INSTALLATION, CONT
’
D: BOLTING UNITS TOGETHER / ELEC. RATINGS / FIELD ACCESS BOX
4. Bolting Units Together (Not All Cases)
Bolt units together at lower base as indicated.
•
Remove front and rear panels (no screw removal
required) to drill clearance hole through end panel
and into unit it is being attached to.
•
End panel is shown transparent for illustrative
purposes.
•
Use SCC
-
supplied screws for adjoinment.
5. Electrical Ratings
•
See
SERIAL LABEL LOCATION &
INFORMATION LISTED / TECH INFO &
SERVICE
section in this manual for instructions on
attaining electrical information for your case.
---
Model GHPF356LB
---
---
Model GHPF356LB
---
Field Access / Electrical Box
Model GHPF456LB.5882 Shown / Model GHPF456LB
Has Field Access Box In Same Location
Field Access Box
Ballast Box
6. Field Access Box / Ballast Box / 4 x 4 Box
•
Field access box with ballasts (for LED lights)
may be either at rear or at underside of unit (as
shown in illustrations below).
---
Model GHPF456LB.6165
---
Field Access Box
Ballast Box