FusionServer 2298 V5 Server
Technical White Paper
5 Hardware Description
2022-06-25
23
Tool
Type
Quantity
Description
PSUs, ensure that the rated power
of the PSUs is greater than that of
the server.
⚫
If only one PSU is used,
Predicted PSU Status
cannot be
set to
Active/Standby
on the
iBMC WebUI.
Serial port
RJ45
1
Default operating system serial
port used for debugging. You can
also set it as the iBMC serial port
by using the iBMC command.
NOTE
The port uses 3-wire serial
communication interface, and the
default baud rate is 115,200 bit/s.
Management
network port
1000BASE-T
1
Used for server management.
NOTE
The management network port is a
GE port that supports 100 Mbit/s and
1000 Mbit/s auto-negotiation.
VGA port
DB15
1
Used to connect a display
terminal, such as a monitor or
KVM.
USB 3.0 port
USB 3.0
2
Used to connect to a USB device.
NOTICE
Before connecting an external USB
device, check that the USB device
functions properly. The server may
operate abnormally if an abnormal
USB device is connected.
5.3 Processor
⚫
The server supports one or two processors.
⚫
If only one processor is required, install it in socket
CPU1
.
⚫
The same model of processors must be used in a server.
⚫
Contact your local sales representative or use the
components to be used.
According to Intel's statement, the processors in overclocking mode may cause instantaneous
thermal throttling on certain OSs. The thermal throttling, however, does not affect the
processor performance and reliability.