![Future light DMB-150 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/future-light/dmb-150/dmb-150_user-manual_2352080035.webp)
00078029.DOC, Version 1.1
35/52
The fixture’s base enables to be mounted in
two ways.
The Moving-Head can be placed directly on
the stage floor or rigged in any orientation
on a truss without altering its operation
characteristics (see the drawing).
Make sure that the Omega-holder is always
in line with the truss structure when installing
the device vertically.
For overhead use (mounting height >100
cm), always install an appropriate safety
bond.
You must only use safety bonds complying
with DIN 56927, quick links complying with
DIN 56927, shackles complying with DIN EN
1677-1 and BGV C1 carbines. The safety
bonds, quick links, shackles and the cabines
must be sufficiently dimensioned and used
correctly in accordance with the latest industrial safety regulations (e. g. BGV C1, BGI 810-3).
Please note:
for overhead rigging in public or industrial areas, a series of safety instructions have to be
followed that this manual can only give in part. The operator must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Install the safety bond by inserting the quick link in the hole on the bottom of the base. Pull the safety bond
over the trussing system etc. Insert the end in the quick link and tighten the fixation screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
1
2
3
4
(1)
Omega-holder
(2)
Clamp
(3)
Safety-rope
(4)
Quick-lock fastener