background image

FusionServer XH321 V6 Server Node 
Technical White Paper 

5 Hardware Description 

 

2022-03-18 

18 

 

Silkscreen 

Indicator/Butt
on 

Description 

network port 

Connection 
status indicator 
of the 
management 
network port 

 

Off: The network port is not connected. 

 

Steady green: The network port is connected 
properly. 

PSU indicator 

 

Off: No power is supplied. 

 

Blinking green at 1 Hz: 

 

The input is normal, and the server is in the 
standby state. 

 

The input is overvoltage or undervoltage. 

 

The PSU is in deep hibernation mode. 

 

Blinking green at 4 Hz: The firmware is being 
upgraded online. 

 

Steady green: The power input and output are 
normal. 

 

Steady orange: The input is normal but there is no 
output. 

NOTE 

The possible causes of no power output are as follows: 

 

Power supply overtemperature protection 

 

Power output overcurrent or short-circuit 

 

Output overvoltage 

 

Short-circuit protection 

 

Device failure (excluding failure of all devices) 

 

Steady red: The output overcurrent occurs. 

 

5.1.3 Ports   

Port Positions 

Figure 5-3

 

Ports on the front panel 

 

 

Содержание FusionServer XH321 V6

Страница 1: ...FusionServer XH321 V6 Server Node Technical White Paper Issue 02 Date 2022 03 18 xFusion Digital Technologies Co Ltd...

Страница 2: ...usion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this document may...

Страница 3: ...0 5 2 Processors 20 5 3 Memory 21 5 3 1 DDR4 Memory 21 5 3 1 1 Memory Identifier 21 5 3 1 2 Memory Subsystem Architecture 22 5 3 1 3 Memory Compatibility 23 5 3 1 4 DIMM Installation Rules 24 5 3 1 5...

Страница 4: ...ications 34 6 1 Technical Specifications 34 6 2 Environmental Specifications 37 6 3 Physical Specifications 38 7 Software and Hardware Compatibility 39 8 Safety Instructions 40 8 1 Security 40 8 2 Mai...

Страница 5: ...level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard...

Страница 6: ...hite Paper About This Document 2022 03 18 vi Change History Issue Date Description 02 2022 03 18 This is the second official release Updated 6 1 Technical Specifications and A 4 Sensor List 01 2021 12...

Страница 7: ...up to four XH321 V6 server nodes in a 2U chassis The XH321 V6 delivers supreme performance and high storage density in limited space through innovative design It is easy to manage and maintain XH321...

Страница 8: ...assisted Intel Virtualization Technology Intel VT allows operating system OS to better use hardware to address virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly...

Страница 9: ...ntegrated Unified Extensible Firmware Interface UEFI improves setup configuration and update efficiency and simplifies fault handling Aggregated management of node management ports Intel Execute Disab...

Страница 10: ...supported improving the efficiency of the power supply system Efficient voltage regulator down VRD power supplies for boards minimize the energy loss from DC DC power conversion Intel Intelligent Powe...

Страница 11: ...ysical Structure 2022 03 18 11 3 Physical Structure Figure 3 1 XH321 V6 physical structure 1 Air duct 2 Screw in RAID controller card 3 Supercapacitor 4 Processor heat sinks 5 TPM TCM 6 Memory modules...

Страница 12: ...V6 Server Node Technical White Paper 3 Physical Structure 2022 03 18 12 11 I O board 12 OCP 3 0 network adapter 13 Management network port board 14 PCIe riser module 15 Power supply unit PSU 16 M 2 SS...

Страница 13: ...cal Structure 2022 03 18 13 4 Logical Structure Figure 4 1 XH321 V6 logical structure CPU 1 is connected to two NVMe SSDs or two pass through PCIe riser cards through PCIe x8 CPU 2 is connected to the...

Страница 14: ...through a high speed connector and the mainboard is connected to drives through the middle module to support different local storage configurations The LBG R Platform Controller Hub PCH is integrated...

Страница 15: ...scription 2022 03 18 15 5 Hardware Description 5 1 Front Panel 5 2 Processors 5 3 Memory 5 4 Storage 5 5 Network 5 6 I O Expansion 5 7 PSUs 5 8 Boards 5 1 Front Panel 5 1 1 Appearance Figure 5 1 Front...

Страница 16: ...indicator 4 iBMC direct connect management port indicator 5 Data transmission status indicator of the management network port 6 Connection status indicator of the management network port 7 PSU indica...

Страница 17: ...indicator is steady yellow you can press this button to power on the device UID button indicator The UID button indicator helps identify and locate a device UID indicator Off The device is not being...

Страница 18: ...he standby state The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady green The power input and output are n...

Страница 19: ...e type iBMC direct connect management port debugging serial port USB Type C NOTE The USB 2 0 protocol is supported 1 Uses a USB Type C cable to connect a local PC or mobile phone to the server node iB...

Страница 20: ...ation Positions The XH321 V6 nodes are installed in the 2U4 slots of an X6000 V6 chassis which can house a maximum of 4 XH321 V6 nodes Figure 5 4 Installation positions When installing a server node e...

Страница 21: ...tion 2022 03 18 21 Figure 5 5 Processor positions 5 3 Memory 5 3 1 DDR4 Memory 5 3 1 1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module...

Страница 22: ...DDR4 5 Maximum memory speed 2933MT S 3200MT S 6 Memory latency parameters CL tRCD tRP W 20 20 20 Y 21 21 21 AA 22 22 22 7 DIMM type R RDIMM L LRDIMM 5 3 1 2 Memory Subsystem Architecture A server prov...

Страница 23: ...he memory can be used with the third generation Intel Xeon Scalable Ice Lake processors The maximum memory capacity supported by all processor models is the same Total memory capacity Total capacity o...

Страница 24: ...4 DIMM Installation Rules Observe the following when configuring DDR4 memory modules Install memory modules only when corresponding processors are installed Do not install LRDIMMs and RDIMMs in the sa...

Страница 25: ...emory modules To maximize performance balance the total memory capacity between the installed processors and to load the channels similarly whenever possible Observe the memory module installation rul...

Страница 26: ...DR4 memory module installation guidelines 2 processors 5 3 1 6 Memory Protection Technologies The following memory protection technologies are supported ECC Memory Mirroring Memory Single Device Data...

Страница 27: ...gion ADC SR Adaptive Double Device Data Correction Multiple Region ADDDC MR 1 5 4 Storage 5 4 1 Drive Configurations Table 5 5 Drive configuration Configuration Maximum Drives Drive Management Mode Bu...

Страница 28: ...the Compatibility Checker to determine the components to be used For details about the RAID controller card see V6 Server RAID Controller Card User Guide A pass through card provides a channel for co...

Страница 29: ...bility and connection Four PCIe 4 0 slots are supported including one dedicated PCIe slot for a RAID controller card one dedicated FLEX I O slot for an OCP 3 0 NIC and two standard PCIe slots Contact...

Страница 30: ...cant CPU socket are unavailable Table 5 6 PCIe slot description PCIe Slot CPU PCIe Stand ards Conn ector Widt h Bus Widt h Port No Root Port B D F Slot Size Screw in RAID contro ller card CPU2 PCIe 4...

Страница 31: ...so the slot 1 supports the multi host feature the x16 bus of the slot is connected to two processors through two x8 cables 5 7 PSUs The node supports one PSU The server supports AC or DC PSUs If the n...

Страница 32: ...Slimline3 x8 high speed connector SLIMLINE3 CPU2 J4 7 M 2 riser card connector M 2 RISER X8 J14 8 Slimline2 x8 high speed connector SLIMLINE2 J84 9 4 pair x8 high speed connector J18 10 6 pair x8 high...

Страница 33: ...Paper 5 Hardware Description 2022 03 18 33 CPU1 J11 21 GE management network port board connector GE CONN J27 22 VROC key connector SOFT RAID KEY J3 a 23 OCP 3 0 network adapter connector OCP CONN J10...

Страница 34: ...Supports one or two processors Third generation Intel Xeon Scalable Ice Lake processors Built in memory controller and eight memory channels per processor Built in PCIe controller supporting PCIe 4 0...

Страница 35: ...kb vmware com s article 1033696 Configure syslog For details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive applications th...

Страница 36: ...C iBMC direct connect management port debugging serial port One RJ45 management network port One PSU socket Built in ports One 2 x M 2 SSD expansion port Video card An SM750 video chip with 32 MB disp...

Страница 37: ...n three months 8 to 85 Storage humidity within six months 8 to 80 Storage humidity within one year 20 to 75 Maximum humidity change rate 20 h Altitude 3050 m 10006 44 ft When the server configuration...

Страница 38: ...hs in power off state with data stored Maximum preservation duration of HDDs 6 months in unpacked packed and powered off state The maximum preservation duration is determined according to the preserva...

Страница 39: ...sic middleware software and hardware The slight differences of the application software middleware basic software and hardware may cause performance inconsistency between the application layer and tes...

Страница 40: ...rforming high voltage operations and driving a forklift This is a class A product which may cause radio interference in a domestic environment Take protective measures before operating this product in...

Страница 41: ...watches and jewelry Figure 8 2 shows conductive objects that must be removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Put your...

Страница 42: ...y for dedicated servers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a devi...

Страница 43: ...s the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per person Organization Weight kg lb European Committee for Standardiz...

Страница 44: ...stable running of the device The iBMC allows screenshots and videos to be created when the system breaks down facilitating cause analysis of the system breakdown The iBMC offers screen snapshots and v...

Страница 45: ...synchronizes network time to optimize time configuration The iBMC supports domain name system DNS and Lightweight Directory Application Protocol LDAP to implement domain management and directory servi...

Страница 46: ...5 A11 2020 CISPR 32 2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 EN 55032 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ET...

Страница 47: ...10 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 RoHS BS EN IEC 63000 2018 ErP Commission Regulation EU 424 2019 China CCC GB 17625 1 2012 GB 4943 1 2011 GB T 9...

Страница 48: ...Vendor code two characters that is the code of the processing place 4 Year and month two characters The first character indicates the year Digits 1 to 9 indicate years 2001 to 2009 respectively Lette...

Страница 49: ...3 0 Networ k Adapter s Number of RAID Controll er Cards Fan Configu ration CPU Configuratio n Maximum Temperat ure 0 drives 8 2 0 0 8080 205 W P 270 W 35 C P 205W 35 C 2 0 1 8080 205 W P 270 W 35 C P...

Страница 50: ...Table A 3 Operating temperature limitations server with 24 x 2 5 SAS SATA drives Drive configu ration Number of Standar d PCIe Cards Number of OCP 3 0 Networ k Adapter s Number of RAID Controll er Car...

Страница 51: ...rds Number of OCP 3 0 Networ k Adapter s Number of RAID Controll er Cards Fan Configu ration CPU Configuratio n Maximum Temperatu re 16 drives 24 2 0 0a 8080 185 W P 205 W 35 C P 185W 35 C 2 1 0a 8080...

Страница 52: ...ID controller card PCH Temp PCH bridge temperature Component in position U55 on the mainboard CPUN Core Rem CPU core temperature Mainboard N indicates the CPU number The value is 1 or 2 CPUN DTS Diffe...

Страница 53: ...ainboard SYS_5V_STBY Mainboard 5 0 V voltage Component in position U72 on the mainboard SYS_5V_RESV Component in position U106 on the mainboard SYS_VPP_ABCD Mainboard CP1 VPP voltage Component in posi...

Страница 54: ...rd CPUN Status CPU status CPUN N indicates the CPU number The value is 1 or 2 CPUN Memory DIMM status Memory module corresponding to CPU N N indicates the CPU number The value is 1 or 2 PwrOk Sig Drop...

Страница 55: ...Button UID button status Mainboard RTC Battery RTC battery status An alarm is generated when the voltage is lower than 1 V RTC battery on the mainboard RAID Status RAID controller card health status R...

Страница 56: ...Time hopping N A NTP Sync Failed NTP synchronization failure and recovery events N A Host Loss System monitoring software BMA link loss detection N A IB Temp IB NIC temperature IB card N N indicates t...

Страница 57: ...V6 Server Node Technical White Paper AAppendix 2022 03 18 57 Sensor Description Component CPUN VCCANA CPUN VCCANA voltage Mainboard N indicates the CPU number The value is 1 or 2 IO Temp I O card tem...

Страница 58: ...manage the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox...

Страница 59: ...sting PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI syste...

Страница 60: ...stored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet cha...

Страница 61: ...current AES Advanced Encryption Standard New Instruction Set ARP Address Resolution Protocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard mana...

Страница 62: ...ss memory DVD digital video disc E ECC error checking and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS...

Страница 63: ...ement controller IC Industry Canada ICMP Internet Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers...

Страница 64: ...media access control MMC module management controller N NBD next business day NC SI Network Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect E...

Страница 65: ...erial Advanced Technology Attachment SCM supply chain management SDDC single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial managemen...

Страница 66: ...UDIMM unbuffered dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bu...

Отзывы: