background image

Page 11 of 17 // Installation Instructions - EAD3

Installation Instructions

5 - Setting Mechanism Limits

The mechanism's IN position is factory set at 152mm [6"]. This is the mechanism furthest most IN 
position and can only be adjusted outwards. Adjustment of the IN Switch buffers is very sensitive, so 
should always be adjusted in small increments for safety reasons. All IN position adjustments must be 
carried out using the rubber buffer ONLY and NOT the IN Switch itself.

IN Switch - 

This must 

NOT be adjusted.

Wall Plate Buffers.

IN Switch Buffer

OUT Limit Switch Slider.

To adjust the IN position:
1.  Wind the two rubber buffer stops mounted on the wall plate IN as far as possible.
2.  Wind the rubber In Switch Buffer in or out in small increments to adjust where the contacts  hits the In 

Switch.

3.  Once the desired IN position has been achieved, the two rubber buffer stops on the wall plate must then be 

wound out to contact the upper arm rest when the bracket is in the IN position.

To adjust the OUT position:
1.  Loosen the 2 x M5 Nuts on the left of the mechanism shown below to release the OUT Limit switch.
2.  Slide the OUT Limit Switch 

UP

 to 

RAISE

 the OUT position or 

DOWN

 to 

LOWER

 the OUT position.

3.  Once the desired OUT position has been achieved, re-tighten the 2 x M5 Nuts loosened in step 1.

Содержание EAD3

Страница 1: ...Installation Instructions Issue 002 Electric Advance and Drop TV Wall Mount EAD3 ...

Страница 2: ...does not operate normally or has been dropped Contact the original installer manufacturer to arrange repair or return WARNING To reduce the risk of burns fire electric shock or injury to persons 1 Clean only with a dry cloth and always unplug any electrical items being used in conjunction with this product before cleaning Product Safety Disclaimer IMPORTANT SAFETY INSTRUCTIONS BELOW WARNING Failur...

Страница 3: ...ick start Guide 6 Installation Instructions 7 1 Mechanism Positioning 7 2 Fixing To The Wall 8 3 Screen Mounting 9 4 Screen Position Adjustment 10 5 Setting Mechanism Limits 11 6 Cable Management 12 Mechanism Control 13 1 General 13 2 Infrared IR Operation 14 3 Contact Closure Operation 15 4 RS232 Operation 16 Contact Information 17 ...

Страница 4: ...pplied parts Any electrical or other environmental work external to your Future Automation mechanism including power cuts surges or lightning strikes Additional items not supplied by Future Automation although they may have been supplied together by the retailer Any 3rd party software products controlling your mechanism Any transfer of ownership Warranty is provided only to the initial purchaser C...

Страница 5: ...d with RJ45 Connector 4 6 Screen Fixings Pack Multi pack of Nuts Bolts and Washers 2 Control Box Size and Style May Vary 3 Infrared IR Remote Control Package Contents 1 EAD3 Mechanism 1 1 Wall Plate 1 2 Top Cover 1 3 Bottom Cover 1 4 Screen Mount Uprights 1 5 Down Position Switch 1 6 Up Position Switch 1 7 Up Position Switch Adjuster 1 8 Main Uprights 1 4 1 4 1 7 1 1 1 5 1 6 1 2 1 3 1 8 1 8 ...

Страница 6: ... tag attached stating the correct connecting socket on the control board e g AC1 DC2 Image 2 Below 5 Plug the green connector into the corresponding socket on the control board This plug is handed and will only connect correctly one way Do NOT force the connector into the socket this can cause serious damage to the control board and mechanism 6 Route the wiring loom out of the end of the control b...

Страница 7: ...laid flat offer the screen onto the Screen Uprights and measure from the bottom of the screen to the bottom of the wall plate to determine the mechanisms position on the wall Note the screen should be mounted as high up on the mechanism as possible to reduce the amount of wall plate that remains visible behind the screen in the DOWN position 2 The screen must start a minimum of 50mm 2 0 above any ...

Страница 8: ...x M5 fixings shown below to access the rear fixing holes 2 Fix the mechanism to the wall using suitable fixings Not Provided in as many mounting holes as possible Note The highlighted fixing holes shown below MUST be used in any installation 3 The mechanism may need to be powered out to a mid position to access some central fixing holes See Mechanism Control section of the installation instruction...

Страница 9: ...er you will need to swap the left and right Mount Uprights 1 4 over 2 On the back of each Mount Upright 1 4 will be three Mount Bobbins Once the uprights are attached to the back of the screen measure the horizontal distance between the these Bobbins and adjust the Main Uprights 1 8 still attached to the EAD3 so the keyholes fixings on these are the same horizontal distance apart as the Mount bobb...

Страница 10: ...e screen and Uprights left or right along the stainless steel Mount Bars shown below The s lots in the Screen Uprights 1 4 allow for vertical position adjustment by loosening screen fixings and raising or lowering screen to the desired position 2 Tighten of the lower 2 fixings on the rear of Main Uprights 1 8 will lock off horizontal adjustments 3 The top fixings on the rear of the Main Uprights 1...

Страница 11: ...imit Switch Slider To adjust the IN position 1 Wind the two rubber buffer stops mounted on the wall plate IN as far as possible 2 Wind the rubber In Switch Buffer in or out in small increments to adjust where the contacts hits the In Switch 3 Once the desired IN position has been achieved the two rubber buffer stops on the wall plate must then be wound out to contact the upper arm rest when the br...

Страница 12: ...cables should ideally enter exit the mechanism through the cable cut cut out in the center of the Wall Plate 1 1 3 After entering from the Cable Cut out in the Wall Plate 1 1 cables should be routed along the underside of the Upper Arms following the dotted line below and fixed using cable ties secured to the tie blocks supplied 250 150 100 C L SYM All Cables must be correctly managed and secured ...

Страница 13: ...third party safety mechanism Replacing Mechanism Batteries The standard Future Automation Infrared IR remote control required x2 AAA batteries to operate These are provided with the mechanism in the Accessories Pack These batteries can be replaced as the per the image below Control Box Inputs Mains Voltage Input Input Confirmation LED IR Input Jack 3 5mm EmergencyStopConnector Contact Closure RJ45...

Страница 14: ...d IR Operation This Mechanism can be controlled via the supplied 14 button Infrared IR Remote Control pair with the supplied Infrared IR lead and sensor The mechanism s functions can be controlled by plugging the Infrared IR lead and sensor into the 3 5mm IR Input Jack shown on the General Mechanism Control page Confirmation of Infrared IR input will be shown by a single flash of the large green L...

Страница 15: ... Connector attached to a length of CAT5 Type 568A or 568B cable The mechanism s functions can be controlled by plugging this into the RJ45 port on the mechanism control board then shorting pins 1 8 on this connector as shown in the Contact Closure Input Table below Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box as ...

Страница 16: ...ing Details Baud Rate 9600 Stop Bit 1 Parity None Databits 8 RJ11 RJ25 Func 9 PIN Serial Colour PIN 1 TX RX PIN 2 Blue PIN 3 GROUND PIN 5 Green PIN 4 GROUND PIN 5 Red PIN 6 RX TX PIN 3 White 4 RS232 Operation This Mechanism can be controlled via RS232 utilising a 6 Pin RJ11 RJ25 connector OR 9 Pin Serial connector attached to a length of 6 core cable The mechanism s functions can be controlled by ...

Страница 17: ... 44 0 1438 833577 Email info futureautomation co uk Office Hours Mon Fri 8 00 to 17 30 GMT Saturday Sunday Closed North American Office Address Enterprise Park 127 Venture Drive Dover NH 03820 Phone 1 603 742 9181 Email info futureautomation net Office Hours Mon Fri 7 00 to 17 00 EST Saturday Sunday Closed Contact Information ...

Отзывы: