background image

 

. Safety rules and precautions 

 

Thank you for purchasing the company's high and low voltage 

clamp ammeter. To avoid possible electric shock or personal injury, 

please be sure to strictly observe the safety rules and precautions 

listed in this manual.

 

 

 

Before use, check whether the instrument is in good condition,             
no damage, and forbid to use before the back cover is covered. 
Otherwise, there is danger of electric shock. 

 

In any case, it should pay special attention to safety in use of     

this meter, particularly in measurement of circuitry with more 
than

 

AC100V and above voltages. 

  

If the voltage of tested circuitry has exceeded 600V, it must     
be used by connecting with an insulation rod. 

 

As it is very dangerous of high voltage transmission line, the   

operator must get strict training and the relevant certification 
on high-pressure operation of the state before using this meter 
and making a field test.   

 

It is strictly forbidden to use this meter to test the wire without 

any insulate protection or convergence generatrix. 

 

Please pay attention to marked words and symbols on panel     

or backboard of this meter. 

 

Please do not put or store this meter in the place of high     

temperature,  with  moisture,  with  frozen  dew  or  with  direct 
daylight irradiation for a long time.   

 

Please note the battery polarity when replacing battery, and     

remove  the  battery  if  you  expect  not  to  use  this  meter  for  a 
long time. 

 

It must be operated by qualified staff that has the authorization 

on tearing down or repairing this meter.   

 

Check the housing before using the meter. Check for cracks or 

Содержание ES1000 Series

Страница 1: ...0 ...

Страница 2: ...ns 9 3 Ordinary H L Voltage Clamp Meter Test Display Instruction 10 Ⅶ Basic H L Voltage Clamp Meter Operating Instructions 10 1 Power On Off 11 2 General Test 11 3 PEAK Test 13 4 Data Maintenance 13 5 Data Storage 13 6 Data Reference 14 7 Data Deletion 14 Ⅷ Symbols of Wireless H L Voltage Clamp Meter 14 1 Instrument LCD Symbol Description 14 Ⅸ Receiver Operation 15 1 Power On Off 15 2 Data Recepti...

Страница 3: ...2 5 Data Reference 16 6 Data Deletion 17 Ⅹ Batteries 17 Ⅺ Accessories 17 ...

Страница 4: ...n rod As it is very dangerous of high voltage transmission line the operator must get strict training and the relevant certification on high pressure operation of the state before using this meter and making a field test It is strictly forbidden to use this meter to test the wire without any insulate protection or convergence generatrix Please pay attention to marked words and symbols on panel or ...

Страница 5: ...on according to the indication It suggests that this meter shall be made insulation intensity test at least once every year AC 60kV rms five insulation rods between the two ends The manual has a wireless transmission data type Ⅱ Brief Introduction The H L Voltage Clamp Meter is a high voltage measurement tool composed of a special clamp ammeter equipped with a high voltage insulation rod Inside th...

Страница 6: ...ly used in substations power plants industrial and mining enterprises and testing stations electrical maintenance departments for current detection and field electrical work Insulation rods are light moisture proof high temperature resistant impact resistant bend resistant and highly insulating Ⅲ Electrical Symbols Symbol Meaning Dangerous voltage Risk of electric shock Warning attention safety si...

Страница 7: ...measurement 0 0mA 1200A 50 60Hz Auto Identification 3 Test Accuracy 2 5dgt 4 Sampling Speed About 2 times second 5 Meter Dimension W T H 87mm 37mm 262mm 6 Receiver Dimension W T H 100mm 35mm 204mm 7 LCD Dimension 47mm 28 5mm 8 Wireless Receiver Display Dimension 62mm 44mm 9 Internal Battery DC6V 4 alkaline batteries 7th Wireless Receiver 5 1 5V5 alkaline batteries 10 Meter Total Weight 2 5kg inclu...

Страница 8: ...1 75 31 40 50 15 Wireless Distance 30m 16 Insulating Rod Five section insulation rods 5 meters in total Insulation strength AC60kV rms Parameter with symbol is for the wireless model Ⅴ Outline Structure Base Model Wireless Model Receiver for Wireless Model ...

Страница 9: ...r Indication Wireless Type HOLD Key Wireless Receiver LCD Display Insulation Rod total 5m Ⅵ H L Voltage Clamp Meter Symbols 1 Button Instructions POWER Press the POWER button to turn on the LCD display and enter the normal test mode PEAK Peak hold LOWBATTERY Low power display light HOLD Data retention function wireless model 2 LCD four digit Symbol Display Instructions ...

Страница 10: ...C Alternating current symbol HOLD Data retention DC Direct current symbol 3 Ordinary H L Voltage Clamp Meter Test Display Instruction Status Symbol Instrucion The measured current exceeds the upper limit of the meter When the memory data is full of 100 groups the FULL symbol flashes and data can no longer be stored Data clear symbol displayed during clearing The measured current is 0 1mA ...

Страница 11: ...ay please replace the battery in time Review the stored 08th set of the measured current it s data is 100 6A Ⅶ Basic H L Voltage Clamp Meter Operating Instructions Please check all parts of the meter carefully before usage to see whether there is any damage And make sure no damage before usage According to manual instructions to install the battery Test Operation ...

Страница 12: ...access mode In the data reference mode press the HOLD button and the POWER button to check the data mode Press and hold the HOLD button to return to the normal test mode and then press the POWER button to shut down 2 General Test High voltage extremely dangerous It must be operated by qualified staff that has acquired authority The operator must strictly abide by the safety rules Otherwise there i...

Страница 13: ...ter test it should incline the insulation rod accordingly on drawing in Firstly to tear down the tester and then the insulation rod avoiding the impact of meter to ground surface After the normal start up let the wire be in the middle of the clamp guide area the instrument guide area is perpendicular to the wire push the meter forward to clamp the measured wire and the LCD shows the measurement re...

Страница 14: ...is removed away from the wire on test the test result will be kept consistently suitable for the circuit test on those LCD data hard to be read directly Under the normal testing mode press PEAK button PEAK indication light will be bright enter PEAK testing mode That means the meter will display and automatically keep the maximum value in the test 4 Data Maintenance Under normal testing mode press ...

Страница 15: ... The data when referring to the last set of stored data automatically returns to the first set of data Press and release the POWER button to release the data reference mode and return to the normal test mode 7 Data Deletion In the test mode press and hold the POWER button once to clear all stored data During the data clearing process the dEL symbol is displayed Hold down the HOLD button to clear t...

Страница 16: ... 5 5V this symbol shows please replace the battery in time The measured current of the stored 06th data is 27 6A ⅨReceiver Operation 1 Power On Off Press POWER button to turn on LCD display enter the receive data mode If the LCD display is dark after power on the battery voltage may be low Replace the battery in time After the receiver is turned on for 15 minutes the LCD continues to blink indicat...

Страница 17: ...OLD button once again to relieve data lock returns to data reception mode HOLD symbol disappears 4 Data Storage Under Date Reception mode press HOLD button to maintain data meanwhile the receiver will automatically form serial numbers and memory the current preserved data During the storage MEM symbol will display once by flash The receiver can memory 200 groups of data in case of full storage FUL...

Страница 18: ...ive data mode Ⅹ Batteries Warning In case that the battery s cover board is not well closed it is forbidden to make test Otherwise it is dangerous Pay attention to the polarity of battery in case of damage to the meter Do not mix in the use of new and old batteries 1 When the battery voltage is below 5 5V the meter will display symbol indicating the batteries have no sufficient power content Pleas...

Страница 19: ...used by use The company reserves the right to modify the contents of the user manual If there is any change it will not be notified GuangZhou ZhengNeng Electronics Technology Co Address 2F No 15 Baoshu Road Taihe Baiyun District Guangzhou Guangdong China Toll free call 4000 1515 38 Tel 86 20 36544172 Fax 86 20 37319075 Post 510540 WebSite www znele com ...

Отзывы: