FuturePlus Systems FS2334 Скачать руководство пользователя страница 6

 

6

 

Software License Agreement 

IMPORTANT - 

Please

 read 

this license agreement carefully before opening the media 

envelope.  Rights in the software are offered only on the condition that the customer 
agrees to all terms and conditions of the license agreement. Opening the media 
envelope indicates your acceptance of these terms and conditions.  If you do not agree 
to the licensing agreement, you may return the unopened package for a full refund. 

 

In return for payment for this product, FuturePlus Systems grants the Customer a 
SINGLE user LICENSE in the software subject to the following: 

 

 

ƒ

 

Customer may use the software on any one Agilent mainframe logic analysis system. 

 

Customer may make copies or adaptations of the software. 

 

Customer may not reverse assemble or decompile the software. 

 

 

 

Are allowed for archival purpose only. 

 

When copying for adaptation is an essential step in the use of the software with the logic 
analyzer and/or logic analysis mainframe so long as the copies and adaptations are used in no 
other manner.  Customer has no right to copy software unless it acquires an appropriate license 
to reproduce from FuturePlus Systems.   

 

Customer agrees that it does not have any title or ownership of the software, other than the 
physical media. 

 

 

 

Customer acknowledges and agrees that the software is copyrighted and protected under the 
copyright laws. 

 

Transfer of the right of ownership shall only be done with the consent of FuturePlus Systems. 

 

 

ƒ

 

Customer may not sublicensing the software or distribute copies of the software to the public in 
physical media or by electronic means or any other means without the prior written consent of 
FuturePlus Systems. 

License Agreement 

Use of the software 

Copies and Adaptations 

Ownership 

Sublicensing and Distribution 

Содержание FS2334

Страница 1: ...n DDR2 DIMM HIGH SPEED PROBE FS2334 Users Manual For use with Agilent Technologies Logic Analyzers Revision 1 4 FuturePlus is a registered trademark of FuturePlus Systems Corporation Copyright 2006 Fu...

Страница 2: ...nal Assignments on Probe Pods 9 Signal Threshold Voltage Settings 9 Connecting the DDR2 Probe to the Logic Analyzer 9 Test Points 10 Connecting to your Target System 11 Signal Isolation on the Probe 1...

Страница 3: ...sampling positions with controlled stimulus 24 State Display 26 DDR2 Protocol Checking and Performance Tool FS1140 27 FS1140 Installation and Licensing 27 Loading the FS1140 27 Setting up the FS1140...

Страница 4: ...471 2738 On the web http www futureplus com For Sales and Marketing Support FuturePlus Systems Corporation TEL 719 278 3540 FAX 719 278 9586 On the web http www futureplus com FuturePlus Systems has...

Страница 5: ...charges duties and taxes for products returned to FuturePlus Systems from another country FuturePlus Systems warrants that its software and hardware designated by FuturePlus Systems for use with an i...

Страница 6: ...re Are allowed for archival purpose only When copying for adaptation is an essential step in the use of the software with the logic analyzer and or logic analysis mainframe so long as the copies and a...

Страница 7: ...act FuturePlus Systems Corporation Definitions Logic Analyzer Modules Module A set of logic analyzer cards that have been configured via cables connecting the cards to operate as a single logic analyz...

Страница 8: ...MT s Available Protocol Checking capability VBA license required software Uses Auto Sample Position Set up EyeFinder and Auto Threshold Set up to locate tight DDR2 data valid windows for optimal state...

Страница 9: ...threshold for optimal signal capture The use of Eye Scan can be very helpful in determining where to set these thresholds NOTE The optimal settings may need to be defined either through trial and erro...

Страница 10: ...on for the FS2334 is to have S0 wired to the Clk input which is TP3 wired to TP1 This is done in the factory by soldering a short wire between the 2 test points If CKE0 is to be used as a Clk input th...

Страница 11: ...the FS2334 Connect the FS2334 Headers directly to the logic analyzer pods per the configuration file requirements if not done prior to installing the probe Refer to the General Purpose Probe Signal I...

Страница 12: ...ards configured as one module one timing machine N A FS234_1 Read and Write analysis requires 7 cards across 2 frames configured as 2 logic analyzer state machines Uses FS1136 FS234_3 4 card configura...

Страница 13: ...it 800MT s Data State analysis configuration 4 cards in slots A D B Master FS234_2 Timing analysis 3 card configuration 3 cards in slots A C B Master FS234_3 800MT s Writes only 4 card configuration 4...

Страница 14: ...you must contact the FuturePlus sales department to purchase additional licenses Loading 169xx configuration files and General Purpose Probe Feature When the software has been licensed you are able t...

Страница 15: ...g up a 16900 analyzer Once the FuturePlus software has been installed and licensed follow these steps to import the data and view it From the desktop double click on the Agilent logic analyzer icon Wh...

Страница 16: ...on required is generally available from the spec sheet of the memory device being used or by querying the BIOS of the target system a Number of Chip Selects This is either 1 or 2 based on the whether...

Страница 17: ...DQS8 are contained on an extra Header 14 which will require an additional logic analyzer card in order to probe Decoding DDR Commands No Protocol Decoder is used for timing analysis However symbols ar...

Страница 18: ...r to add another card in all the configurations These bits are available refer to the Appendix if the user wants to modify the existing configuration files and or add an additional logic analysis card...

Страница 19: ...ple Position Set up function can be a more accurate means to set the sampling position for each bit used in the State analysis but this requires using known continuous data patterns of exclusive Reads...

Страница 20: ...yte labels make easier to both measure and set 3 At 400MHz clock speed the 16900 analyzer in this configuration will display both the State and TimingZoom version of the State Clock signal CommandClk...

Страница 21: ...e TimingZoom labels for the command clock chip selects and DQS0 Write Command CK2_TZ S0_TZ DQS8 0_TZ 0 and the data bus labels for Writes Data63 32_R Fand Data31 0_R F in the waveform view Scroll the...

Страница 22: ...to differences in the DIMM layout and individual differences in the DRAMs on the DIMM Compute the average of the times between the rising edge of Write Command CK2_TZ for each byte associated with the...

Страница 23: ...k to step 1 and trigger on your known data pattern again Check your Write Command listing for the State data values across multiple Write bursts They should be close to or equal to the known data writ...

Страница 24: ...set the sampling speed to 300MHz and slow the system DDR clock down to 333MHz 667MT s and run Eyefinder on the Command Address Control signals with the S0 clock qualification Set the sampling speed an...

Страница 25: ...reshold as required to establish correct Threshold settings valid eye openings and sample positions for these signals Move the sample positions for all the Read_Data labels rising and falling to the c...

Страница 26: ...as Read Write etc so you don t have to refer to the DDR chip data sheet to see what command is being executed These decoded values are displayed by setting the display base in the listing window or t...

Страница 27: ...FS1140 software will provide measurements of the Data Window eye width on a bit by bit basis across all Timing Zoom data in the trace file additionally it will identify those signals with the smallest...

Страница 28: ...system in order to insure proper decode of the captured logic analyzer trace file Selecting the Set up button from the window provides a form for this information There are 4 DDR2 DIMM bus parameters...

Страница 29: ...count is based on the errors selected in the Setup Also included in this display is information on the Read Write and Data activity occurring during the captured trace file Errors This section of the...

Страница 30: ...criteria in this window and then select whether the data windows to be identified should be equal to greater than or equal to or less than or equal to that value All Data bits during any burst capture...

Страница 31: ...31...

Страница 32: ...nd Ground 3 4 NC NC 5 6 NC Ground 7 8 D0 CKE1 20K ohm to Ground 9 10 Ground Ground 11 12 D1 CKE0 20K ohm to Ground 13 14 Ground Ground 15 16 D2 A15 20K ohm to Ground 17 18 Ground Ground 19 20 D3 A14 2...

Страница 33: ...55 56 D12 A6 20K ohm to Ground 57 58 Ground Ground 59 60 D13 A4 20K ohm to Ground 61 62 Ground Ground 63 64 D14 A3 20K ohm to Ground 65 66 Ground Ground 67 68 D15 A1 20K ohm to Ground 69 70 Ground Gr...

Страница 34: ...Ground 17 18 Ground Ground 19 20 D3 NC4 20K ohm to Ground 21 22 Ground Ground 23 24 D4 S1 20K ohm to Ground 25 26 Ground Ground 27 28 D5 ODT0 20K ohm to Ground 29 30 Ground Ground 31 32 D6 CAS 20K ohm...

Страница 35: ...o Ground 61 62 Ground Ground 63 64 D14 A2 20K ohm to Ground 65 66 Ground Ground 67 68 D15 See TP matrix 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Grou...

Страница 36: ...18 Ground Ground 19 20 D3 DQ1 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DM0 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQS0n 20K ohm to Ground 29 30 Ground Ground 31 32 D6 DQS0 20K ohm to Gr...

Страница 37: ...0K ohm to Ground 61 62 Ground Ground 63 64 D14 DQ9 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DM1 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Groun...

Страница 38: ...8 Ground Ground 19 20 D3 DQ14 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ10 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQ15 20K ohm to Ground 29 30 Ground Ground 31 32 D6 DQ11 20K ohm to Gro...

Страница 39: ...hm to Ground 61 62 Ground Ground 63 64 D14 DQ18 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DQ23 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Ground...

Страница 40: ...18 Ground Ground 19 20 D3 DQ29 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ25 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DM3 20K ohm to Ground 29 30 Ground Ground 31 32 D6 DQS3n 20K ohm to Gr...

Страница 41: ...hm to Ground 61 62 Ground Ground 63 64 D14 CB5 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DM8 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Ground Gr...

Страница 42: ...ohm to Ground 17 18 Ground Ground 19 20 D3 CB6 20K ohm to Ground 21 22 Ground Ground 23 24 D4 CB2 20K ohm to Ground 25 26 Ground Ground 27 28 D5 CB7 20K ohm to Ground 29 30 Ground Ground 31 32 D6 CB3...

Страница 43: ...n 20K ohm to Ground 61 62 Ground Ground 63 64 D14 No connection 20K ohm to Ground 65 66 Ground Ground 67 68 D15 No connection 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 7...

Страница 44: ...o Ground 17 18 Ground Ground 19 20 D3 DQ33 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DM4_DQS13 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQS4n 20K ohm to Ground 29 30 Ground Ground 31 32 D6...

Страница 45: ...Q45 20K ohm to Ground 61 62 Ground Ground 63 64 D14 DQ41 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DM5_DQS14 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground...

Страница 46: ...o Ground 17 18 Ground Ground 19 20 D3 DQ47 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ43 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQ52 20K ohm to Ground 29 30 Ground Ground 31 32 D6 DQ48 2...

Страница 47: ...60 D13 DQ50 20K ohm to Ground 61 62 Ground Ground 63 64 D14 DQ55 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DQ51 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Gro...

Страница 48: ...to Ground 17 18 Ground Ground 19 20 D3 DQ57 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DM7_DQS16 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQS7n 20K ohm to Ground 29 30 Ground Ground 31 32 D6...

Страница 49: ...13 SDA 20K ohm to Ground 61 62 Ground Ground 63 64 D14 SA1 20K ohm to Ground 65 66 Ground Ground 67 68 D15 SCL 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77...

Страница 50: ...7 18 Ground Ground 19 20 D3 DQ1 20K ohm to Ground 21 22 Ground Ground 23 24 D4 No connection 20K ohm to Ground 25 26 Ground Ground 27 28 D5 No connection 20K ohm to Ground 29 30 Ground Ground 31 32 D6...

Страница 51: ...round 61 62 Ground Ground 63 64 D14 DQ9 20K ohm to Ground 65 66 Ground Ground 67 68 D15 No connection 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Ground...

Страница 52: ...ohm to Ground 17 18 Ground Ground 19 20 D3 DQ14 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ10 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQ15 20K ohm to Ground 29 30 Ground Ground 31 32 D6...

Страница 53: ...ohm to Ground 61 62 Ground Ground 63 64 D14 DQ18 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DQ23 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Ground...

Страница 54: ...hm to Ground 17 18 Ground Ground 19 20 D3 DQ29 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ25 20K ohm to Ground 25 26 Ground Ground 27 28 D5 CB3 20K ohm to Ground 29 30 Ground Ground 31 32 D6 CB6...

Страница 55: ...ohm to Ground 61 62 Ground Ground 63 64 D14 CB5 20K ohm to Ground 65 66 Ground Ground 67 68 D15 CB1 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Ground...

Страница 56: ...round 17 18 Ground Ground 19 20 D3 DQ33 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ43 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQ47 20K ohm to Ground 29 30 Ground Ground 31 32 D6 No connec...

Страница 57: ...ohm to Ground 61 62 Ground Ground 63 64 D14 DQ41 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DQ42 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Groun...

Страница 58: ...to Ground 17 18 Ground Ground 19 20 D3 DQ58 20K ohm to Ground 21 22 Ground Ground 23 24 D4 DQ62 20K ohm to Ground 25 26 Ground Ground 27 28 D5 DQ52 20K ohm to Ground 29 30 Ground Ground 31 32 D6 DQ48...

Страница 59: ...ohm to Ground 61 62 Ground Ground 63 64 D14 DQ55 20K ohm to Ground 65 66 Ground Ground 67 68 D15 DQ51 20K ohm to Ground 69 70 Ground Ground 71 72 NC NC 73 74 Ground Ground 75 76 NC Ground 77 78 Ground...