors on the evaporator coil read coil temperature and decide how long and how often your ASU 9 unit requires defrosting Depending on usage and env...

Страница 9: ...ing unit requires regularly scheduled cleaning to keep the finned condenser clean of lint and dust accumulation Keeping the condenser clean allows the ASU 9 unit to operate efficiently use less energy and achieve top performance values The clean condenser light will illuminate approximately every 60 days of run time to remind you its time to care for your ASU 9 unit and clean the condenser coil Re...

Страница 10: ...tray slides racked in the cabinet after trays have been emptied of food product may result in better performance 5 This unit is equipped with an automatic condensate evaporator To prevent water spills leave unit plugged in with door closed after use A recommendation would be to defrost after use as well to free coil from ice build up formed during use 6 Your ASU 9 is equipped with a smart controll...

Страница 11: ...ontain chlorinated solvents Always read the label of the cleaning solutions Check for warnings about use on stainless steel products Repeated use of chlorinated solvents may cause a chemical reaction with the stainless steel which will damage the surface and cause rusting Care should also be taken to avoid splashing the unit with water containing chlorinated cleansers when mopping the floor around...

Страница 12: ...uum any dirt lint and or dust from the finned condenser coil the compressor and other cooling system parts If significant dirt is clogging the condenser fins use brush or compressed air to blow this clear NOTE Care should be taken not to bend any of the condenser fins as this will reduce performance and compressor life Replace louver assembly and screws which hold it in place If the unit is NOT WO...

Страница 13: ...e defrosted or has tripped off due to overload Wait 30 minutes Unit will self reset 3 Condensing unit fails to start hums but 1 Unit may need to be defrosted or has tripped off due to overload trips on overload protector Wait 30 minutes Unit will self reset 2 Improperly Wired Check Wiring Against Diagram 3 Low Voltage Determine Reason Correct 4 Starting Capacitor Defective Determine Reason Replace...

Страница 14: ...estrictions In Cooling Medium Restrictions in Refrigeration System 6 Suction Pressure Too High Check For Possibility Of Misapplication Use Stronger Unit 7 Compressor Too Hot return gas Check Refrigerant Charge fix leak Add If Necessary 8 Compressor Motor Has Winding Shorted Replace Compressor 6 Condensing unit runs but short cycles on 1 Overload Protector See 3 Above 2 Thermostat Differential Set ...

Страница 15: ...ting Angle Remount Relay In Correct Position 3 Line Voltage Too High or Too Low Determine Reason Correct 4 Excessive Short Cycling Determine Reason see 6 above Correct 5 Relay Being Influenced By Loose Vibrating Mounting Remount Rigidly 6 Incorrect Run Capacitor Replace With Proper Capacitor 11 Suction line frosted or sweating 1 Overcharge of refrigerant Correct Charge 2 Evaporator Fan Not Running...

Страница 16: ... and Blower Assembly DESCRIPTION PART NUMBER Evaporator Coil Assembly Z 600 1993 Defrost Element EL DFST AC 1 ASU 220 Defrost Relay RLY 30AMP DPDT 240 Fan Evaporator FAN BLOW 220 6 75 DIA Temperature Probe THERMISTOR PROBE REF Expansion Valve VLV EXP R3A1 BRZ De Ice Switch T STAT DEFROST SL55 Door Switch SWH MAG REED Thermistor Probe PROBE NTC REF 12 Lower Condensing Unit Assembly DESCRIPTION PART...

Страница 17: ... COIL MOUNT DOOR LIFT OFF HINGE FRONT AIR TUNNEL TRAY SLIDE FRONT VENT ACCESS PANEL LOWER ELECTRICAL BOX CONTROLLER CONDENSER FILTER DRIER REAR VENT ACCESS PANEL COMPRESSOR CONDENSER FAN MOTOR DEFROST ELEMENT EVAP COIL DRIP PAN DRIP PAN REAR AIR TUNNEL REAR BUMPER TXV EXPANSION VALVE EVAPORATOR FANS EVAPORATOR FAN ASSEMBLY SERVICE ACCESS PANEL THERMISTOR PROBE COOL DOWN SWITCH COOL DOWN SWITCH TER...

Страница 18: ... 18 FWE ASU 9 AIR SUPREMACY AIR SCREEN WIRING DIAGRAM 06 2012 ...

Страница 19: ... in a Correctional Environment Facilities which is warranted for a period of six 6 months This warranty is for normal usage and does not apply to any product or parts thereof that have been misused altered or where Seller s operating instructions or specific voltage is not observed nor shall this warranty apply to defective products or parts resulting from accident following date of original shipm...

Страница 20: ...________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _______________________________________________________________...

Отзывы: