Wiring en Display examples for Voice cable

 · USOC Phone Cable Properly Wired

Pass appears on the display indicating a properly wired cable. 

The pin numbers on the top row and bottom row are the same indicating proper 

continuity.

 · USOC Cross Wired Phone Cable Properly Wired

A cross wired cable reverses the connection at one end of the cable. Pins 1-6 

cross over to pins 6-1, pins 2-5 cross over to pins 5-2 and pins 3-4 cross over to 

pins 4-3. Cross wired cables are often used between the wall port nd phone.  

Pass and Rev appear on the display indicating a properly wired cross wired cable.

The pin numbers on the bottom row indicate the corresponding reversal to the 

pin members on the top row.

 · USOC Phone Cable with Shorted and Open Pair

The pair on pins 3-4 is shorted and the pair on pins 1-6 is open. Fail, Short and 

Open appear on the display indicating a defective cable. The pins with wiring 

errors will flash. The dash lines below pins 3-4 indicate a shorted pair. The blank 

space under pins 1-6 ndicate an open pair.

DATA

Warning: Exposure to voltage can damage the Signaltester RJ-F. Immediately dis-

connect the cable under test is Voltage warning appears on the display. Make sure 

the vable is not connected to any device that can supply voltage before retesting. 

Do not connect two different cables into the Voice (RJ11/RJ12) and Data (RJ45) 

test ports at the same time. The cables will interact with each other and alter test 

results.

Testing a Data Patch Cable terminated with RJ45 Connector

1.  Press ON/OFF button to turn on the tester. Press the Data button  to select 

the data wire set function.

2.  Connect one end of the cable under test to the RJ45 port of the tester.

3.  Connect the onter end of the cable under test to the RJ45 port of the remote.

4.  Interpret the results using the Wiring and Display examples for Data further 

in this manual.

Testing an Installed Data Cable

1.  Connect a known good patch cable to the wall port or patch panel of the 

cable being tested.

2.  Connect the other end of the patch cable to the RJ45 port on the tester.

3.  Connect another known good patch cable to the RJ45 port on the remote.

4.  Connect the other end of the patch cable to the wall port or patch panel at 

the other end of the cable being tested.

Содержание 450.68C

Страница 1: ...naltester RJ F to a live circuit Exposure to voltage can damage the tester Do not modify or try to repair the tester No serviceable parts are inside Do not use the tester in a wet or damp environment...

Страница 2: ...on it Exposure to voltage can damage the tester If this warning appears immediately disconnect the cable from the tester J X over Appears when the tester detects a properly wired cross over cable K Op...

Страница 3: ...have no twist ing on the pairs Using the Tone Generator to trace a phone line It is necessary to use the Signalprobe RJ F 1 Connect the cable under test to the RJ11 RJ12 port on the tester 2 Press the...

Страница 4: ...3 4 indicate a shorted pair The blank space under pins 1 6 ndicate an open pair DATA Warning Exposure to voltage can damage the Signaltester RJ F Immediately dis connect the cable under test is Voltag...

Страница 5: ...ss the Cycle button to select the desired pins Refer to sequence chart for explanation of the pin selection When tracing a cable run from the tone generator to the end of the cable applying the tone o...

Страница 6: ...in numbers on the bottom row indicate the corre sponding cross over to the pin numbers on the top row T568B Data Cable with Split Pairs There is a split between the pairs on pins 3 6 and 4 5 Fail and...

Страница 7: ...ers used on coax cables will prevent the tone from passing 1 Connect the cable under test to the F connector on the tester 2 Press the ON OFF button to turn on the Signaltester RJ F than press the Vid...

Страница 8: ...ntinuity The cable is good and passes the test ID3 signifies that Remote Identifier number 3 is being used to terminate the cable The flashing o s on the bottom of the display indicate the tester is r...

Страница 9: ...length 305m Min Cable length for split pair de tection 0 5m Max Coax cable Resistance 100 max DC Dimensions 152x61x34 Weight 230g Futech is a registered brand of Laseto NV Belgium Futech declares that...

Отзывы: