7
Bandwidth Setup
IMPORTANT NOTE:
Do not connect the device to the power supply when the power supply is already on.
SW4
BANDWIDTH
1
2
3
4
BANDWIDTH (Hz)
▲
▼
▼
▼
100
▼
▲
▼
▼
1,000
▼
▼
▲
▼
10,000
2
▼
▼
▼
▲
25,000
3
▼
▼
▼
▼
50,000
4
SW4 can be used to set the bandwidth from 100 Hz to
50,000 Hz. Confirm the bandwidth is appropriate for
your application.
2
Only for sensitivity of 1.0 mV/V or greater
3
Only for sensitivity of 1.5 mV/V or greater
4
Only for sensitivity of 2.0 mV/V or greater
Note:
Increasing the bandwidth
can increase the overall noise.
4