![FUTABA FX40 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/futaba/fx40/fx40_instruction-manual_2351421045.webp)
45
<Model Basic Setting Procedure>
$3LWFKWR58'PL[LQJFXUYH1RUPDO
8VHWKHKRYHULQJV\VWHPDQGVHWWKLVFXUYHWR
PDWFKWDNHRIIDQGODQGLQJDQGYHUWLFDOFOLPEDW
DFRQVWDQWVSHHG
*For this curve, use the initial setting [Linear] curve type and
adjust the left and right rates in the [Separate] mode.
%3LWFKWR58'PL[LQJ,GOHXS
8VHWKLVFXUYHLQ
º
VWDOOWXUQORRSDQGUROOLQJ
VWDOOWXUQDQGDGMXVWLWVRWKHIXVHODJHLVIDFLQJ
VWUDLJKWDKHDGZKHQKHDGLQJLQWRWKHZLQG
*For this curve, [Linear] curve type can be used and the entire
curve can be lowered with the [Offset] button.
&3LWFKWR58'PL[LQJ+ROG
7KLVIXQFWLRQLVVHWVRWKDWWKHIXVHODJHLVIDFLQJ
VWUDLJKWDKHDGDWVWUDLJKWOLQHDXWRURWDWLRQ7KH
SLWFKRIWKHWDLOURWRUEHFRPHVQHDUO\
º
*For this curve, [Linear] curve type can be used and the entire
curve can be lowered with the [Offset] button.
ŏ2WKHUVHWWLQJV
7KHPL[LQJFKDUDFWHULVWLFDWSLWFKRSHUDWLRQFDQ
EHDGMXVWHG$QDFFHOHUDWLRQ$&/5IXQFWLRQDQG
GHFHOHUDWLRQ'&/5IXQFWLRQZKLFKWHPSRUDULO\
LQFUHDVHVDQGGHFUHDVHVWKHPL[LQJDPRXQWFDQ
EHVHW
6ZDVK0L[FRUUHFWVDLOHURQHOHYDWRUDQG
pitch interaction
The swash mix function is used to correct the
swash plate in the aileron (roll) direction and
elevator (cyclic pitch) corresponding to each
operation of each condition.
7KURWWOHPL[LQJVHWWLQJ
RPM loss caused by swash operation at aileron
or elevator operation can be corrected with the
Throttle Mix function of the Model Menu. How
clockwise and counterclockwise torque is applied
when pirouetting can also be corrected.
10. Gyro sensitivity and mode switching
The gyro sensitivity and mode switching
function can be set for each condition.
ŏ1RUPDO FRQGLWLRQ KRYHULQJ *\UR VHQVLWLYLW\
PD[LPXP
ŏ,GOH XS ,GOH XS 7KURWWOH KROG *\UR
VHQVLWLYLW\PLQLPXP
ŏ+RZHYHU DW DXWR URWDWLRQ RI D WDLOGULYHQ
KHOLFRSWHU WKLV IXQFWLRQ PD\ QRW KDYH DQ\
DIIHFWDWKLJKJ\URVHQVLWLYLW\
11. Throttle cut setting
Throttle cut provides an easy way to stop the
HQJLQHE\ÀLSSLQJDVZLWFKZLWKWKHWKURWWOHVWLFN
at idle. The action is not functional at high throttle
to avoid accidental dead sticks. The switch’s
location and direction must be chosen, as it defaults
WR18//
*With throttle stick at idle, adjust the cut position
until the engine consistently shuts off, but throttle
linkage is not binding. When finished, touch the
“Throttle Cut” button to exit.
2WKHUVSHFLDOPL[LQJV
ŏ3LWFKWR1HHGOHPL[LQJ
7KLVPL[LQJLVXVHGZLWKHQJLQHVZLWKDFRQVWUXFWLRQ
ZKLFKDOORZVQHHGOHFRQWUROGXULQJÁLJKWIXHODLU
PL[WXUHDGMXVWPHQW$QHHGOHFXUYHFDQEHVHW
7KHQHHGOHVHUYRULVHFKDUDFWHULVWLFVDWWKURWWOH
VWLFNDFFHOHUDWLRQGHFHOHUDWLRQRSHUDWLRQFDQEH
DGMXVWHG$FFHOHUDWLRQIXQFWLRQ
ŏ)XHOPL[WXUHIXQFWLRQ
7KLVPL[LQJLVXVHGLQQHHGOHDGMXVWPHQWRIHQJLQHV
ZKLFKXVHDIXHOPL[WXUHFRQWUROFDUEXUHWRU
ŏ*RYHUQRUPL[LQJ
7KLVPL[LQJLVXVHGZKHQD*9JRYHUQRULVXVHG
8SWRUDWHVVSHHGVFDQEHVZLWFKHGIRUHDFK
FRQGLWLRQ