background image

11/01/2014

30  |  HQ Fusion User Manual

www.HandiQuilter.com

Keypad Test

The Keypad test verifies that the HQ

24

 Fusion is 

reading the front and rear handlebar buttons as 

they are pressed. When a key is pressed, a beep 

 

will be heard and the name of the key that is 

pressed will appear in the box on the screen.

 

Press X

 to close this window or 

Back

 to return to 

the Diagnostics Menu.

Speed

35% 

Needle Position

Manual

Regulated

80

Presets

35% 

50% 
70% 

REC

Diagnostics

X

Diagnostics

Keypad Test

Passing Test:

The name of the key is shown below.

Failing Test:

No name or the wrong name below

Press one of the handlebar keys.

Keys Up

Motor Speed Sensor Test

The Speed test helps you determine whether

or not there is a problem with the HQ Fusion speed

sensor. Before performing this test, remove the 

bobbin case and the top thread. 

Press the Start button and the machine needle 

will begin moving at 1200 stitches per minute. The 

white box will show a number that should stabilize 

at 100 if the sensor is functioning properly. Pressing 

Start again will stop the machine.

Press X

 to close this window or 

Back

 to return to 

the Diagnostics Menu.

 

Speed

35% 

Needle Position

Manual

Regulated

80

Presets

35% 

50% 
70% 

REC

Diagnostics

X

Diagnostics

Speed Sensor Test

Passing Test:

   The value stabilizes at 100.

Remove bobbin case and top thread.

Clear all objects from the needle

area. Press the start button

0

Calibrate Tension Test

You should only calibrate the tension under the 

direction of Handi Quilter technical support. 

While calibrating the tension, you will be asked to 

do the following:

 

1. 

Remove the tension knob. 

2. 

Gently press the spring against the tension discs 

while not compressing the spring. 

3. 

While holding the spring in place, press Reset. 

4. 

When calibration is complete, replace the 

tension knob.

Speed

35% 

Needle Position

Manual

Regulated

80

Presets

35% 
50% 

70% 

REC

Tension Calibration

X

Diagnostics

Reset

Calibration should only be done under the

guidance of a Handi Quilter Technician.

Carefully remove tension knob.

Gently press spring against tension

discs but do not compress the spring.

While holding spring in place,

press the Reset button.

Replace the tension knobs.

256

Alarms

The HQ fusion has two  useful alarms: thread-break alarm and overspeed alarm. Touch the Alarm button 

and then select either the thread-break alarm or the overspeed alarm enable or disable the alarm.

Содержание QM32469

Страница 1: ...HANDI QUILTER 24 INCH LONGARM Designed by a Quilter for Quilters USER MANUAL QM32469 VERSION 3 0...

Страница 2: ...e as Oiling Your Machine to Loading a Quilt to Making Perfect Feathers We ve got videos to watch pdf files to print out for reference and forums for asking questions Remember if you ever have question...

Страница 3: ...di Feet 11 Installation Thread Mast 12 Installation Laser Stylus 12 Laser Stylus Safety and Use Guidelines 13 Threading the Machine 14 Optional Horizontal Spool Pin 15 Bobbin and Thread Tension Adjust...

Страница 4: ...e temperatures 9 Use the HQ Fusion only for its intended use as described in this manual 10 Use only attachments recommended by the manufacturer 11 Use only the power cord set provided by Handi Quilte...

Страница 5: ...roat 9 625 inches x 24 00 inches Rate Voltage Power Consumption 90 to 264 Vac 47 to 63 Hz 400 Watts LED Lights 24 Watts 5 Vdc Hook System Custom Manufactured Rotary Large Bobbin Bobbin Type Class M Mo...

Страница 6: ...nt Diagram C 30 Spool Pin 1 31 Electronic Control Pod 32 Laser Stylus Power Connector 33 Serial Port for Stitch Regulator 34 Rear Handle Bar Serial Port 35 Rear Threaded Handle Holes 36 Accessory Powe...

Страница 7: ...r connector 4 The remaining length of cable comes back under the Power Pod from the Rear Encoder Assembly behind the machine and into the 9 pin serial port of the machine IMPORTANT If the machine is t...

Страница 8: ...unplugged from the electrical outlet All power to the machine must be turned off when installing the back handles Failure to do so can result in damage to the machine To install the rear handles The r...

Страница 9: ...ches for your machine The main power switch is at the rear of the machine and another power switch is at the front of the machine below the right handlebar for added convenience The machine is turned...

Страница 10: ...the needle all the way up into the needlebar until it can go no farther 4 Carefully tighten the needle bar clamp screw U U CAUTION Over tightening the needle clamp screw will result in damaged threads...

Страница 11: ...e Handi Feet 1 Remove the foot that is on the mount by using the 2 5mm hex wrench to loosen the mounting screw far enough that you can slide the foot off of the mount 2 Slide the desired foot onto the...

Страница 12: ...lt causing thread tension problems Installing the Laser Stylus To attach the laser stylus to the top of the machine 1 Locate the laser stylus guide post the laser holder and the laser stylus 2 Locate...

Страница 13: ...hen it is plugged into the HQ Fusion Be sure the laser is attached to the HQ Fusion and pointed downward toward the table before connecting it to the port Never point it in a direction that would proj...

Страница 14: ...from back to front back hand wheel side to needle side see Detail 1 below NOTE The purpose of this guide is to prevent loops of thread coming off the thread cone from going into the top tension as a k...

Страница 15: ...sion where the top tension is always tight and the tension discs are never open Therefore the thread must be pulled up or flossed between the tension discs or it will stay outside the discs and float...

Страница 16: ...this installation Use the latch lever only for removal of the bobbin case U U CAUTION Turn off the power switch while inserting the bobbin case or anytime the hands are near the needle area To bring t...

Страница 17: ...te adjustments and test again Check your bobbin tension every time you switch to a new bobbin Easy Set Tension It is easy to set the top tension on the HQ Fusion with the Easy Set Tension Puckering ga...

Страница 18: ...nal oiling is not necessary on the HQ Fusion except when the machine is taken to a service technician for routine maintenance and cleaning The bobbin basket assembly however needs regular lubricating...

Страница 19: ...de Press the Manual button to set the machine to Manual mode The button turns light yellow to indicate it is in Manual mode Press the Speed plus button to increase the manual mode motor speed and pres...

Страница 20: ...s light yellow to indicate it is in Regulated mode To select Precision or Cruise regulated mode After switching to Regulated mode alternate between the Precision and Cruise stitch regulation options b...

Страница 21: ...machine 4 inch baste one stitch every four inches of movement of the machine After selecting the basting stitch setting begin quilting by pressing the Start button on the handlebars As you move the m...

Страница 22: ...Bright Cool Warm Dim Light Ring Bright Cool lighting will appear more blue while warm lighting will appear more red U U CAUTION Looking directly into the UV lights or prolonged exposure to the UV ligh...

Страница 23: ...Alarm screen To estimate how much thread are on a bobbin place a full bobbin in the machine Then press the red Record button under the heading Bobbin Thread Capacity Quilt as usual until the bobbin r...

Страница 24: ...k directly at Purple UV LEDs Long term exposure to UV is not advisable Dim Main Light Cool Dim Light Rin As you quilt the remaining bobbin thread value decreases to show how much thread remains on the...

Страница 25: ...ound and a message appears on the display Speed 10 Timers X 3 0 Manual Regulated The second bottom timer enables you to track how much time you spend on a quilt project When you begin a new project pr...

Страница 26: ...etc to avoid unwanted stitching in your quilt or your hands If you leave the HQ Fusion in Precision mode with the green indicator on and do not move the machine for two minutes the system will time o...

Страница 27: ...n Needle Position Regulated 80 Settings Diagnostics Syste 195 System Information The information on this screen identifies the electronics board revision number as well as the firmware revision number...

Страница 28: ...to return to the Diagnostics Menu Speed 35 Needle Position Manual Regulated 80 Presets 35 50 70 REC Diagnostics X Diagnostics Motor Sensor Test Passing Test Rugular pulsing beeps as you rotate the han...

Страница 29: ...ft and right Slowly push left and right Press X to close this window or Back to return to the Diagnostics Menu Y Motion Sensor Test Use the Y Motion Sensor test to verify functionality of the Y stitch...

Страница 30: ...ow or Back to return to the Diagnostics Menu Speed 35 Needle Position Manual Regulated 80 Presets 35 50 70 REC Diagnostics X Diagnostics Speed Sensor Test Passing Test The value stabilizes at 100 Remo...

Страница 31: ...ch 40 stitches per second when at full speed If you want to use stitch regulation to achieve twelve precise stitches per inch you shouldn t move the machine faster than about three to four inches per...

Страница 32: ...rom 5 to 100 In Regulated mode press and hold this button to decrease the stitches per inch SPI ranging from 4 to 22 SPI HQ Stitch Regulation To use regulation mode press the Regulated button turns ye...

Страница 33: ...stitches back to the desired length By moving the machine slower the stitches get shorter and can build up on top of each other breaking the thread or making it extremely difficult to remove the stit...

Страница 34: ...ft required for stitch formation Typically a larger needle will solve the problem however it has been found that certain smaller sizes of needles as well as the use of ball pointed needles solve some...

Страница 35: ...e nut at the base of the hopping foot shaft Adjust to the proper height Note When tightening the nut on the hopping foot shaft be careful not to tighten so tight that it rotates the bar The tension is...

Страница 36: ...tating the tension knob clockwise Improper threading Refer to threading diagram and threading instructions Thread Backlash Corrective Measure Bobbin thread tangles within the bobbin case tangles and w...

Страница 37: ...ely 12 to 15 inches has been pulled off with the ends pinched together Cotton threads are particularly susceptible to dry rot or wet rot which makes thread brittle Do not use poor quality thread or th...

Страница 38: ...Wrong type of needle Use needles recommended by Handi Quilter Using the wrong needle with a smaller shank diameter causes many problems For example a system 1738 or 287WH needle with a shank diameter...

Страница 39: ...pair facility or such other point or place that may be designated by HQ All other costs including cost of freight and shipment for repair under this warranty shall be the customer s costs This warrant...

Страница 40: ...the original warranty or ninety days from the date of shipment of a repaired or replaced Product whichever is longer HQ s entire liability for any defective Product shall in no event exceed the purcha...

Страница 41: ...dress _____________________________________________________________________________________________ City __________________________________________________________ State _____________ Zip ____________...

Страница 42: ...11 01 2014 42 HQ Fusion User Manual www HandiQuilter com This page was intentionally left blank...

Страница 43: ...ulation a How to use Cruise stitch regulation a How to use Precision stitch regulation a How to use the front and rear handlebars a How to use the laser pointer stylus and the included pantograph a Re...

Страница 44: ...11 01 2014 44 HQ Fusion User Manual www HandiQuilter com This page was intentionally left blank...

Страница 45: ...s reserved Printed in the U S A PRINTED 11 01 2014 HQ Fusion is part of the family of innovative quilting products from Handi Quilter Handi Quilter Inc 501 N 400 W North Salt Lake UT 84054 1 877 MY QU...

Отзывы: