Future light PRO Slim PAR-18 TCL Скачать руководство пользователя страница 24

00064609.DOC, Version 1.1

24/31

Master/Slave operation

The master/slave operation enables that several devices can be synchronized and controlled by one master
device.

On the rear panel of the device you can find an XLR jack and an XLR plug, which can be used for
connecting several devices.

Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX-cable. Connect the OUT jack
with the IN plug of the next device.

Set the desired mode for the master-device (see chapter Control Board). Set the DMX address 001 for all
slave-devices.

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.

The occupation of the connection-cables is as follows:

Cable

Pin

International

Brown

Live

L

Blue

Neutral

N

Yellow/Green

Earth

The earth has to be connected!

If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.

The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

Lighting effects must not be connected to dimming-packs.

The device is equipped with a lockable power input connector. Plug in the power cord and turn it to the right
until it locks. Plug the power cord into a grounded electrical outlet that matches the rated voltage of the
machine.

On the rear panel, there is a socket (Power Out). Connect the output with the mains input of the next fixture
until all fixtures are connected.

Please note: 

A maximum of 8 devices may be linked together. After every 8 devices, the fixtures must have

a renewed connection with the power mains.

Содержание PRO Slim PAR-18 TCL

Страница 1: ...Copyright Nachdruck verboten Reproduction prohibited F r weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL PRO Slim PAR 18 TCL...

Страница 2: ...NSTRUCTIONS 18 OPERATING DETERMINATIONS 20 DESCRIPTION OF THE DEVICE 21 Features 21 Overview 21 INSTALLATION 22 Overhead rigging 22 DMX512 control 23 Master Slave operation 24 Connection with the main...

Страница 3: ...r laden EINF HRUNG Wir freuen uns dass Sie sich f r einen FUTURELIGHT PRO Slim PAR 18 TCL entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem...

Страница 4: ...gen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten a...

Страница 5: ...gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen u...

Страница 6: ...use Zweiter Montageb gel f r sicheren Halt beim Aufstellen Arretierm glichkeit an den B geln durch gro e Metallfl gelschrauben Reine Konvektionsk hlung ber K hlrippen keine L fter Funktionen statische...

Страница 7: ...eite Aufh ngung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufh ngung kein Teil der Installation herabfallen kann W hrend des Auf Um und Abbaus ist der unn tige Aufenthalt im B...

Страница 8: ...er t ber einen geeigneten Haken an Ihrem Traversensystem Sichern Sie das Ger t bei berkopfmontage immer mit einem geeigneten Sicherungsseil Es d rfen nur Sicherungsseile und Schnellverbindungsglieder...

Страница 9: ...n DMX Eingang des n chsten Ger tes an Verbinden Sie immer einen Ausgang mit dem Eingang des n chsten Ger tes bis alle Ger te ange schlossen sind Achtung Am letzten Ger t muss das DMX Kabel durch einen...

Страница 10: ...er in eine geerdete Schutzkontaktsteckdose ein An der R ckseite der Ger te befindet sich eine Einbaubuchse Power Out Verbinden Sie den Ausgang mit dem Netzanschluss des n chsten Ger tes bis alle Ger t...

Страница 11: ...hmen Modus Wert Funktion P 1 Internes Programm 1 P 2 Internes Programm 2 P 3 Internes Programm 3 P 4 Internes Programm 4 P P 5 Musikgesteuert 7 Farben Dr cken Sie die MODE Taste bis das LED Display S_...

Страница 12: ...kan le nicht mit anderen Ger ten berlappen damit der FUTURELIGHT PRO Slim PAR 18 TCL korrekt und unabh ngig von anderen Ger ten in der DMX Verbindung funktioniert Werden mehrere PRO Slim PAR 18 TCL au...

Страница 13: ...33 46 20 27 S ROT 0 GR N 100 BLAU zunehmend 71 90 47 5A 28 35 S ROT 0 GR N abnehmend BLAU 100 91 110 5B 6E 36 43 S ROT zunehmend GR N 0 BLAU 100 111 130 6F 82 44 51 S ROT 100 GR N 0 BLAU abnehmend 131...

Страница 14: ...rkurve 102 152 66 98 40 60 S Nicht lineare Dimmerkurve 1 153 203 99 CB 60 80 S Nicht lineare Dimmerkurve 2 204 255 CC FF 80 100 S Nicht lineare Dimmerkurve 3 5 Kanal Modus Steuerkanal 1 Rot Decimal He...

Страница 15: ...imal Hexad Percentage S F Eigenschaft 0 255 00 FF 0 100 F Gr n 0 aus 255 100 gr n Steuerkanal 4 Blau Decimal Hexad Percentage S F Eigenschaft 0 255 00 FF 0 100 F Blau 0 aus 255 100 blau 3 Kanal Modus...

Страница 16: ...runreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden Im Ger te...

Страница 17: ...fon LED Typ 3 W TCL Anzahl der LEDs 18 Abstrahlwinkel 18 Ma e BxTxH 100 x 255 x 295 mm Gewicht 3 kg Maximale Umgebungstemperatur Ta 45 C Max Leuchtentemperatur im Beharrungszustand Tc 75 C Mindestabst...

Страница 18: ...ven in this manual we are sure that you will enjoy this device for a long period of time Unpack your device SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can...

Страница 19: ...ion of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle t...

Страница 20: ...evice must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstor...

Страница 21: ...Four different dimmer curves adjustable Sound control via built in microphone Microphone sensitivity adjustable via rotary control on the top panel Comfortable addressing and setting via Control Board...

Страница 22: ...proved by a skilled person once a year Procedure The device should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including...

Страница 23: ...TO LIFE Before taking into operation for the first time the installation has to be approved by an expert DMX512 control The wires must not come into contact with each other otherwise the devices will...

Страница 24: ...N Yellow Green Earth The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has...

Страница 25: ...can simply set the starting address or run the internal programs Browse through the main menu by pressing MODE Press ENTER in order to select the desired menu You can change the selection by pressing...

Страница 26: ...m which the FUTURELIGHT PRO Slim PAR 18 TCL will respond to the controller Please be sure that you don t have any overlapping channels in order to control each FUTURELIGHT PRO Slim PAR 18 TCL correctl...

Страница 27: ...7 S RED 0 GREEN 100 BLUE increasing 71 90 47 5A 28 35 S RED 0 GREEN decreasing BLUE 100 91 110 5B 6E 36 43 S RED increasing GREEN 0 BLUE 100 111 130 6F 82 44 51 S RED 100 GREEN 0 BLUE decreasing 131 1...

Страница 28: ...02 152 66 98 40 60 S Non linear dimmer curve 1 153 203 99 CB 60 80 S Non linear dimmer curve 2 204 255 CC FF 80 100 S Non linear dimmer curve 3 5 channel mode Control channel 1 Red Decimal Hexad Perce...

Страница 29: ...cimal Hexad Percentage S F Feature 0 255 00 FF 0 100 F Green 0 off 255 100 green Control channel 4 Blue Decimal Hexad Percentage S F Feature 0 255 00 FF 0 100 F Blue 0 off 255 100 blue 3 channel mode...

Страница 30: ...and any safety problems have to be removed Disconnect from mains before starting maintenance operation DANGER TO LIFE We recommend a frequent cleaning of the device Please use a soft lint free and moi...

Страница 31: ...via built in microphone LED type 3 W TCL Number of LEDs 18 Beam angle 18 Dimensions WxDxH 100 x 255 x 295 mm Weight 3 kg Maximum ambient temperature Ta 45 C Maximum housing temperature TC steady stat...

Отзывы: