15
⑥
Connect the I/O cable to the amplifier.
⑦
Connect the I/O cable to the I/O signal device.
Refer to Section 2-6,
“Connecting the I/O Signal”. (→ Page 15)
⑧
Connect the external measuring device (to output voltage).
Refer to Section 8-1,
“Connecting an External Measuring Device”. (→ Page 38)
⑨
Connect the power supply.
Refer to Section 2-7,
“Connecting the Power Supply”. (→ Page 18)
2-6 Connecting the I/O Signal
<<What is the input signal?>>
The input signal means a signal input to the amplifier from an external device such as a molding
machine or ejector machine.
Trigger signal Required to start measurement. Upon input of the trigger signal,
“zero point resetting” is
performed. Input the trigger signal under the condition with no pressure loaded to the sensor.
Unless there is any specific reason, connect the
“mold closing complete signal”.
* It takes about 0.1 second for zero point resetting. If the injection start signal is used as a trigger, zero point
resetting may not be finished in time and accordingly normal measurement may not be performed.
Clear Alarm signal Connected to clear the alarm signal being output from the amplifier. Connect the signal as
needed.
* The alarm signal can be cleared automatically by specifying the time in the software settings. (
→ Page 23)
If automatic clear at the specified time causes no operational problem, the connection of the Clear Alarm
signal can be omitted.
<<What is the output signal?>>
The output signal means a signal output from the amplifier to an external device such as a molding
machine or ejector robot.
Alarm signal
An alarm signal is output when the monitoring range defined by software is exceeded.
This signal is used to check for defective items and control external devices such as to stop
the molding machine.
* Alarm monitoring can be set for eight channels individually but the alarm output signal is one for all
channels.